Copy of Template for Comparing TLD or OSL to Electronic Personnel Dosimeters
ML23312A346
Person / Time
Issue date: 11/08/2023
From: Steven Garry
NRC/NRR/DRA/ARCB
To:
References
Download: ML23312A346 (122)


Text

Replace demonstration data below with your data Sort it in descending order so the maximum TLD/OSL values are on top ED/TLD TLD ED Ratio 538 557 1.035 534 487 New Boundaries 0.912 518 566 Dose 1.093 511 500 Point 2.5 (TLD)

TLD -2.5 +2.5 TLD -25% 25%

0.978 511 501 10 7.9 10 2

18 0.980 500 534 20 11.2 20 9

31 1.068 498 474 30 13.7 30 16 44 0.952 485 497 40 15.8 40 24 56 1.025 481 527 50 17.7 50 32 68 1.096 477 440 60 19.4 60 41 79 0.922 461 499 70 20.9 70 49 91 1.082 455 477 80 22.4 80 58 102 1.048 442 424 90 23.7 90 66 114 0.959 433 420 100 25.0 100 75 125 100 75 125 0.970 432 437 110 26.2 110 84 136 1.012 424 459 120 27.4 120 93 147 1.083 396 418 130 28.5 130 101 159 1.056 395 384 140 29.6 140 110 170 0.972 384 398 150 30.6 150 119 181 1.036 373 379 160 31.6 160 128 192 1.016 366 345 170 32.6 170 137 203 0.943 359 363 180 33.5 180 146 214 1.011 354 391 190 34.5 190 156 224 1.105 352 336 200 35.4 200 165 235 0.955 342 370 210 36.2 210 174 246 1.082 336 361 220 37.1 220 183 257 1.074 331 323 230 37.9 230 192 268 0.976 330 320 240 38.7 240 201 279 0.970 325 350 250 39.5 250 210 290 1.077 319 301 260 40.3 260 220 300 0.944 317 308 270 41.1 270 229 311 0.972 317 328 280 41.8 280 238 322 1.035 316 330 290 42.6 290 247 333 1.044 309 303 300 43.3 300 257 343 0.981 307 296 310 44.0 310 266 354 0.964 306 330 320 44.7 320 275 365 1.078 301 283 330 45.4 330 285 375 0.940 297 298 340 46.1 340 294 386 1.003 297 318 350 46.8 350 303 397 1.071 290 289 360 47.4 360 313 407 0.997 289 290 370 48.1 370 322 418 1.003 288 279 380 48.7 380 331 429 0.969 288 291 390 49.4 390 341 439 1.010 284 265 400 50.0 400 350 450 400 300 500 0.933 281 269 410 50.6 410 359 461 0.957 281 291 420 51.2 420 369 471 1.036 280 284 430 51.8 430 378 482 1.014 279 255 440 52.4 440 388 492 0.914 279 271 450 53.0 450 397 503 0.971 "Green Lines" "Red Lines" Site ED vs TLD/OSL Results INPO

273 246 460 53.6 460 406 514 0.901 273 297 470 54.2 470 416 524 1.088 272 262 480 54.8 480 425 535 0.963 272 288 490 55.3 490 435 545 1.059 271 272 500 55.9 500 444 556 1.004 270 248 510 56.5 510 454 566 0.919 267 242 520 57.0 520 463 577 0.906 265 257 530 57.6 530 472 588 0.970 264 261 540 58.1 540 482 598 0.989 261 260 550 58.6 550 491 609 0.996 257 259 560 59.2 560 501 619 1.008 256 259 570 59.7 570 510 630 1.012 250 258 580 60.2 580 520 640 1.032 248 249 590 60.7 590 529 651 1.004 246 281 600 61.2 600 539 661 1.142 244 227 610 61.7 610 548 672 0.930 242 236 620 62.2 620 558 682 0.975 241 232 630 62.7 630 567 693 0.963 239 246 640 63.2 640 577 703 1.029 237 225 650 63.7 650 586 714 0.949 236 202 660 64.2 660 596 724 0.856 235 235 670 64.7 670 605 735 1.000 235 243 680 65.2 680 615 745 1.034 234 213 690 65.7 690 624 756 0.910 234 218 700 66.1 700 634 766 0.932 234 220 710 66.6 710 643 777 0.940 234 229 720 67.1 720 653 787 0.979 234 241 730 67.5 730 662 798 1.030 223 204 740 68.0 740 672 808 0.915 223 228 750 68.5 750 682 818 1.022 217 219 760 68.9 760 691 829 1.009 216 206 770 69.4 770 701 839 0.954 220 210 780 69.8 780 710 850 0.955 214 216 790 70.3 790 720 860 1.009 213 209 800 70.7 800 729 871 0.981 212 201 810 71.2 810 739 881 0.948 211 243 820 71.6 820 748 892 1.152 207 195 830 72.0 830 758 902 0.942 206 198 840 72.5 840 768 912 0.961 204 189 850 72.9 850 777 923 0.926 204 216 860 73.3 860 787 933 1.059 203 197 870 73.7 870 796 944 0.970 203 211 880 74.2 880 806 954 1.039 202 209 890 74.6 890 815 965 1.035 200 197 900 75.0 900 825 975 0.985 199 187 910 75.4 910 835 985 0.940 198 218 920 75.8 920 844 996 1.101 197 197 930 76.2 930 854 1006 1.000 196 198 940 76.6 940 863 1017 1.010 195 198 950 77.1 950 873 1027 1.015 193 185 960 77.5 960 883 1037 0.959 185 186 970 77.9 970 892 1048 1.005 184 175 980 78.3 980 902 1058 0.951 181 163 990 78.7 990 911 1069 0.901 178 170 1000 79.1 1000 921 1079 0.955

