Kairos Power LLC, Changes to Hermes 2 Preliminary Safety Analysis Report (PSAR) Chapter 3
ML24031A139
Person / Time
Site: Hermes  File:Kairos Power icon.png
Issue date: 01/30/2024
From:
Kairos Power
To:
Office of Nuclear Reactor Regulation
Shared Package
ML24031A137 List:
References
KP-NRC-2401-009
Download: ML24031A139 (1)


Text

KP-NRC-2401-009 Changes to Hermes 2 PSAR Chapter 3 (Non-Proprietary)

Preliminary Safety Analysis Report Design of Structures, Systems, and Components Kairos Power Hermes 2, Units 1 and 2 3-37 Revision 0 SSC Name Safety Classification Seismic Design Quality Program SAR Section Plant Area Intermediate Heat Exchanger Non-safety related Local Building Code Not Quality-Related 5.1.1 SR area Primary Loop Piping System Non-safety related Local Building Code Not Quality-Related 5.1.1 SR area Primary Loop Thermal Management Non-safety related Local Building Code Not Quality-Related 5.1.1 SR area Reactor Coolant Safety-related N/A Quality-Related 5.1.1 SR area Anti-Siphon Feature Safety-related SDC-3 Quality-Related 5.1.1 SR area Intermediate Heat Transport System Intermediate Salt Pumps Non-safety related Local Building Code Not Quality Related 5.2 NSR area Intermediate Piping System Non-safety related Local Building Code Not Quality Related 5.2 SR and NSR area Superheater Non-safety related Local Building Code Not Quality Related 5.2 NSR area Intermediate Loop Auxiliary Heating Subsystem Non-safety related Local Building Code Not Quality Related 5.2 SR and NSR area Intermediate Inert Gas Subsystem Non-safety related Local Building Code Not Quality Related 5.2 SR and NSR area Intermediate Inert Gas Subsystem Rupture Disks Safety-related SDC-3 Quality Related 5.2 NSR area Intermediate Coolant Inventory Management Subsystem Non-safety related Local Building Code Not Quality Related 5.2 SR and NSR area Intermediate Coolant, Chemistry Control Subsystem Non-safety related Local Building Code Not Quality Related 5.2 SR and NSR area Highlighted changes are part of a previously submitted change package (ML23355A194)