ML24017A013

From kanterella
Jump to navigation Jump to search
NRC Update - NUPIC General Membership Meeting January 22-23, 2024 Clearwater Fl
ML24017A013
Person / Time
Issue date: 01/17/2024
From: Yamir Diaz-Castillo, Fitzgerald M, Greg Galletti
NRC/NRR/DRO/IQVB
To:
References
Download: ML24017A013 (13)


Text

NRC Update NUPIC General Membership Meeting January 22-23, 2024 Clearwater, FL Greg Galletti, Yamir Diaz-Castillo, & Michael Fitzgerald Quality Assurance & Vendor Inspection Branch Office of Nuclear Reactor Regulation

Recent & Upcoming NRC Inspections 2

Recent:

Namco ILAC Observation (Brazil)

Thermo Fisher Henry Pratt Company Rosemount (NUPIC Observation)

Hanna Cylinders Upcoming:

KHNP - Safeguards Information Consolidated Power Supply Westinghouse Columbia Fuel Cycle Facility NuScale Standard Design Approval Application QA Implementation FY24 has QA Implementation and Protection of SGI Inspections planned, in addition to routine Vendor QA Inspections.

NRC Vendor Inspections & Findings 3

Part 21 Violations:

Section 21.21(a)(1) - Thermo Fisher Failed to evaluate a deviation to identify defects associated with substantial safety hazards as soon as practicable.

Appendix B Nonconformances:

Criterion IV, Procurement Document Control, and Criterion VII, Control of Purchased Material, Equipment, and Services - Henry Pratt Company Did not invoke the applicable regulatory, technical, and quality requirements in the procurement documents for safety-related components and services.

Did not perform an assessment of suppliers to verify the adequacy of their quality controls.

Criterion XVI, Corrective Action - Namco Failed to promptly identify and correct conditions adverse to quality.

Unresolved Item (URI):

10 CFR 21.51(a)(1) - Henry Pratt Company

VIP Plan - 2023 Annual Self-Assessment 4

IQVBs Vendor Inspection Program (VIP) plan establishes an overall approach, including goals, priorities, performance metrics, and resources management strategies.

Annual Self-Assessment 2023 Self-Assessment was published in November 2023 (ML23290A222)

VIP Plan and Annual Self-Assessments are available on the NRCs website.

https://www.nrc.gov/reactors/new-reactors/how-we-regulate/oversight/quality-assurance/vendor-insp/vendor-insp-prog-plan.html

VIP Plan - 2023 Annual Self-Assessment 5

FY2023 Violations & Nonconformances Completed 22 Oversight Activities in FY23:

18 Vendor Inspections 3 Observations 1 Audit Issued four violations &

12 nonconformances.

Mistras Services 6

NRC inspection performed on March 6-10, 2023.

Evaluated nondestructive examination services provided for safety-related equipment.

Inspection Report (ML23151A458)

Resulting enforcement actions included:

Two Violations (SL IV) for Part 21 Notifications One Nonconformance against Criteria I

Department of Justice (DOJ) Prosecution of Mistras Personnel On October 18, 2023, DOJ issued a press release announcing that two men pled guilty for their roles in creating false calibration certificates in a matter within the jurisdiction of the NRC.

Both helped create and transmit final testing reports to the owners of the plants which, among other things, contained calibration certificates for the equipment used.

Both created numerous false calibration certificates for AE testing equipment, and 15 of these false certificates were sent a total of 29 times to nuclear plant owners as part of final testing reports required by the NRC. The falsified calibration certificates were discovered in 2021 during an NUPIC audit.

Both are scheduled to be sentenced on Jan. 25, 2024. Each faces a maximum penalty of five years in prison.

Mistras Services 7

Office of Investigation Report 1-2022-003 (ML23340A106)

Resulting enforcement action - 1 apparent violation to:

10 CFR 50.5(a)(2), Deliberate misconduct Criterion XVII, Quality Assurance Records Criterion XII, Control of Measuring and Test Equipment Mistras has requested Alternative Dispute Resolution

ANSYS Vendor Inspection 8

Vendor Inspection performed June 26-30, 2023.

Evaluated software development and support services provided for safety-related services.

Inspection Report documents (ML23237B258):

Inadequate Part 21 procedures and actions related to notification to the Commission and Purchasers.

Company failed to establish a quality assurance program that met the applicable provisions of Appendix B to 10 CFR Part 50. Specifically, procedures failed to document the policies, procedures, and instructions of a quality assurance program which complies with Appendix B.

Resulting enforcement actions included:

Two Violations (SL IV) for Part 21 Notifications Two Nonconformances against Criteria II & XVI NRC received a response from ANSYS on October 10, 2023 (ML23285A168), in which ANSYS stated that they are a provider of commercial grade software products and does not accept any responsibility for Part 21 reporting.

NUPIC led a team of nuclear industry organizations in a meeting with ANSYS on November 17, 2023.

NRC is awaiting a revised response from ANSYS.

NRC Observation During the Rosemount Audit 9

Two NRC inspectors observed NUPICs audit of Rosemount from December 4-8, 2023.

Members of the audit team did not appear to be knowledgeable in the areas being audited.

Some members of the audit team appeared to lack a questioning attitude.

NUPIC auditors did not identify the issue with independence of internal audits until suggested by the NRC staff.

Auditors covering areas of their own work during internal audits.

Auditors auditing areas where they have direct responsibility.

Regulatory Guide (RG) 1.28 10 RG 1.28 Revision 6 was published on September 7, 2023 (ML23177A002)

Endorses Part I & II requirements in NQA-1-2017, NQA-1-2019, and NQA-1-2022 subject regulatory positions.

Majority of regulatory positions from Revision 5 still applicable in Revision 6.

New regulatory positions:

Direct users to use Revision 1 of NEI 14-05A Subpart 2.2 - "Etching should not be used on nickel alloys, weld areas, or sensitized areas of stainless steel.

Subpart 5.5 - "When the referenced or invoked code or standard becomes superseded or canceled, licensees or applicants need to submit their proposed alternative for NRC review and approval, as appropriate, for continued use of the code or standard or a proposed alternative."

Draft RIS - Required Assessment of DOE Labs 11 Developed a Regulatory Issue Summary (RIS) to clarify the agencys regulatory position on the required assessment of U.S. Department of Energy Laboratories by licensees, applicants, and suppliers.

60 days public comment period closed on December 5, 2023.

No comments received.

Currently working to issue the RIS by Spring 2024.

9th Vendor Workshop on Vendor Oversight 12 The workshops provide an open forum for exchanging information regarding oversight of the supply of components, and materials to both new and operating nuclear power plants.

Scheduled for Thursday June 13, 2024, in Baltimore, MD.

Currently coordinating presentation topics and presenters with NUPIC/industry. If you have any feedback or suggestions, please contact Michael Fitzgerald.

Michael.Fitzgerald@nrc.gov (301) 415-0420

13 Michael Fitzgerald Reactor Operations Engineer (301) 415-0420 Michael.Fitzgerald@nrc.gov Yamir Diaz-Castillo Reactor Operations Engineer (301) 415-2228 Yamir.Diaz-Castillo@nrc.gov