RS-23-086, Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval
| ML23240A390 | |
| Person / Time | |
|---|---|
| Site: | Quad Cities |
| Issue date: | 08/28/2023 |
| From: | Lueshen K Constellation Energy Generation |
| To: | Office of Nuclear Reactor Regulation, Document Control Desk |
| References | |
| RS-23-086 | |
| Download: ML23240A390 (1) | |
Text
{{#Wiki_filter:4300 Winfield Road Warrenville, IL 60555 630 657 2000 Office August 28, 2023 10 CFR 50.55a RS-23-086 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001 Quad Cities Nuclear Power Station, Units 1 and 2 Renewed Facility Operating License Nos. DPR-29 and DPR-30 NRC Docket Nos. 50-254 and 50-265
Subject:
Relief Request I5R-26, Inservice Inspection Program Relief Request Regarding Examination Coverage for the Fifth Inservice Inspection Interval In accordance with 10 CFR 50.55a, "Codes and standards," paragraph (g)(5)(iii), Constellation Energy Generation (CEG), LLC requests U.S. Nuclear Regulatory Commission (NRC) approval of the attached relief request associated with the fifth inservice inspection interval (ISI) for Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2. Relief is requested due to the impracticality of satisfying the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," due to plant design. The relief request is based on the design configuration limitations that precluded completion of full Code examination requirements of ASME Class 1 and 2 components during the fifth interval. The QCNPS fifth ten-year ISI program plan was developed in accordance with ASME Code, Section XI, 2007 Edition through 2008 Addenda. The fifth ISI interval for QCNPS ended May 17, 2023. CEG requests authorization of this request by August 28, 2024. There are no regulatory commitments contained within this letter. Should you have any questions concerning this letter, please contact Ms. Rebecca L. Steinman at 779-231-6162. Respectfully, Kevin Lueshen Sr. Manager Licensing Constellation Energy Generation, LLC Constellation Lueshen, Kevin Digitally signed by Lueshen, Kevin Date: 2023.08.28 11:34:28 -05'00'
U.S. Nuclear Regulatory Commission August 28, 2023 Page 2 Attachments:
- 1. 10 CFR 50.55a Relief Request I5R-26, Revision 0
- 2. Additional Details and Supporting Information - Unit 1
- 3. Additional Details and Supporting Information - Unit 2 cc:
Regional Administrator - NRC Region III NRC Senior Resident Inspector - Quad Cities Nuclear Power Station
ATTACHMENT 1 Quad Cities Generating Station Units 1 & 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Impracticality-- Page 1 of 15
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 2 of 15 1. ASME Code Component(s) Affected Code Class: 1 & 2
References:
IWB-2500, Table IWB-2500-1, IWC-2500, Table IWC-2500-1, ASME Code Case N-578-1, Table 1 Examination Category: B-A, B-D, R-A Item Number: B1.12, B1.40, B1.51, B3.90, R1.20
== Description:== Limited Examination Coverage Component Number: See Tables A and B for a list of Component IDs
===2. Applicable Code Edition and Addenda=== The fifth 10-Year Interval of the Quad Cities Nuclear Power Station (QCNPS), Units 1 and 2 Inservice Inspection (ISI) Program ended on May 17, 2023 and was based on the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code, Section XI, "Rules for lnservice Inspection of Nuclear Power Plant Components," 2007 Edition with the 2008 Addenda. QCNPS, Units 1 and 2 maintain the responsibility to ensure examinations were performed in accordance with the requirements of ASME Section XI, Appendix VIII, "Performance Demonstration for Ultrasonic Examination Systems," as amended and mandated by 10 CFR 50.55a and as modified by the Performance Demonstration Initiative (PDI) Program description. In the case of limited examinations, efforts were made to obtain additional examination coverage. Tables A and B identify whether each listed best effort examination was performed in accordance with the requirements of ASME Section XI, Appendix VIII. Attachments 2 (Unit 1) and 3 (Unit 2) provide additional details and information supporting this request.
===3. Applicable Code Requirements=== IWA-2200(c) requires that "All nondestructive examinations of the required examination surface or volume shall be conducted to the maximum extent practical. When performing VT-1, surface, radiographic, or ultrasonic examination on a component with defined surface or volume, essentially 100% of the required surface or volume shall be examined. Essentially 100% coverage is achieved when the applicable examination coverage is greater than 90%; however, in no case shall the examination be terminated when greater than 90% coverage is achieved, if additional coverage of the required examination surface or volume is practical." Table IWB-2500-1, Examination Category B-A, Item Number B1.12, requires a volumetric examination of the Reactor Vessel shell longitudinal welds in accordance with Figure IWB-2500-2. The extent of examination is essentially 100% of the required examination volume and surface, as specified in IWA-2200(c).