178 189 1250 88.4 1250 1162 1338 1.062 178 192 1500 96.8 1500 1403 1597 1.079 177 193 1750 104.6 1750 1645 1855 1.090 176 196 2000 111.8 2000 1888 2112 1.114 175 171 0.977 170 153 0.900 170 169 0.994 168 153 0.911 162 155 0.957 162 163 1.006 162 186 1.148 161 164 1.019 160 166 1.038 157 158 1.006 156 133 0.853 156 145 0.929 155 158 1.019 148 149 1.007 148 159 1.074 146 147 1.007 145 149 1.028 141 124 0.879 141 127 0.901 141 136 0.965 136 133 0.978 135 130 0.963 135 142 1.052 135 145 1.074 134 128 0.955 134 129 0.963 134 130 0.970 130 125 0.962 128 132 1.031 126 111 0.881 126 132 1.048 125 104 0.832 125 128 1.024 124 107 0.863 124 119 0.960 123 120 0.976 123 121 0.984 122 133 1.090 121 107 0.884 121 120 0.992 121 122 1.008 121 122 1.008 121 124 1.025 120 114 0.950 120 120 1.000 119 110 0.924 119 121 1.017 119 129 1.084 118 114 0.966 118 121 1.025 117 109 0.932

117 110 0.940 117 117 1.000 117 119 1.017 117 125 1.068 116 108 0.931 115 105 0.913 115 112 0.974 115 116 1.009 115 121 1.052 114 124 1.088 112 104 0.929 112 117 1.045 111 96 0.865 111 98 0.883 111 121 1.090 110 107 0.973 109 114 1.046 107 102 0.953 107 107 1.000 107 108 1.009 106 109 1.028 104 88 0.846 104 93 0.894 103 108 1.049 102 97 0.951 102 99 0.971 116 100 0.862 102 110 1.078 100 95 0.950 100 96 0.960 100 99 0.990 99 84 0.848 98 96 0.980 97 89 0.918 97 95 0.979 96 79 0.823 94 86 0.915 94 100 1.064 93 81 0.871 93 83 0.892 93 96 1.032 92 72 0.783 92 86 0.935 101 86 0.851 92 93 1.011 92 107 1.163 91 87 0.956 91 89 0.978 90 92 1.022 90 96 1.067 90 96 1.067 90 97 1.078 89 84 0.944 89 87 0.978 88 84 0.955

88 86 0.977 87 87 1.000 87 88 1.011 86 82 0.953 86 86 1.000 85 73 0.859 84 70 0.833 84 83 0.988 83 93 1.120 81 80 0.988 81 83 1.025 81 85 1.049 80 85 1.063 80 86 1.075 80 89 1.113 79 78 0.987 79 84 1.063 78 76 0.974 78 77 0.987 77 83 1.078 77 84 1.091 76 69 0.908 76 70 0.921 76 74 0.974 76 78 1.026 75 67 0.893 75 73 0.973 75 76 1.013 74 67 0.905 73 70 0.959 73 71 0.973 72 63 0.875 72 66 0.917 72 66 0.917 71 57 0.803 71 63 0.887 71 73 1.028 70 68 0.971 70 70 1.000 69 67 0.971 69 75 1.087 68 53 0.779 68 58 0.853 68 75 1.103 67 59 0.881 67 62 0.925 66 67 1.015 66 75 1.136 65 56 0.862 65 64 0.985 66 69 1.045 65 73 1.123 64 54 0.844 64 58 0.906 64 62 0.969

62 59 0.952 61 55 0.902 61 67 1.098 61 68 1.115 60 55 0.917 60 58 0.967 60 60 1.000 60 61 1.017 60 65 1.083 59 49 0.831 59 54 0.915 59 57 0.966 59 61 1.034 59 64 1.085 58 54 0.931 58 56 0.966 58 58 1.000 58 60 1.034 57 52 0.912 57 61 1.070 57 68 1.193 56 44 0.786 56 53 0.946 56 53 0.946 56 53 0.946 56 61 1.089 55 52 0.945 55 59 1.073 55 61 1.109 54 44 0.815 54 53 0.981 54 53 0.981 54 59 1.093 53 40 0.755 53 52 0.981 53 53 1.000 53 54 1.019 52 40 0.769 52 41 0.788 52 50 0.962 52 52 1.000 51 59 1.157 50 45 0.900 50 47 0.940 50 48 0.960 50 52 1.040 49 45 0.918 49 48 0.980 49 52 1.061 48 38 0.792 48 48 1.000 48 50 1.042 48 55 1.146 47 37 0.787 47 40 0.851

47 46 0.979 47 47 1.000 47 47 1.000 47 49 1.043 46 38 0.826 46 40 0.870 46 46 1.000 46 49 1.065 45 34 0.756 45 41 0.911 45 41 0.911 45 44 0.978 45 47 1.044 44 43 0.977 45 47 1.044 44 50 1.136 43 41 0.953 43 42 0.977 43 44 1.023 43 47 1.093 42 35 0.833 42 40 0.952 42 40 0.952 42 41 0.976 42 42 1.000 42 43 1.024 42 47 1.119 42 52 1.238 41 39 0.951 41 43 1.049 41 44 1.073 41 49 1.195 0

2

  1. DIV/0!

40 35 0.875 40 35 0.875 40 42 1.050 35 22 0.629 39 33 0.846 39 35 0.897 39 36 0.923 39 37 0.949 39 37 0.949 39 40 1.026 39 47 1.205 38 28 0.737 38 29 0.763 38 34 0.895 38 37 0.974 38 37 0.974 38 39 1.026 38 41 1.079 38 43 1.132 38 43 1.132 37 34 0.919 37 36 0.973

37 37 1.000 37 39 1.054 37 40 1.081 36 31 0.861 36 34 0.944 36 37 1.028 36 38 1.056 36 39 1.083 36 40 1.111 35 30 0.857 35 32 0.914 35 32 0.914 35 32 0.914 35 32 0.914 35 37 1.057 35 37 1.057 35 37 1.057 34 30 0.882 34 33 0.971 34 34 1.000 34 35 1.029 34 36 1.059 34 39 1.147 33 30 0.909 33 30 0.909 33 32 0.970 33 33 1.000 33 34 1.030 33 36 1.091 32 29 0.906 32 30 0.938 32 30 0.938 32 31 0.969 32 31 0.969 32 34 1.063 32 36 1.125 32 36 1.125 32 37 1.156 31 27 0.871 31 29 0.935 31 30 0.968 31 31 1.000 30 32 1.067 30 33 1.100 29 18 0.621 29 25 0.862 29 26 0.897 29 30 1.034 29 30 1.034 29 31 1.069 29 32 1.103 29 33 1.138 29 35 1.207 28 21 0.750 28 23 0.821

