ML23321A207
| ML23321A207 | |
| Person / Time | |
|---|---|
| Site: | 07103095 |
| Issue date: | 11/27/2023 |
| From: | Yoira Diaz-Sanabria Storage and Transportation Licensing Branch |
| To: | Boyle R US Dept of Transportation, Radioactive Materials Branch |
| Shared Package | |
| ML23321A206 | List: |
| References | |
| EPID L-2023-DOT-0009 | |
| Download: ML23321A207 (2) | |
Text
Richard W. Boyle, Chief Radioactive Materials Branch U.S. Department of Transportation 1200 New Jersey Avenue SE Washington, D.C. 20590
SUBJECT:
CERTIFICATE OF APPROVAL NO. D/4377/AF-96 FOR THE MODEL NO. ANF-10 PACKAGE - REVALIDATION RECOMMENDATION
Dear Richard Boyle:
By letter dated May 26, 2023 (Agencywide Documents Access and Management System
[ADAMS] Accession No. ML23297A029), the U.S. Department of Transportation (DOT) requested that the U.S. Nuclear Regulatory Commission (NRC) staff performs a review of the German Certificate of Approval D/4377/AF-96, Revision 1, for the Model No. ANF-10 package and make a recommendation concerning the revalidation of the package for import and export use.
Based upon the NRCs review of the statements and representations contained in the application ANFG-11.105(06E), Revision No. 12, dated January 30, 2019, the letter from Advanced Nuclear Fuels GmbH dated February 18, 2020, and the supporting reference documents, and for the reasons stated in the enclosed safety evaluation report, the NRC recommends revalidation of the German Certificate of Competent Authority D/4377/AF-96, Revision 1, for the ANF-10 package with no additional conditions.
If you have any questions regarding this matter, please contact Pierre Saverot of my staff.
Sincerely, Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No: 71-3095
Enclosure:
Safety Evaluation Report November 27, 2023 Signed by Diaz-Sanabria, Yoira on 11/27/23
ML23321A206 (pkg), ML23321A207 (ltr), ML23323A001(SER)
OFFICE NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NMSS/DFM NAME PSaverot WWheatley JHuang JSmith SSamaddar for TBoyce DATE 11/20/2023 11/20/2023 11/21/2023 11/22/2023 11/22/2023 OFFICE NMSS/DFM NMSS/DFM NAME DJohnson YDiaz-Sanabria DATE 11/27/2023 11/27/2023