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 3 of 15 Table IWB-2500-1, Examination Category B-A, Item Number B1.40, requires a volumetric and surface examination of the Reactor Vessel closure head-to-flange weld in accordance with Figure IWB-2500-5. The extent of examination is essentially 100% of the required examination volume and surface, as specified in IWA-2200(c). Table IWB-2500-1, Examination Category B-A, Item Number B1.51, requires a volumetric examination of Reactor Vessel repair welds within the beltline region in accordance with Figures IWB-2500-1 and IWB-2500-2 for base metal repairs where the repair depth exceeds 10% nominal of the vessel wall thickness. The extent of examination is essentially 100% of the required examination volume and surface, as specified in IWA-2200(c). Table IWB-2500-1, Examination Category B-D, Item Number B3.90, requires a volumetric examination of the Reactor Vessel nozzle-to-vessel welds in accordance with Figure IWB-2500-7. The extent of examination is essentially 100% of the required examination volume, as specified in IWA-2200(c). The Risk-Informed ISI Program (RI-ISI) in accordance with EPRI Topical Report TR-112657, Revision B-A and ASME Code Case N-578-1 was used during the fifth ISI Interval per Relief Request I5R-02, which was authorized on September 30, 2013. The extent of examination requirement for Examination Category R-A, Item Number R1.20 per Table 1 of ASME Code Case N-578-1 requires a volumetric examination of essentially 100% of the required volume of the RI-ISI weld in accordance with Figures IWB-2500-7(a), IWB-2500-8(c), IWB-2500-9, IWB-2500-10, or IWB-2500-11, as applicable.
===4. Impracticality of Compliance=== In accordance with 10 CFR 50.55a(g)(5)(iii), relief is requested on the basis that conformance with these ASME Section XI requirements is impractical since conformance would require extensive structural modifications to the component or the surrounding structure. Due to the original design of these components, QCNPS, Units 1 and 2 is unable to satisfy the ASME Section XI requirements to perform a surface or volumetric examination to the extent required for welds and welded attachments (greater than 90% of the required examination volume or area) identified in Tables A and B due to physical component configuration, interference from permanent plant equipment, single-sided access, etc. QCNPS, Units 1 and 2 would incur significant engineering, material, and installation costs to perform such modifications without a compensating increase in the level of quality and safety. Therefore, relief is requested on the basis that the ASME Section XI requirements to examine these components are impractical. During outages, when situations were identified where coverage was an issue, QCNPS, Units 1 and 2 personnel reviewed the systems for alternatives. For the RI-ISI weld population, Examination Category R-A welds, submitted in this relief request, a case by case review was performed to determine whether additional or alternative welds could have been examined to supplement the reduced volumetric coverage examination. It
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 4 of 15 was determined that there were no other welds to select that would have resulted in better coverage. This determination was made based on comparison of configurations, delta core damage frequency (CDF) values, the systems involved, and inspection history. Tables A and B provide a summary of the examination limitations for each component for which relief is requested. The tables also indicate the outage the component was examined, the coverage percentage obtained for each component, and other pertinent design information. This table is the cumulative list of the limited ASME Section XI examinations performed during the fifth ISI Interval. Attachments 2 and 3 provide coverage plots which were extracted from the non-destructive examination (NDE) summary sheets that detail the examination limitations. Based on the above explanation, QCNPS, Units 1 and 2 requests relief from the ASME Section XI requirement of IWA-2200(c) that requires at least 90% coverage for volumetric and surface examinations for the items included in this request, based on the position that compliance with the required examination coverage is impractical.
===5. Burden Caused by Compliance=== Compliance with the applicable ASME Section XI volumetric and surface examination requirements can only be accomplished by redesigning and refabricating the subject and/or surrounding components. Based on this, the ASME Section XI requirements are deemed impractical in accordance with 10 CFR 50.55a(g)(5)(iii).
===6. Proposed Alternative and Basis for Use=== QCNPS, Units 1 and 2 has performed the ASME Section XI required examinations to the maximum extent practical (Code Coverage), or best effort, which are documented in Tables A and B. Due to the physical interferences or component geometry, there are no alternative examination techniques currently available to increase examination coverage. There were no cases in any of the listed examinations where the components outside diameter surface features (i.e., weld crowns, weld shrinkage, surface roughness, etc.) could have been conditioned to obtain the required coverage without major modification to the components. During the fifth ISI Interval, periodic system pressure tests that include VT-2 visual examinations were performed in accordance with ASME Section Xl, Table IWB-2500-1, "Examination Category B-P for Class 1 pressure retaining welds and components during each refueling outage," and Table IWC-2500-1, "Examination Category C-H for Class 2 pressure retaining welds and components during each inspection period." These periodic system pressure tests and VT-2 examinations provided additional assurance that the structural and leak-tight integrity of the subject components was maintained throughout the fifth ISI Interval. Volumetric and/or surface examinations were performed to the maximum extent practicable on components in this request, as required by the ASME Section XI ISI
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 5 of 15 Program, the RI-ISI Program, and other applicable augmented examination programs (e.g., Intergranular Stress Corrosion Cracking (IGSCC) Program).