28 24 0.857 28 25 0.893 28 26 0.929 28 30 1.071 28 30 1.071 28 31 1.107 28 32 1.143 28 33 1.179 28 33 1.179 28 33 1.179 27 20 0.741 27 24 0.889 27 24 0.889 27 25 0.926 27 27 1.000 27 27 1.000 27 27 1.000 27 30 1.111 27 31 1.148 27 33 1.222 26 22 0.846 26 24 0.923 26 28 1.077 26 30 1.154 26 31 1.192 25 18 0.720 25 19 0.760 25 20 0.800 25 21 0.840 25 21 0.840 25 22 0.880 25 24 0.960 25 24 0.960 25 24 0.960 27 31 1.148 24 16 0.667 24 22 0.917 24 22 0.917 24 25 1.042 24 27 1.125 24 30 1.250 23 17 0.739 23 21 0.913 23 22 0.957 23 22 0.957 23 23 1.000 23 25 1.087 23 30 1.304 23 31 1.348 22 17 0.773 22 19 0.864 22 19 0.864 22 20 0.909 22 21 0.955 22 21 0.955

22 23 1.045 22 24 1.091 22 24 1.091 22 24 1.091 21 15 0.714 21 16 0.762 21 20 0.952 21 20 0.952 21 21 1.000 21 24 1.143 21 24 1.143 21 25 1.190 21 26 1.238 20 16 0.800 20 17 0.850 20 17 0.850 20 18 0.900 20 19 0.950 20 19 0.950 20 20 1.000 20 20 1.000 20 21 1.050 20 23 1.150 19 8

0.421 19 11 0.579 19 16 0.842 19 17 0.895 19 19 1.000 19 19 1.000 19 19 1.000 19 21 1.105 19 21 1.105 19 22 1.158 19 24 1.263 19 25 1.316 19 27 1.421 18 12 0.667 18 12 0.667 18 13 0.722 18 16 0.889 18 16 0.889 18 17 0.944 18 18 1.000 18 18 1.000 18 18 1.000 18 20 1.111 18 21 1.167 18 21 1.167 18 21 1.167 18 23 1.278 18 23 1.278 17 10 0.588 17 12 0.706 17 12 0.706 17 13 0.765

17 13 0.765 17 14 0.824 17 14 0.824 17 16 0.941 17 17 1.000 17 17 1.000 17 18 1.059 17 19 1.118 17 19 1.118 17 20 1.176 17 20 1.176 17 20 1.176 17 21 1.235 17 24 1.412 17 26 1.529 0

2

  1. DIV/0!

16 11 0.688 16 12 0.750 16 12 0.750 16 13 0.813 16 13 0.813 16 13 0.813 16 16 1.000 16 16 1.000 16 18 1.125 16 18 1.125 16 19 1.188 16 19 1.188 16 20 1.250 16 20 1.250 0

  1. DIV/0!

15 10 0.667 15 13 0.867 15 13 0.867 15 13 0.867 15 13 0.867 15 14 0.933 15 15 1.000 15 15 1.000 15 15 1.000 15 16 1.067 15 16 1.067 15 16 1.067 15 16 1.067 15 16 1.067 15 17 1.133 15 18 1.200 15 18 1.200 15 19 1.267 15 19 1.267 15 19 1.267 14 11 0.786 14 11 0.786 14 14 1.000 14 14 1.000

14 14 1.000 14 15 1.071 14 15 1.071 14 16 1.143 14 16 1.143 14 16 1.143 14 19 1.357 13 6

0.462 13 7

0.538 13 8

0.615 7

9 1.286 13 10 0.769 13 13 1.000 13 14 1.077 13 14 1.077 13 15 1.154 13 16 1.231 13 17 1.308 13 17 1.308 13 0.000 0

  1. DIV/0!

12 4

0.333 5

4 0.800 12 6

0.500 12 6

0.500 12 9

0.750 12 9

0.750 12 10 0.833 12 12 1.000 12 12 1.000 12 13 1.083 12 14 1.167 12 14 1.167 12 14 1.167 12 15 1.250 12 17 1.417 12 17 1.417 11 5

0.455 11 7

0.636 11 9

0.818 11 10 0.909 11 10 0.909 11 10 0.909 11 10 0.909 11 10 0.909 11 10 0.909 11 11 1.000 11 11 1.000 11 11 1.000 11 12 1.091 11 13 1.182 11 13 1.182 11 14 1.273 11 14 1.273 11 19 1.727

5 0.000 10 4

0.400 10 5

0.500 10 7

0.700 10 7

0.700 10 7

0.700 10 7

0.700 10 8

0.800 10 8

0.800 10 9

0.900 10 9

0.900 10 10 1.000 10 10 1.000 10 10 1.000 10 10 1.000 10 10 1.000 10 11 1.100 10 11 1.100 10 12 1.200 10 12 1.200 10 13 1.300 12 13 1.083 10 14 1.400 10 14 1.400 10 14 1.400 10 15 1.500 20 20 1.000 9

