Enclosure 2: SMR, LLC Meeting Presentation Materials for September 20, 2023
ML23254A367
Person / Time
Site: 99902049
Issue date: 09/20/2023
From: Protesto M
Holtec, SMR
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23254A364 List:
References
160-USNRC-061
Download: ML23254A367 (1)


Text

www.holtec.com www.smrllc.com Concept of Operations and Simulator Development September 20, 2023 Presented by: Michael Protesto SMR, LLC, A Holtec International Company Krishna P. Singh Technology Campus One Holtec Boulevard Camden, NJ 08104, USA

[Not Export Controlled]

holtec.com l smrllc.com l Page 2 Meeting Agenda

Introductions

Purpose & Outcome Overview of Concept of Operations Discussion on Multi-Unit Simulation Requirements Open Forum

holtec.com l smrllc.com l Page 3 Purpose and Outcome PURPOSE To provide a high-level overview of the concept of operation and intended implementation plan with regards to Human Factors Engineering efforts and development of a Plant-referenced simulator.

OUTCOME To obtain feedback from the NRC staff on the execution plan for the simulator development with regards to 1.

Human Factors Engineering Verification and Validation IAW NUREG-0711 2.

Declaration of a Plant-Referenced Simulator for licensing examination IAW 10 CFR 55

holtec.com l smrllc.com l Page 4 Concept of Operations - Plant Design Passive safety systems relying on one time DC-powered valve actuation No credited operator actions during DBAs Minimum number of important human actions (IHAs) expected

No PSA-determined IHAs at this time Advanced digital system for automated controls reducing licensed operator workload

holtec.com l smrllc.com l Page 5 Concept of Operations - HSI Design The HSI is designed to reduce the operators workload and minimize the potential for human errors.

The HSI will detect and provide a means for recovery due to human error.

The HSI provides all the support functions (indications, alarms, controls) the operator requires to monitor and control the plant.

Automatic indications will be displayed for bypassed or inoperable safety systems/functions.

The HSI contains computer-based procedures and displays the appropriate systems status and controls for the in-use procedure(s).

The HSI provides the operator an opportunity to override an automatic function if the operator determines the need to do so.

holtec.com l smrllc.com l Page 6 Concept of Operations - Licensed Operators

((

))

The HSIs for each unit are represented on multiple Video Display Units (VDUs) at the RO and the SRO workstations.

The plant is designed to be highly automated. The main role of the operator is to monitor the plant status and evolutions to ensure that the HSI is controlling properly and that the plant is responding correctly.

holtec.com l smrllc.com l Page 7 Concept of Operations - Operator Training The licensed operators are trained to Provide backup monitoring of the automated functions or to override the automatic response and provide manual response if necessary.

Operate the safety and support systems of the plant.

Training will cover not only plant systems design and functions, but also how the HSI functions, potential failure modes of the HSI, and backup methods for monitoring and controlling the plant in the unlikely event of an HSI failure.

holtec.com l smrllc.com l Page 8 Human Factors Engineering The HFE process plays a critical role in determining control room operation through the following elements:

Operating Experience Review (OER) - identifies staffing related lessons learned Functional Requirements Analysis/ Function Allocation (FRA/FA) - establishes actions necessary to support required functions and allocates to operator performed or automatic Task Analysis (TA) - analyzes the comprehensive requirements and support needed to satisfy the task function Staffing and Qualifications (S&Q) - evaluates operational workload to determine appropriate staffing levels and qualifications needed Procedure Development (PD) - develops guidance for performing operator actions Verification and Validation (V&V) - validates system and plant responses using the task analysis and procedure guidance with the expected staffing

holtec.com l smrllc.com l Page 9 Simulator Development From NUREG/CR-6838, Staffing Plan Validation methods include:

Table Top Analysis Operating Experience Data Simulator Studies Human Performance Models The human performance measure used for validation will be identified and defined regardless of the method used.

holtec.com l smrllc.com l Page 10 Simulator Development The evaluation process will center on the below criteria based on the effects of the new concept of operation design:

Operator and team performance Situation awareness Cognitive workload NUREG/CR-7126 Until such research in complete, HFE reviewers should request applicants to justify their proposed multi-unit operational strategy, e.g., by simulations.

holtec.com l smrllc.com l Page 11 Simulator Development The use of a mix of validation methods will verify a comprehensive assessment of the proposed staffing plan.

Provides the opportunity for convergence of the results from multiple approaches to increase the confidence level of the analysis.

Alternate means allows for continued HFE refinement as the simulator is developed.

holtec.com l smrllc.com l Page 12 Simulator Development Recent multi-unit validations:

The SPV included simultaneous abnormal and emergency events on multiple modules to produce challenging and high-workload conditions Successful task performance, adequate situation awareness, and manageable workload were used to validate the proposed minimum staffing level was acceptable Integrated system validation (ISV) used performance-based tests to determine whether hardware, software, and personnel elements meet performance requirements.

Trained personnel perform preplanned scenarios, which consisted of a broad sample of normal, abnormal, and emergency plant events, in a multi-module control room simulator where all units are simultaneously and independently modeled with connected inputs of shared systems.

holtec.com l smrllc.com l Page 13 Simulator Development

((

((

holtec.com l smrllc.com l Page 14 Simulator Development The bulk of HFE work including OER, FRA/FA, TA and initial Staffing and Qualification work will continue with the use of the Engineering Simulator and single unit Desktop Scaled Simulator with incorporated HSI.

A dual unit simulator will be employed to validate the Staffing plan and integrated system design based on the intended Concept of Operations.

holtec.com l smrllc.com l Page 15 Open Forum

holtec.com l smrllc.com l Page 16 Backup Slides

holtec.com l smrllc.com l Page 17 Common Systems

((

))

holtec.com l smrllc.com l Page 18 Design Configuration

((

((

holtec.com l smrllc.com l Page 19 Plant-Referenced Simulator 10CFR 55.4 "Plant-referenced simulator means a simulator modeling the systems of the reference plant with which the operator interfaces in the control room, including operating consoles, and which permits use of the reference plants procedures.

RG 1.149 Expected plant response to operator input and to normal, transient, and accident conditions Sufficiency in scope and fidelity to allow conduct of the evolutions associated with operating test content and licensed operator requalification program on-the-job training, applicable to the design of the reference plant Simulator fidelity has been demonstrated so that significant control manipulations are completed without procedural exceptions, simulator performance exceptions, or deviation from the approved training scenario sequence.

holtec.com l smrllc.com l Page 20 Simulator Development From NUREG/CR-6838, Using in-simulator studies for staffing plan validation will often be limited by simulator availability Requires trained operators who understand the advanced design and HSI innovations compared to conventional plants Simulators with lower levels of fidelity may be used to provide supporting data