ENCLOSURE 1 M230133 Open Session Presentation Slides for New Powder Container Meeting Non-Proprietary Information
Discussion with the NRC:
NPC Package Revised Technical Basis to Support 8 wt.% U-235 Presentation confidentiality disclosure.
1 October 24, 2023 Non-Proprietary Information
GEH PROPRIETARY INFORMATION NON-PUBLIC
- Overview of the New Powder Container (NPC) package
- Overview of NPC package analysis assumptions
- Review the results of the certification testing
- Overview of proposed changes to the NPC package criticality analysis assumptions
- Review of initial scoping results 2
Agenda Non-Proprietary Information
GEH PROPRIETARY INFORMATION NON-PUBLIC Purpose A. Provide technical basis for the proposed changes to the criticality analysis of the NPC package:
1.
Increase fissile material enrichment limitation to 8 wt.% U-235 2.
Adjust USL and benchmarking 3.
Credit certification test results for limited moderator intrusion B. Items not changing from approved USA/9294/AF-96 (CoC) 1.
Maintain content limitation of 540 kg net per NPC package and Criticality Safety Index (CSI) of 0.7 2.
No package or hardware modifications 3.
Uranium compositions unchanged 3
Non-Proprietary Information
Overview of NPC Package Presentation confidentiality disclosure.
4 Non-Proprietary Information
General Information - NEDO-33881 Revision 7
- NRC approved for Type A fissile material up to 5 wt.% U-235
- Ceramic fiber and polyurethane insulation
- Nine SS Inner Containment Canister Assemblies (ICCAs)
- ICCAs sealed with rubber gasketed SS lid
- Each ICCA wrapped with 20-mil cadmium sheet and 15-mil high density polyethylene 5
Non-Proprietary Information
GEH PROPRIETARY INFORMATION NON-PUBLIC END OF OPEN SESSION Non-Proprietary Information