===7. Duration of Proposed Alternative=== Relief is requested for the fifth ISI Interval for QCNPS, Units 1 and 2, which ended on May 17, 2023.
===8. Precedents=== The following similar end of interval impracticality relief requests have been previously authorized by the NRC: Quad Cities, Units 1 and 2 Fourth ISI Interval Relief Request I4R-20 was authorized per NRC Safety Evaluation (SE) dated October 30, 2015 (ADAMS Accession No. ML15289A415). Watts Bar Nuclear Plant, Unit 1 Second ISI Interval Relief Request 1-ISI-21 was authorized per NRC SE dated April 12, 2019 (ADAMS Accession No. ML19071A009). Limerick Generating Station, Units 1 and 2 Third ISI Interval Relief Request I3R-23 was authorized per NRC SE dated August 7, 2018 (ADAMS Accession No. ML18192C172). Surry Power Station Unit 2 Fourth ISI Interval Relief Requests LMT-R01, LMT-C02, and LMT-C03 were authorized per NRC SE dated February 17, 2017 (ADAMS Accession No. ML16365A118).
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 6 of 15 Table A Quad Cities Generating Station, Unit 1 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks N4A NOZ Feedwater Nozzle-to-Shell Weld on Reactor Pressure Vessel (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q1R24 SA-336 to SA-302B Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 2 -Pg Nos. 2-4) N4B NOZ Feedwater Nozzle-to-Shell Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q1R24 SA-336 to SA-302B Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 2 -Pg Nos. 5-7) N4C NOZ Feedwater Nozzle-to-Shell Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q1R24 SA-336 to SA-302B Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 2 -Pg Nos. 8-10) N4D NOZ Feedwater Nozzle-to-Shell Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q1R24 SA-336 to SA-302B Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 2 -Pg Nos. 11-13) N2C NOZ Recirculation Nozzle-to-Shell Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q1R25 SA-336 to SA-302B Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 78.7% Yes The limitation was due to the configuration of the nozzle. No recordable indications were detected. (Att. 2 -Pg Nos. 14-16)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 7 of 15 Table A Quad Cities Generating Station, Unit 1 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks 03-F1A Nozzle-to-Safe End Weld (RPV) IWB-2500-8(c), Volumetric (UT) 1 R-A R1.20 Q1R25 SA-336 CL F8 to A508 Weld 5.25"/0.75" 30°/2.25/Shear 45°/2.25/Shear 45°/2.0/Long 60°/2.0/Long 34°/1.5/Long 89.7% Yes The limitation was due to the configuration of the safe end. No recordable indications were detected. (Att. 2 -Pg Nos. 17-18) 1015B-17R Elbow-to-Valve Weld in Residual Heat Removal System (RHR) IWC-2500-7(a) Volumetric (UT) 2 R-A R1.20 Q1R25 A234 Gr. WPB to A216 Gr. WCB Weld 14"/0.375" 45°/5.0/Shear 60°/5.0/Shear 70°/5.0/Shear 55.49% Yes The limitation was due to the configuration. Single-sided examination. A 360° indication (attributed to ID geometry) was detected. (Att. 2 -Pg Nos. 19-20) 1016C-2R Pipe-to-Valve Weld (RHR) IWC-2500-7(a) Volumetric (UT) 2 R-A R1.20 Q1R25 A106, Gr. B to A216 Gr. WCB Weld 14"/0.375" 45°/5.0/Shear 60°/5.0/Shear 70°/5.0/Shear 84.64% Yes The limitation was due to the configuration. Two recordable indications were detected and met the acceptance standards. (Att. 2 -Pg Nos. 21-22) 1016C-3R Valve-to-Pipe Weld (RHR) IWC-2500-7(a) Volumetric (UT) 2 R-A R1.20 Q1R25 A216 Gr. WCB to A106, Gr. B Weld 14"/0.375" 45°/5.0/Shear 60°/5.0/Shear 70°/5.0/Shear 84.64% Yes The limitation was due to the configuration. Two recordable indications were detected and met the acceptance standards. (Att. 2 -Pg Nos. 23-24) 1016D-1R Valve-to-Pipe Weld (RHR) IWC-2500-7(a) Volumetric (UT) 2 R-A R1.20 Q1R25 A216 Gr. WCB to A106, Gr. B Weld 14"/0.375" 45°/5.0/Shear 60°/5.0/Shear 70°/5.0/Shear 78.17% Yes The limitation was due to the configuration. A 360° indication (attributed to ID geometry) was detected. (Att. 2 -Pg Nos. 25-26)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 8 of 15 Table A Quad Cities Generating Station, Unit 1 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks RPV-VSC1-55 RPV COURSE #1 55 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 83.73% Yes The limitation was due to the weld proximity to the Jet Pump Baffle Plate and N-8A Nozzle. No recordable indications were detected. (Att. 2 -Pg Nos. 27-28, 39) RPV-VSC1-197 RPV COURSE #1 197 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 38.20% Yes The limitation was due to the weld proximity to the Core Shroud Tie Down Bracket and proximity of the Jet Pump Baffle Plate. Non-relevant mid-wall plate segregates were noted. (Att. 2 -Pg Nos.29-30,39) RPV-VSC2-22 RPV COURSE #2 22 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 57.07% Yes The limitation was due to the weld proximity to the Core Shroud Tie Down Bracket and Jet Pump Bracket. Non-relevant mid-wall plate segregates were noted. (Att. 2 -Pg Nos. 31-32, 39) RPV-VSC3-77 RPV COURSE #3 77 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 75.21% Yes The limitation was due to the weld proximity to Feedwater and Core Spray Spargers. Three indications were detected, sized, and evaluated in accordance with the acceptance criteria of Section XI, 2007 Edition with 2008 Addenda and were found to be acceptable. (Att. 2 -Pg Nos. 33-34, 39)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 9 of 15 Table A Quad Cities Generating Station, Unit 1 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks RPV-VSC3-197 RPV COURSE #3 197 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 73.59% Yes The limitation was due to the weld proximity to Feedwater and Core Spray Spargers. One indication was detected, sized, and evaluated in accordance with the acceptance criteria of Section XI, 2007 Edition with 2008 Addenda and was found to be acceptable. (Att. 2 -Pg Nos. 35-36, 39) RPV-VSC3-317 RPV COURSE #3 317 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q1R25 SA302, Gr. B to SA302, Gr. B Weld 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 78.58% Yes The limitation was due to the weld proximity to Feedwater and Core Spray Spargers. Non-relevant mid-wall plate segregates and minor outside surface irregularities were noted. (Att. 2 -Pg Nos. 37-39) BMR-167-305 RPV Weld Beltline Repair Area at 167°, Elevation 307.0 inches (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.51 Q1R25 SA302, Gr. B 6.125" Shell Thickness Automated Phased-Array UT 60°-80° (Long) 40°-50° (Shear) 30°-60° (Long) 0° (Long) 66.40% Yes The limitation was due to the weld proximity to the Jet Pump Riser Bracket. No recordable indications were detected. (Att. 2 -Pg Nos. 40-42)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 10 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks N2A NOZ Recirculation Nozzle-to-Vessel Weld on Reactor Pressure Vessel (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 77.9% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 2-4) N2B NOZ Recirculation Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R24 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 80.3% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 5-7) N2D NOZ Recirculation Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 77.9% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 8-10) N2E NOZ Recirculation Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 77.9% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 11-13) N3A NOZ Main Steam Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R24 SA302, Gr. B to SA336 Weld 20"/6.125" 60°/3.0/Long 55°/1.0/Shear 77.7% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 14-16)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 11 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks N4A NOZ Feedwater Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 17-19) N4B NOZ Feedwater Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 20-22) N4C NOZ Feedwater Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 23-25) N4D NOZ Feedwater Nozzle-to-Vessel Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R22 SA302, Gr. B to SA336 Weld 12"/6.125" 60°/3.0/Long 55°/1.0/Shear 74.4% Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 26-28) N5A NOZ Core Spray Nozzle-to-Shell Weld (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R25 SA302, Gr. B to SA336 Weld 10"/6.125" 60°/3.0/Long 55°/1.0/Shear 73.9% Yes The examination was limited due to the insulation support bracket and nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 29-31)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 12 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks N6A NOZ Head Spray Nozzle-to-RPV Head (RPV) IWB-2500-7 Volumetric (UT) 1 B-D B3.90 Q2R23 SA302, Gr. B to A508 Weld 6"/4.125" 60°/3.0/Long 55°/1.0/Shear 70°/1.0/Shear 59.1%. Yes The examination was limited due to the nozzle configuration. No recordable indications were detected. (Att. 3 -Pg Nos. 32-34) RPV-THHF Top Head-to-Flange Weld (RPV) IWB-2500-5 Volumetric (UT) 1 B-A B1.40 Q2R24 SA302, Gr. B to SA336 Weld 251"/4" 60°/3.0/Long 45°/1.0/Shear 45°/2.25/Shear 76.3% Yes The examination was limited due to the flange configuration. Five (5) recordable indications were detected. The flaw sizes showed no evidence of growth from previous examinations, are bounded by the existing analytical evaluation, and were evaluated as acceptable. Surface examination (Magnetic Particle) performed during Q2R24 was acceptable. (Att. 3 -Pg Nos. 35-37) RPV-VSC1-77 RPV COURSE #1 77 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 89.3% Yes The examination was limited due to clearance between the jet pump diffusers and the vessel wall. No recordable indications were detected. (Att. 3 -Pg Nos. 38-41)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 13 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks RPV-VSC1-197 RPV COURSE #1 197 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 42.5% Yes The examination was limited due to the lower shroud repair support. No recordable indications were detected. (Att. 3 -Pg Nos. 42-45) RPV-VSC1-317 RPV COURSE #1 317 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 78.8% Yes The examination was limited due to the proximity of the jet pump 20 sensing line bracket and the N1 penetration. One recordable indication was detected during this examination. The indication was unchanged from the previous examination. (Att. 3 -Pg Nos. 46-51) RPV-VSC2-22 RPV COURSE #2 22 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 58.3% Yes The examination was limited due to the proximity of the shroud repair. The upper portion of the weld was completely obstructed due to the design and location of the upper repair support. No recordable indications were detected. (Att. 3 -Pg Nos. 52-56)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 14 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks RPV-VSC3-77 RPV COURSE #3 77 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 71.3% Yes The examination was limited due to the feedwater spargers and core spray piping. No recordable indications were detected. (Att. 3 -Pg Nos. 57-60) RPV-VSC3-197 RPV COURSE #3 197 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 67.7% Yes The examination was limited due to the feedwater spargers, core spray piping, and guide rod brackets. No recordable indications were detected. (Att. 3 -Pg Nos. 61-64) RPV-VSC3-317 RPV COURSE #3 317 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 76.2% Yes The examination was limited due to the feedwater spargers and core spray piping. No recordable indications were detected. (Att. 3 -Pg Nos. 65-68)
ATTACHMENT 1 10 CFR 50.55a Relief Request I5R-26, Revision 0 Proposed Alternative in Accordance with 10 CFR 50.55a(g)(5)(iii) --Inservice Inspection Practicality Page 15 of 15 Table B Quad Cities Generating Station, Unit 2 List of Components with Limited Examination Coverage Component ID Weld Description (System)1 Exam Requirements (Figure No.) and Method Class / Exam Category / Item Number Outage Examined Material of Construction Diameter / Thickness Exam Angle / Frequency (MHz) / Mode Actual Coverage Appendix VIII Qualified Exam Remarks RPV-VSC4-219 RPV COURSE #4 219 DEG Vertical Shell Weld (RPV) IWB-2500-2 Volumetric (UT) 1 B-A B1.12 Q2R26 SA302, Gr. B to SA302, Gr. B Weld 251"/6.125" Automated UT 45° shear wave for Supplement 4 and 6 examinations. 60° longitudinal wave for Supplement 4 examinations. 81.3% Yes The examination was limited due to the dryer support lug and N11B nozzle. Coverage calculations in the area of these obstructions were achieved with single side access. No recordable indications were detected. (Att. 3 -Pg Nos. 69-73)