1 0.111 9

3 0.333 9

3 0.333 9

4 0.444 9

5 0.556 9

6 0.667 9

6 0.667 9

6 0.667 9

6 0.667 9

7 0.778 9

7 0.778 9

8 0.889 9

8 0.889 9

8 0.889 9

8 0.889 9

9 1.000 9

10 1.111 9

10 1.111 9

11 1.222 9

11 1.222 9

11 1.222 10 11 1.100 9

12 1.333 9

12 1.333 9

13 1.444 9

14 1.556 0

  1. DIV/0!

8 2

0.250

8 4

0.500 8

4 0.500 0

5

  1. DIV/0!

9 5

0.556 8

5 0.625 8

6 0.750 8

6 0.750 8

7 0.875 8

7 0.875 8

7 0.875 8

7 0.875 8

8 1.000 8

8 1.000 8

8 1.000 8

8 1.000 8

9 1.125 8

9 1.125 8

9 1.125 8

9 1.125 8

10 1.250 8

10 1.250 9

10 1.111 8

11 1.375 8

11 1.375 8

11 1.375 8

12 1.500 8

13 1.625 0

  1. DIV/0!

7 4

0.571 7

4 0.571 7

4 0.571 7

5 0.714 7

5 0.714 7

6 0.857 7

6 0.857 7

6 0.857 7

7 1.000 7

7 1.000 7

7 1.000 7

7 1.000 7

7 1.000 7

8 1.143 7

8 1.143 8

8 1.000 7

8 1.143 7

8 1.143 7

8 1.143 7

8 1.143 7

9 1.286 7

10 1.429 7

10 1.429 7

12 1.714 7

13 1.857 7

13 1.857 6

1 0.167

6 2

0.333 6

3 0.500 6

3 0.500 6

4 0.667 6

4 0.667 6

4 0.667 6

4 0.667 6

4 0.667 6

5 0.833 6

5 0.833 6

5 0.833 6

5 0.833 6

5 0.833 6

5 0.833 6

6 1.000 6

7 1.167 6

7 1.167 6

7 1.167 6

8 1.333 6

8 1.333 6

8 1.333 6

9 1.500 6

9 1.500 6

9 1.500 6

9 1.500 6

9 1.500 6

10 1.667 6

10 1.667 6

10 1.667 6

10 1.667 6

10 1.667 6

11 1.833 0

  1. DIV/0!

6 0.000 0

  1. DIV/0!

6 0.000 0

  1. DIV/0!

5 1

0.200 5

1 0.200 5

2 0.400 5

3 0.600 5

4 0.800 5

5 1.000 5

6 1.200 5

8 1.600 5

8 1.600 5

9 1.800 5

10 2.000 0

  1. DIV/0!

0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 0

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 1

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 2

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 3

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 4

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

0 5

  1. DIV/0!

5 5

1.000 5

5 1.000 5

5 1.000 5

5 1.000 5

5 1.000 5

5 1.000 0

6

  1. DIV/0!

5 6

1.200 0

6

  1. DIV/0!

5 6

1.200 0

6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

0 6

  1. DIV/0!

5 6

1.200 5

6 1.200 5

6 1.200 5

7 1.400 0

7

  1. DIV/0!

0 7

  1. DIV/0!

0 7

  1. DIV/0!

0 7

  1. DIV/0!

0 7

  1. DIV/0!

5 7

1.400 0

7

  1. DIV/0!

0 7

  1. DIV/0!

0 7

  1. DIV/0!

5 7

1.400 5

7 1.400 5

7 1.400 5

7 1.400 5

7 1.400 5

7 1.400 5

7 1.400 5

8 1.600 5

8 1.600 5

8 1.600 5

8 1.600 5

8 1.600 5

8 1.600

0 8

  1. DIV/0!

5 8

1.600 5

8 1.600 5

9 1.800 9

9 1.000 5

9 1.800 5

9 1.800 5

10 2.000 0

  1. DIV/0!

0

  1. DIV/0!

0

  1. DIV/0!

0

  1. DIV/0!

21 28 1.333 21 27 1.286 21 26 1.238 21 25 1.190 21 22 1.048 21 22 1.048 21 18 0.857 21 16 0.762 21 16 0.762 21 15 0.714 21 13 0.619 20 26 1.303 20 23 1.153 20 22 1.103 20 20 1.003 20 20 1.003 20 20 1.003 20 20 1.003 20 19 0.952 20 19 0.952 20 19 0.952 20 19 0.952 20 17 0.852 20 17 0.852 20 15 0.752 20 13 0.652 20 13 0.652 20 13 0.652 20 12 0.602 20 12 0.602 20 11 0.551 20 8

0.401 19 24 1.270 19 23 1.217 19 21 1.111 19 21 1.111 19 20 1.058 19 20 1.058 19 20 1.058 19 19 1.005 19 19 1.005 19 19 1.005 19 18 0.952

19 17 0.899 19 17 0.899 19 16 0.847 19 16 0.847 19 16 0.847 19 15 0.794 19 14 0.741 19 13 0.688 19 13 0.688 19 11 0.582 19 10 0.529 19 10 0.529 19 10 0.529 19 9

0.476 19 5

0.265 18 26 1.457 18 24 1.345 18 23 1.289 18 21 1.176 18 20 1.120 18 19 1.064 18 19 1.064 18 19 1.064 18 18 1.008 18 18 1.008 18 18 1.008 18 17 0.952 18 16 0.896 18 16 0.896 18 15 0.840 18 15 0.840 18 14 0.784 18 14 0.784 18 14 0.784 18 13 0.728 18 13 0.728 18 12 0.672 18 12 0.672 18 7

0.392 17 26 1.548 17 24 1.429 17 22 1.310 17 22 1.310 17 20 1.190 17 19 1.131 17 19 1.131 17 18 1.071 17 18 1.071 17 17 1.012 17 17 1.012 17 17 1.012 17 17 1.012 17 16 0.952 17 15 0.893 17 15 0.893

17 15 0.893 17 14 0.833 17 11 0.655 17 11 0.655 17 6

0.357 17 4

0.238 16 29 1.841 16 22 1.397 16 20 1.270 16 20 1.270 16 19 1.206 16 18 1.143 16 17 1.079 16 17 1.079 16 16 1.016 16 14 0.889 16 14 0.889 16 14 0.889 16 14 0.889 16 13 0.825 16 13 0.825 16 12 0.762 16 10 0.635 16 5

0.317 16 5

0.317 15 20 1.361 15 19 1.293 15 19 1.293 15 18 1.224 15 16 1.088 15 16 1.088 15 15 1.020 15 15 1.020 15 15 1.020 15 15 1.020 15 15 1.020 15 14 0.952 15 14 0.952 15 14 0.952 15 14 0.952 15 13 0.884 15 11 0.748 15 11 0.748 15 8

