Mr. Ross Moore Director of Regulatory Affairs Oklo Inc.
3190 Coronado Dr.
Santa Clara, CA 95054
SUBJECT:
OKLO INC. - U.S. NUCLEAR REGULATORY COMMISSION STAFF FEEDBACK AND OBSERVATIONS REGARDING WHITE PAPER APPROACH TO SEISMIC DESIGN CATEGORIZATION AND SITE CHARACTERIZATION (EPID NO. L-2022-LRO-0048)
Dear Mr. Moore:
By letter November 3, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No.: ML23307A221), Oklo Inc. (Oklo) submitted a white paper (WP),
Approach to Seismic Design Categorization and Site Characterization, for the U.S. Nuclear Regulatory Commission (NRC) staffs review. This WP describes Oklos approach to seismic design categorization and site characterization that would be used to support deployment of Oklos Aurora powerhouse. As part of the WP submittal, Oklo also provided specific questions that it would like the NRC staff to address in its feedback.
On January 18, 2024 (ML24032A149) the NRC staff met with Oklo to discuss the NRC staffs preliminary feedback and observations on the WP. The enclosure to this letter provides the NRC staffs feedback and observations for Oklo to consider as part of any future licensing submittal that may address this topic.
The enclosure to this letter contains proprietary information.
When separated from the enclosure, this document is DECONTROLLED.
February 29, 2024
R. Moore If you have questions regarding this matter, please contact Donna Williams at (301) 415-1322 or via email at Donna.Williams@nrc.gov.
Sincerely, William Jessup, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 99902095
Enclosure:
As stated Signed by Jessup, William on 02/29/24
Package: ML24036A298 Letter: ML24036A305
Enclosure:
ML24036A306 NRR-106 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA RES/DE/SGSEB:BC NAME DWilliams DGreene LBauer DATE 02/06/2024 02/13/2024 02/28/2024 OFFICE NRR/DANU/UAL1:BC NAME WJessup DATE 02/29/2024