ATTACHMENT 2 Quad Cities Generating Station 10 CFR 50.55a Relief Request I5R-26 Additional Details and Supporting Information Unit 1 Page 1 of 42
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 2 of 42 N4A NOZ (Feedwater Nozzle to RPV Weld) I I I I I I I / 4.8" 60"T N4 - Feedwater Nozzle GO* S6 Exam Volume= 31.2 Sq. In. Go* S4 Exam Volume 4.0 Sq. In. Inner 15% T S5 Exam Volume= 4.0 Sq. In. 60" S6 Exam Volume Achieved - 13.2 Sq. In. 60* S4 Exam Volume Achieved= 4.0 Sq. In. Inner 1S% T S5 Exam Velum e Achieved= 4.0 Sq. In. Examination volume i.a.w. Code Cose N-613-1 Circumferential examination of the outer 85% T is not required io.w. the 2007 Edition w/ 2008 Addenda. 13.7" 60"T N4 Nozzle to Shell Scan Limits at Top Dead Center
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 3 of 42 N4A NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Weld Length = 360.0 Exam Volume= 35.2 60° T-Scan (56) I A 60° T-Scan (54) I A IRS P-Scan 1S51 I A 60° T-Scan (56) I 60° T-Scan (54) I IRS P-Scan (551 I 60° T-Scan (56) I 60° T-Scan (511) I IRS P-Scon (551 I 60° T-Scan (56) I 60° T-Scan (S4) I IRS P-Scon 1:,~J I 60° T-Scon (S6) I 60° T-Scon (S4) I IRS P-Scon !SSJ I Quad Cities Unit-1, 1QR24 N4A N02 Nozzle to Shell Weld CODE CROSS-SECTIONAL AREA Required Exam Area Scanned TOTAL CODE COVERAGE Percent of Area Weld Length Area Sq. in. Sq. In. Achieved Achieved 31.2 13.2 37.5% 360 4.0 4.0 11.4% 360 4.0 4.0 100.0% 360 o/o Total Composite Coverage ~ Comments: A* Manual scanning limited due to the nozzle configuration. Percent Achieved 18.8% 5.7% 50.0% 74.4% Rev. 2-20-20111 Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note* Roundin methods ma affect colculoted values. 54 - Su lement 4, 55
- Supplement 5, 56 Supplement - 6. Weld length in degrees.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 4 of 42 N4A NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Comments: Ultrasonic examine ion results were acceptable to the requirements of ASME B&PV Code Section XI, 2007 Edition with the 2008 Addenda, as modified by the POI program descrip ion and the Federal Register, Port 11, Nuclear Regulatory Commission, 10 CFR Port 50 for Category B-D Reactor Pressure Vessel (RPV) Assembly Welds. anuol radial scans were performed in accordance with procedure GEH-UT-300 Rev. 12 using 60° Refracted Longi udinol (R )waves. ozzle Inner 15%T circ scans were performed in accordance with GEH-UT-311 Rev. 19 using model validated search unit angles. Manual scanning was performed from the vessel OD surface and was limited due to the nozzle configure ion. An insulation panel limited access during the initial examination recorded on C-019. This limitation was removed and e previously limited area examined and recorded on C-037. o relevant indications were recorded. Achieved coverage= 74.4%. Code Cose -613-1 applies.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 5 of 42 N4B NOZ (Feedwater Nozzle to RPV Weld) I I I I I I I / / 4.8-60"1' N4 - Feedwater Nozzle GO* S6 Exam Volume
- 31.2 Sq. In.
GO* S4 Exam Volume - 4.0 Sq. In. Inner 15%T SS Exam Volume
- 4.0 Sq. In.
Go* S6 Exam Volume Achieved= 13.2 Sq. In. Go* S4 Exam Volume Achieved = 4.0 Sq. In. Inner 15%T S5 Exam Volume Achieved = 4.0 Sq. In. Examination volume i.a.w. Code Cose N-613-1 Circumferential examino on of the outer 85%T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. 13.7' 60"1' N4 Nozzle to Shell Scan Limits at Top Dead Center