0.544 15 7

0.476 15 7

0.476 15 7

0.476 15 7

0.476 15 3

0.204 14 18 1.319 14 18 1.319 14 17 1.245 14 17 1.245 14 15 1.099 14 14 1.026

14 14 1.026 14 13 0.952 14 13 0.952 14 13 0.952 14 13 0.952 14 13 0.952 14 13 0.952 14 13 0.952 14 13 0.952 14 12 0.879 14 12 0.879 14 12 0.879 14 11 0.806 14 10 0.733 14 10 0.733 14 10 0.733 14 10 0.733 14 10 0.733 14 9

0.659 14 8

0.586 14 7

0.513 14 5

0.366 14 4

0.293 13 17 1.349 13 17 1.349 13 17 1.349 13 16 1.270 13 16 1.270 13 16 1.270 13 16 1.270 13 16 1.270 13 16 1.270 13 15 1.190 13 15 1.190 13 15 1.190 13 14 1.111 13 14 1.111 13 14 1.111 13 13 1.032 13 13 1.032 13 12 0.952 13 12 0.952 13 12 0.952 13 12 0.952 13 11 0.873 13 11 0.873 13 10 0.794 13 10 0.794 13 9

0.714 13 9

0.714 13 8

0.635 13 8

0.635 13 7

0.556 13 6

0.476 13 5

0.397

13 1

0.079 13 0

0.000 12 17 1.472 12 17 1.472 12 17 1.472 12 15 1.299 12 14 1.212 12 14 1.212 12 14 1.212 12 13 1.126 12 13 1.126 12 13 1.126 12 12 1.039 12 12 1.039 12 12 1.039 12 11 0.952 12 11 0.952 12 11 0.952 12 10 0.866 12 10 0.866 12 10 0.866 12 9

0.779 12 9

0.779 12 8

0.693 12 7

0.606 12 6

0.519 12 3

0.260 12 2

0.173 12 0

0.000 11 19 1.810 11 13 1.238 11 12 1.143 11 11 1.048 11 11 1.048 11 10 0.952 11 10 0.952 11 10 0.952 11 10 0.952 11 10 0.952 11 10 0.952 11 8

0.762 11 8

0.762 11 8

0.762 11 7

0.667 11 7

0.667 11 7

0.667 11 7

0.667 11 7

0.667 11 6

0.571 11 6

0.571 11 6

0.571 11 6

0.571 11 6

0.571 11 5

0.476 11 5

0.476

11 4

0.381 11 3

0.286 11 1

0.095 11 0

0.000 9

16 1.693 9

13 1.376 9

13 1.376 9

13 1.376 9

13 1.376 9

12 1.270 9

12 1.270 9

11 1.164 9

11 1.164 9

10 1.058 9

10 1.058 9

10 1.058 9

9 0.952 9

9 0.952 9

9 0.952 9

9 0.952 9

8 0.847 9

8 0.847 9

7 0.741 9

7 0.741 9

6 0.635 9

4 0.423 9

4 0.423 9

4 0.423 9

4 0.423 9

4 0.423 9

4 0.423 9

3 0.317 9

2 0.212 9

2 0.212 9

2 0.212 8

14 1.667 8

14 1.667 8

14 1.667 8

11 1.310 8

11 1.310 8

11 1.310 8

11 1.310 8

10 1.190 8

10 1.190 8

10 1.190 8

10 1.190 8

10 1.190 8

10 1.190 8

10 1.190 8

9 1.071 8

9 1.071 8

9 1.071 8

9 1.071 8

9 1.071 8

9 1.071

8 8

0.952 8

8 0.952 8

8 0.952 8

8 0.952 8

7 0.833 8

7 0.833 8

7 0.833 8

7 0.833 8

6 0.714 8

6 0.714 8

6 0.714 8

5 0.595 8

5 0.595 8

4 0.476 8

4 0.476 8

3 0.357 8

3 0.357 8

2 0.238 8

2 0.238 8

1 0.119 8

1 0.119 8

0 0.000 8

0 0.000 7

16 2.177 7

14 1.905 7

13 1.769 7

13 1.769 7

13 1.769 7

12 1.633 7

12 1.633 7

11 1.497 7

11 1.497 7

10 1.361 7

10 1.361 7

10 1.361 7

10 1.361 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

9 1.224 7

8 1.088 7

8 1.088 7

8 1.088 7

8 1.088 7

7 0.952 7

7 0.952 7

7 0.952 7

7 0.952 7

7 0.952 7

6 0.816

7 6

0.816 7

6 0.816 7

5 0.680 7

4 0.544 7

4 0.544 7

2 0.272 7

2 0.272 7

2 0.272 7

2 0.272 7

2 0.272 7

1 0.136 7

1 0.136 7

1 0.136 7

1 0.136 7

0 0.000 6

10 1.587 6

10 1.587 6

9 1.429 6

9 1.429 6

9 1.429 6

9 1.429 6

8 1.270 6

8 1.270 6

8 1.270 6

8 1.270 6

8 1.270 6

8 1.270 6

7 1.111 6

7 1.111 6

7 1.111 6

7 1.111 6

7 1.111 6

7 1.111 6

6 0.952 6

6 0.952 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

5 0.794 6

4 0.635 6

4 0.635 6

4 0.635 6

4 0.635 6

4 0.635 6

3 0.476 6

3 0.476 6

3 0.476 6

3 0.476 6

2 0.317 6

2 0.317

6 1

0.159 6

1 0.159 6

1 0.159 6

1 0.159 6

1 0.159 6

1 0.159 6

1 0.159 6

0 0.000 6

0 0.000 6

0 0.000 6

0 0.000 5

15 2.857 5

13 2.476 5

12 2.286 5

11 2.095 5

11 2.095 5

10 1.905 5

10 1.905 5

9 1.714 5

9 1.714 5

9 1.714 5

9 1.714 5

9 1.714 5

8 1.524 5

8 1.524 5

8 1.524 5

8 1.524 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

7 1.333 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

6 1.143 5

5 0.952 5

5 0.952

5 5

0.952 5

5 0.952 5

5 0.952 5

5 0.952 5

5 0.952 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

4 0.762 5

3 0.571 5

3 0.571 5

2 0.381 5

2 0.381 5

2 0.381 5

1 0.190 5

1 0.190 5

1 0.190 5

1 0.190 5

0 0.000 5

0 0.000 3

3 0.952 3

3 0.952 0

9 0

9 0

8 0

8 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

7 0

6 0

6 0

6 0

6 0

6 0

6 0

6 0

6 0

6 0

6

0 6

0 6

0 6

0 6

0 6

0 6

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 5

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 4

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 3

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 2

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

0 1

Lower Red Line (Columns W & X)[Series 1]