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 6 of 42 N4B NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Quad Cities Unit-1, 1QR24 N48 NOZ Nozzle to Shell Weld CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Percent of Area Weld Length Weld Length = Exam Volume= 360.0 35.2 Required Exam Area Sq. in. Area Scanned Sq.In. Achieved Achieved 60° T-Scon (56) A 31.2 13.2 37.5% 360 60° T-Scon (54) A 4.0 4.0 11.4% 360 IRS P-Scon {55) A 4.0 4.0 100.0% 360 60° T-Scon 156) 60° T-Scon (S4) IRS P-scon IS!:>) G0° T-Scon (S6) G0° T-Scon (54) IRS P-Scon 155) G0° T-Scon (56) 60° T-Scon (54) IRS P-Scon {SSJ G0° T-Scon (56) G0° T-Scon (54) IRS P-Scon l!:>!:>J % Total Composite Coverage = Comments: A - Manual scanning limited due to the nozzle configuration. Percent Achieved 18.8% 5.7% 50.0% 74.4% Rev. 2*20--201'* Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. 54 - Supplement 4. S5 - Supplement 5, 56 - Supplement 6. Weld length in degrees.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 7 of 42 N4B NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Comments: Ultrasonic examino ion results were acceptable to the requirements of ASME B&PV Code Sec ion XI. 2007 Edition with the 2008 Addenda, as modified by the POI program description and the Federal Register, Part II, Nuclear Regulatory Commission, 10 CFR Port 50 for Category 8-D eoctor Pressure Vessel (RPV) Assembly Welds. Manual radial scans were performed in accordance with procedure GEH-UT-300 Rev. 12 using 60° Refracted Longitudinal (RL) waves. ozzle Inner 15%T circ scans were performed in accordance with GEH-UT-311 Rev. 19 using model validated search unit angles. anual scanning was performed om the vessel OD surface and was limited due to the nozzle config ration. o relevant indications were recorded. Ac ieved coverage = 74.4%. Code Cose N-613-1 applies.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 8 of 42 N4C NOZ (Feedwater Nozzle to RPV Weld) / I I I I I I I 4.e* 60°T N4 - Feedwater Nozzle 60° S6 Exam Volume= 31.2 Sq. In. 60" S4 Exam Volume - 4.0 Sq. In. Inner 15%T SS Exam Volume = 4.0 Sq. In. 60* S6 Exam Volume Achieved= 13.2 Sq. In. 60° S4 Exam Volume Ach ved = 4.0 Sq. In. Inner 15%T S5 Exam Volume Achieved = 4.0 Sq. In Examination volume i.o.w. Code Cose -613-1 Circum eren *01 examination of the outer 85%T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. 13.7* 60°T N4 Nozzle to Shell Scan Limits at Top Dead Center
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 9 of 42 N4C NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Weld Length = Exam Volume = 60° T-Scon (561 60° T-Scon (541 IRS P-Scon (551 60°T-Scon (561 60°T-Scon (541 IRS P-Scon (551 60° T-Scon (56) 60°T-Scon (54) IRS P-Scon 1:.::.1 60° T-Scon (561 60°T-Scon (541 IRS P-Scon (551 60°T-scon (561 60°T-Scon (541 IRS P-Scon 1551 360.0 35.2 A A A Quad Cities Unit-1, 1QR24 N4C NOZ Nozzle to Shell Weld CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 31.2 4.0 4.0 Area Scanned Sq. In. 13.2 4.0 4.0 Percent of Area Achieved 37.5% 11.4% 100.0% TOTAL CODE COVERAGE Weld Length Achieved 360 360 360 % Total Composite Coverage= Comments: A - Manual scanning limited due to the nozzle configuration. Percent Achieved 18.8% 5.7% 50.0% 74.4% Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ o Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S4 - Supplement 4, 55 - Supplement 5, S6 Supplement - 6. Weld length in degrees.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 10 of 42 N4C NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Comments: Ultrosonic examination results were acceptoble to the requirements of ASME B&PV Code Section XI, 2007 Edition with the 2008 Addendo, os modified by e POI progrom description and the Federal Register, Part 11, Nuclear Regulatory Commission, 10 CFR Part 50 for Category 8-D Reactor Pressure Vessel (RPVI Assembly Welds. anual radial scans were performed in accordance with procedure GEH-UT-300 Rev.12 using 60° Refracted Longi udinal (RU waves. ozzle Inner 15%T circ scans were performed in accordance with GEH-UT-311 Rev. 19 using model validated search unit angles. Manual sconni g was performed from the vessel OD surface and was limited due to the nozzle configuration. o relevan indications were recorded. Achieved cove age= 74.4%. Code Case -613-1 applies.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 11 of 42 N4D NOZ (Feedwater Nozzle to RPV Weld) I I I I I I I / / 4.8" 60.,. N4 - Feedwater Nozzle 60° 56 Exom Volume 3.2 Sq. In. 60" S4 Exom Volume = 4.0 Sq. In. Inner 15'l6T 55 Exom Volume
- 4.0 Sq. In.