Upper Red Line Columns (W & Y)[Series 2]

Lower Green Line (ColumnsT & U)[Series 3]

Upper Green Line (Columns T & V)[Series 4]

Data Points (Columns M & N)[Series 5]

10 1.791 0.209 620 "Bell Curve" [Columns M & Z] (2nd Chart) 20 1.559 0.441 614 30 1.456 0.544 584 40 1.395 0.605 578 50 1.354 0.646 568 60 1.323 0.677 561 70 1.299 0.701 553 80 1.280 0.720 544 90 1.264 0.736 544 100 1.250 0.750 543 110 1.238 0.762 540 120 1.228 0.772 540 130 1.219 0.781 537 140 1.211 0.789 527 150 1.204 0.796 502 160 1.198 0.802 502 170 1.192 0.808 502 180 1.186 0.814 498 190 1.181 0.819 496 200 1.177 0.823 492 210 1.173 0.827 485 220 1.169 0.831 484 230 1.165 0.835 482 240 1.161 0.839 481 250 1.158 0.842 481 260 1.155 0.845 473 270 1.152 0.848 470 280 1.149 0.851 466 290 1.147 0.853 466 300 1.144 0.856 463 310 1.142 0.858 460 320 1.140 0.860 454 330 1.138 0.862 445 340 1.136 0.864 443 350 1.134 0.866 437 360 1.132 0.868 429 370 1.130 0.870 423 380 1.128 0.872 421 390 1.127 0.873 410 400 1.125 0.875 406 410 1.123 0.877 402 420 1.122 0.878 396 430 1.121 0.879 393 440 1.119 0.881 386 450 1.118 0.882 382 460 1.117 0.883 380 470 1.115 0.885 376 480 1.114 0.886 366 490 1.113 0.887 365

500 1.112 0.888 358 357 353 345 339 338 333 333 332 331 328 327 326 322 318 317 316 315 314 314 313 312 308 303 302 301 300 299 299 299 299 298 297 285 284 282 282 281 280 279 275 274 272 271 270 268 267 267 264 259 258 257 257 256 251

245 245 244 240 240 239 239 238 237 235 233 232 231 231 230 230 229 229 227 227 226 225 225 224 222 222 219 217 216 215 211 209 209 209 208 207 207 206 206 204 204 203 203 203 202 201 197 197 196 196 195 195 194 193 193

191 190 190 189 186 185 184 183 182 182 181 181 180 177 176 175 175 175 174 174 173 173 173 172 172 171 171 170 170 170 169 169 169 169 167 166 166 166 166 166 165 164 164 163 162 161 160 158 156 156 156 156 156 154 153

152 152 151 151 151 150 150 149 148 148 148 147 147 147 147 146 146 146 146 145 145 145 145 144 144 144 144 144 143 142 142 141 141 141 140 140 139 139 139 139 139 139 138 138 137 137 137 135 135 135 135 135 134 134 134

134 134 134 134 133 133 133 133 132 132 132 132 132 132 132 132 132 131 131 131 130 130 130 130 129 129 128 128 128 127 127 127 127 126 126 126 126 126 125 125 125 125 125 125 124 124 124 123 123 123 122 122 122 122 122

122 122 122 122 121 121 120 120 120 120 119 119 119 119 119 119 118 118 118 118 118 117 117 116 116 116 116 114 114 114 114 114 114 114 114 113 113 113 113 113 112 112 111 111 111 111 111 110 110 110 110 110 110 110 109

108 108 108 108 108 108 108 108 107 107 107 106 106 106 106 105 105 105 105 105 104 104 104 104 104 104 103 103 103 103 103 103 102 102 102 102 102 102 101 101 101 101 101 101 101 101 101 101 100 100 100 100 100 100 100

100 99 99 99 99 99 99 98 98 98 98 97 97 97 97 97 97 97 97 96 96 96 96 96 96 96 96 95 95 95 95 95 95 95 95 95 93 93 93 93 93 93 93 92 92 92 92 91 91 91 91 91 91 90 90

89 89 89 89 88 88 88 87 87 87 87 87 87 86 86 86 85 85 85 85 85 84 84 84 84 84 84 84 84 84 84 84 84 84 84 83 83 83 83 83 83 83 83 83 83 83 83 83 82 82 82 82 82 82 82

82 82 81 81 81 81 81 81 81 81 81 80 80 80 80 80 80 80 80 80 80 80 80 80 79 79 79 79 79 79 79 79 79 79 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 77 77 77 77 76 76

76 76 76 76 75 75 75 75 75 75 75 74 74 74 74 74 74 74 74 74 74 74 74 72 72 72 72 72 72 72 72 72 72 72 71 71 71 71 71 71 71 71 71 71 70 70 70 70 70 70 70 70 70 70 69

69 69 69 69 69 69 68 68 68 68 68 68 68 68 68 68 68 67 67 67 67 67 67 67 67 67 67 67 67 66 66 66 66 66 66 66 66 65 65 65 65 65 65 65 65 65 64 64 64 64 64 64 64 64 64

64 64 64 64 64 64 64 64 64 63 63 63 63 63 63 63 63 63 62 62 62 62 62 62 62 62 62 62 62 61 61 61 61 61 61 61 60 60 60 60 60 60 60 60 60 60 60 59 59 59 59 59 59 59 59

59 59 59 59 59 58 58 58 58 58 58 58 58 58 57 57 57 57 57 57 57 56 56 56 56 56 56 56 55 55 55 55 55 55 55 55 55 55 55 55 55 55 54 54 54 54 54 54 54 54 54 54 54 54 54

54 54 54 54 54 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 51 51 51 51 51 51 51 51 51 51 51 51 50 50 50 50 50 50 50 50 50 50 50 50 50 49 49 49 49 49 49 49 49 48

48 48 48 48 48 48 48 48 48 47 47 47 47 47 47 47 47 47 46 46 46 46 46 46 46 46 45 45 45 45 45 45 45 45 45 45 45 44 44 44 44 44 44 44 44 44 44 44 43 43 43 43 43 43 43

43 43 43 43 43 43 42 42 42 42 42 42 42 42 42 42 42 42 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 40 40 40 40 40 40 40 40 39 39 39 39 39 39 39 39 39 39 39 39

38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 37 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36

35 35 35 35 35 35 35 35 35 35 35 35 34 34 34 34 34 34 34 34 34 34 34 34 34 33 33 33 33 33 33 33 33 33 33 33 33 33 33 33 32 32 32 32 32 32 32 32 32 32 32 32 30 30 30

30 30 30 30 30 30 30 30 30 30 30 29 29 29 29 29 29 29 29 29 29 29 29 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28 27 27 27 27 27 27 27 27 27 27 27 26 26 26 26 26 26

26 26 26 26 26 26 26 26 26 26 25 25 25 25 25 25 25 25 25 25 25 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 23 23 23 23 23 23 23 23 23 23 22 22 22 22 22

22 22 22 22 22 22 22 22 22 22 21 21 21 21 21 21 21 21 21 21 21 21 21 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 19 19 19 19 19 19 19 19 19 19 19

19 19 19 19 19 19 19 19 19 19 19 19 19 19 19 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17

17 17 17 17 17 17 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 15 14 14 14 14 14 14

14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13 13

13 13 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11

11 11 11 11 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

9 9

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 8

8 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7

7 7

7 7

7 7

7 7

7 7

7 7

7 7

7 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6 6

6

6 6

6 6

6 6

6 6

6 6

6 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 3

3 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0

0 0

0

654 655 602 629 562 569 588 583 561 572 570 551 561 552 547 529 493 523 524 534 501 500 501 510 502 505 508 504 501 489 493 490 462 464 448 424 426 435 441 417 383 381 412 393 384 362 358 367 382

364 378 379 329 338 340 366 356 326 354 365 311 310 321 322 319 300 347 322 303 314 310 330 331 317 315 311 311 293 291 283 284 284 273 302 329 270 291 309 287 277 288 259 278 263 286 265 246 293 247 283 260 215 294 233

260 249 231 262 229 255 239 239 261 224 253 221 258 238 238 216 231 222 227 209 194 215 214 213 211 187 208 177 226 205 206 217 203 199 195 221 218 210 205 216 188 224 214 209 186 205 230 194 198 190 201 195 214 202 201

194 203 200 197 187 173 180 195 186 176 177 175 156 191 181 175 174 164 179 171 196 192 185 182 169 173 172 168 164 164 190 176 161 143 182 182 162 160 159 139 171 170 168 146 149 153 152 149 169 154 152 151 149 155 155

159 144 163 157 155 164 159 133 151 142 132 155 147 141 137 150 142 136 132 148 144 143 122 164 148 138 130 122 152 148 132 132 132 125 140 138 152 140 134 128 127 110 127 123 162 139 116 143 141 132 119 115 152 146 128

127 125 125 106 131 127 127 124 148 140 138 137 126 126 125 125 124 135 123 119 135 134 124 115 137 125 136 135 111 138 133 129 126 138 133 133 121 120 134 128 127 125 124 123 122 121 109 120 118 107 141 134 126 123 119

116 112 109 108 118 111 130 125 114 109 130 121 118 115 114 97 117 116 116 116 110 131 105 122 115 110 96 119 118 117 115 114 113 109 96 126 112 109 96 96 112 111 120 111 107 105 102 125 122 107 106 102 92 86 103

115 114 110 106 104 99 99 98 112 102 99 116 106 102 98 119 102 94 90 90 111 110 101 101 93 77 106 104 103 100 92 88 105 103 99 99 87 80 111 108 106 104 103 102 100 97 92 66 102 100 99 99 95 90 88

84 102 101 97 92 90 88 110 98 95 92 110 106 104 99 96 92 78 74 108 103 96 92 92 91 83 82 100 94 93 93 92 92 88 87 80 107 104 97 80 77 77 71 103 89 88 76 100 97 96 95 84 82 87 85

83 80 72 67 95 90 85 92 90 86 86 72 64 92 88 82 91 90 85 83 77 94 92 91 88 85 85 81 79 77 77 76 75 75 72 94 90 90 85 83 81 80 79 78 77 74 74 68 88 87 82 81 78 77 76

74 60 95 91 82 81 79 73 72 66 61 93 86 83 79 78 78 77 76 75 75 73 66 57 95 84 82 77 77 77 76 74 73 65 92 86 85 84 83 82 80 80 78 75 71 69 65 62 57 76 73 67 65 83 82

79 76 75 70 87 81 80 78 69 62 61 87 80 76 75 74 72 70 69 68 63 62 59 80 79 74 73 72 72 71 71 64 63 60 83 74 74 74 72 71 70 69 57 53 79 77 76 76 73 70 69 65 64 54 85

70 69 68 67 60 60 82 79 72 67 67 67 59 58 57 57 56 80 70 64 64 63 62 62 62 61 56 56 50 75 71 64 62 60 58 57 55 79 72 69 66 66 64 58 55 44 71 70 66 65 63 63 63 63 61

60 59 58 56 55 55 55 54 45 70 67 59 56 56 55 54 52 49 68 68 66 60 59 58 56 55 52 51 45 68 65 64 61 56 51 50 68 66 61 61 60 59 57 57 56 51 47 65 64 63 62 61 60 57 56

55 55 55 53 50 60 55 55 53 50 49 49 48 42 56 56 54 51 51 50 48 60 52 50 50 49 46 43 59 58 55 55 53 52 51 49 49 48 47 45 45 43 63 60 60 56 56 55 55 54 54 49 47 46 46

43 43 39 39 31 57 55 55 55 51 51 49 47 45 44 44 43 43 40 40 33 56 56 55 53 52 51 49 49 49 49 45 38 54 51 51 48 47 46 46 46 45 44 44 41 41 55 52 50 46 43 39 35 33 56

54 47 44 44 44 39 39 37 34 52 49 46 46 46 44 41 39 37 52 47 46 45 42 41 37 33 51 50 50 48 43 43 43 41 37 37 37 48 48 47 46 45 43 42 40 35 33 31 47 45 43 42 41 41 40

38 36 33 32 27 24 49 47 47 44 43 41 39 36 36 32 31 28 45 44 44 43 43 41 41 41 35 35 33 33 33 33 31 30 29 45 44 43 37 36 36 35 35 45 45 44 42 41 40 35 33 32 29 27 20

41 41 40 39 39 38 38 38 37 36 35 35 35 33 33 32 31 31 29 47 44 42 41 40 39 38 37 37 35 35 34 34 33 33 33 32 32 30 30 29 39 39 38 37 35 34 33 33 32 31 30 30 25 24 21

38 37 36 36 33 33 32 30 29 28 27 24 42 38 37 36 35 33 33 33 33 32 31 31 29 42 39 37 35 35 33 32 32 32 30 29 28 26 20 10 38 37 31 31 30 29 29 29 25 24 23 23 34 30 30

29 28 28 26 26 26 25 25 24 23 11 36 33 32 32 31 29 28 28 28 23 21 21 35 34 34 31 29 26 26 26 25 24 24 23 22 22 16 34 33 31 29 28 27 27 26 24 23 23 35 29 28 28 28 27

27 27 26 25 25 22 20 20 20 8

33 31 28 25 24 23 23 22 21 21 0

35 30 28 27 27 25 24 23 23 22 22 22 21 21 20 17 16 13 13 32 27 26 25 24 20 18 14 11 11 31 28 26 24 23

22 22 21 20 19 19 17 16 14 7

30 28 28 27 26 25 22 22 18 16 16 15 13 26 23 22 20 20 20 20 19 19 19 19 17 17 15 13 13 13 12 12 11 8

24 23 21 21 20 20 20 19 19 19 18

17 17 16 16 16 15 14 13 13 11 10 10 10 9

5 26 24 23 21 20 19 19 19 18 18 18 17 16 16 15 15 14 14 14 13 13 12 12 7

26 24 22 22 20 19 19 18 18 17 17 17 17 16 15 15

15 14 11 11 6

4 29 22 20 20 19 18 17 17 16 14 14 14 14 13 13 12 10 5

5 20 19 19 18 16 16 15 15 15 15 15 14 14 14 14 13 11 11 8

7 7

7 7

3 18 18 17 17 15 14

14 13 13 13 13 13 13 13 13 12 12 12 11 10 10 10 10 10 9

8 7

5 4

17 17 17 16 16 16 16 16 16 15 15 15 14 14 14 13 13 12 12 12 12 11 11 10 10 9

9 8

8 7

6 5

1 0

17 17 17 15 14 14 14 13 13 13 12 12 12 11 11 11 10 10 10 9

9 8

7 6

3 2

0 19 13 12 11 11 10 10 10 10 10 10 8

8 8

7 7

7 7

7 6

6 6

6 6

5 5

4 3

1 0

16 13 13 13 13 12 12 11 11 10 10 10 9

9 9

9 8

8 7

7 6

4 4

4 4

4 4

3 2

2 2

14 14 14 11 11 11 11 10 10 10 10 10 10 10 9

9 9

9 9

9

8 8

8 8

7 7

7 7

6 6

6 5

5 4

4 3

3 2

2 1

1 0

0 16 14 13 13 13 12 12 11 11 10 10 10 10 9

9 9

9 9

9 9

9 9

8 8

8 8

7 7

7 7

7 6

6 6

5 4

4 2

2 2

2 2

1 1

1 1

0 10 10 9

9 9

9 8

8 8

8 8

8 7

7 7

7 7

7 6

6 5

5 5

5 5

5 5

5 5

4 4

4 4

4 3

3 3

3 2

2

1 1

1 1

1 1

1 0

0 0

0 15 13 12 11 11 10 10 9

9 9

9 9

8 8

8 8

7 7

7 7

7 7

7 7

7 7

7 7

7 6

6 6

6 6

6 6

6 6

6 6

6 6

5 5

5 5

5 5

5 4

4 4

4 4

4 4

4 4

3 3

2 2

2 1

1 1

1 0

0 3

3 9

9 8

8 7

7 7

7 7

7 7

7 7

7 7

7 7

7 6

6 6

6 6

6 6

6 6

6

6 6

6 6

6 6

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 5

5 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4 4

4

4 4

4 4

4 4

4 4

4 4

4 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3

3 3

3 3

3 3

3 3

3 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

2 2

1 1

1 1

1 1

1 1

1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1 1

1

1 1

100

235-00883-MWL January 29, 2004 Attachment The picture can't be displayed.

0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 0

50 100 150 200 250 300 350 400 450 500 550 600 650 700 ED (mrem)

TLD Results (mrem)

Red Boundary = INPO Guidance: +/- 25% if TLD or EPD >100 mrem Green Boundary = 99% Confidence Limit for TLD >10 mrem

= 2.5 where = Sqrt (TLD) for TLD < or = 10 mrem, EPD >= 18 mrem 1st Half 20XX ED vs. TLD/OSL

0.500 0.550 0.600 0.650 0.700 0.750 0.800 0.850 0.900 0.950 1.000 1.050 1.100 1.150 1.200 1.250 1.300 1.350 1.400 1.450 1.500 0

100 200 300 400 500 600 Ratio EL/TLD or OSL TLD/OSL Results