60° S6 Exom Volume Achieved= 13.2 Sq. In. 60° 54 Exom volume Achieved = 4.0 Sq. In. Inner 15'l6T SS Exom Volume Achieved= 4.0 Sq. In. E><ominotion volume i.o.w. Code Cose -613-1 Circumferential exomino *on of the outer 85%T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. 13.7" 60.,. N4 ozzle to Shell Scan Limits at Top Dead Center
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 12 of 42 N4D NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Weld Length = Exam Volume= 60°T-Scan (S6) 60°T-Scan (S4) IRS P-Scan C>SJ 60°T-Scan (56) 60°T-Scan (54) IRS P-Scan {SSJ 60°T-Scan (56) 60°T-Scan IS4) IRS P-Scan (551 60° T-Scan IS6) 60°T-Scon IS4) IRS P-Scon (SS) 60°T-Scon IS6) 60° T-Scon (S4) IRS P-Scon \SSJ 360.0 35.2 A A A Quad Cities Unit-1, 1QR24 N4D NOZ Nozzle to Shell Weld CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 31.2 4.0 4.0 Area Scanned Sq. In. 13.2 4.0 4.0 Percent of Area Achieved 37.5% 11.4% 100.0% TOTAL CODE COVERAGE Weld Length Achieved 360 360 360 % Total Composite Coverage = Comments: A - Manual scanning limited due to the noule configuration. Percent Achieved 18.8% 5.7% 50.0% 74.4% flev. Z*20-ZOl4 Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S4 - Supplement 4, 55 - Supplement 5, 56 Supplement-6. Weld length in degrees.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 13 of 42 N4D NOZ (Feedwater Nozzle to RPV Weld) - (Contd) Comments: Ultrasonic examination results were acceptable to the requirements o ASME B& V Code Section XI. 2007 Edition with the 2008 Addenda, as modified by t e POI program descrip ion and the Federal Register, Part 11. uclear Reg latory Commission, 10 CFR Port 50 for Category B-D Reactor Pressure Vessel (RPV) Assembly Welds. Manual radial scans were performed in accordance with procedure GEH-UT-300 Rev. 12 using 60° Ref acted Langi udinol (Rll waves. Nozzle Inner 15%T circ scans were performed in accordance with GE -UT-311 Rev. 19 usi g model validated search unit angles. Manual scanning was performed f om the vessel OD surface and was limited due to the nozzle configure *on. No relevant indications were recorded. Achieved coverage= 74.4%. Code Cose N-613-1 applies.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 14 of 42 N2C NOZ / I Quad Cities Unit 1 N2 - Recirculation Inlet Nozzle ea* NS Exam Volume = 19.1 Sq. In. ea* FV S6 Exam Volume= 26.9 Sq. In. ea* FV S4 / 15%T IRS Exam Volume= 5.8 Sq. In ea* NS T-Scan achieved = 1.4 Sq. In. ea* FV S6 T-Scan achieved = 22.5 Sq. In. ea* FV S4 T-Scan achieved = 5.8 Sq. In. Inner 15%T IRS-Scan achieved= 5.8 Sq. In. (By modeling.) so*r so0r 60°T I I I 4// / ___ //
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 15 of 42 N2C NOZ (Contd) Weld Length = Exam Volume = 60° T-Scan (S6) 60° T-Scon (S4) IRS P-Scon {S5) 60° T-Scon (S6) 60° T-Scan (S4) IKS P-Scan IS!>) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan {SS) 60° T-Scan 1S61 60° T-Scon 1S4) IRS P-Scan ISSJ 60° T-Scon 1S61 60° T-Scon (S4) IRS P-Scan ISSJ 360. 51.8 A A A Quad Cities Unit 1 N2C Recirculation Inlet Nozzle CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 46.0 5.8 5.8 Area Examined 23.9 5.8 5.8 TOTAL CODE COVERAGE Percent of Area Weld Length Examined Examined 46.1% 360 11.2% 360 100.0% 360 % Total Composite Coverage = Comments: A - Manual scanning was restricted due to the nozzle configuration. Percent Examined 23.1% 5.6% 50.0% 78.7% Rw llU/IOla Note -This coverage colculotion is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda. 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Nole - Rounding methods may artect calculated values. S4/ 5/6 - Supplement 4. 5 or 6. Weld length 1n degrees.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 16 of 42 N2C NOZ (Contd) Comments* UI roson,c e amino ion results ere occep able o the re u1rements of AS E B PV Code Secuon XI, 2007 Edi 10n, the 2008 Addenda. as modi,ed by he POI program descnp,on ond he Federal eg,s er. Port 11, ucleor Regula ory Commission. 0 CFR Po SO or Co egory B-0. Full Pene ro,on elded ozzles 1n Vessels. Manual ronsverse scanning. as performed in ccordonce,11th procedure GEH-UT-300 V 12 NI h OR 3-3 -12, and -25. using a 60° RL ozzle Inner 5%T circumferen 101 scans ere pe armed tn accordance, procedure GEH-UT-3 V. 19 1th ORR -2 using model vahda ed search uni angles. Manual scanning s per armed rom e vessel OD sur ace ond w s res nc ed due o he nozzle con 19 ra 10n. o recordable ind1cot1ons observed Achieved coverage= 78.7%. Code Cose N-613-2 applies.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 17 of 42 03-F1A (Nozzle to Safe End Weld) ~" .o() No counterbore detected Total volume = W X H Total Volume 2.9" K 0.3" = 0.87 in2 Total Axial Volume Achieved 100% Axial coverage Total Circ Volume Achieved (2.9" x 0.3") - 0.18": 0.69 in2 (0.69 in2 / 0.87 in2) K 100 = 79.3% circ coverage (100% + 79.3%) / 2 = 89. 7% total coverage achieved C..DV£(l,._Ae:,f PLCT l.o~ 1.0** -~**
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 18 of 42 03-F1A (Contd) l.o" .80' .~** .C\~f'. 91 .ss** \o~*fo AXIAL CDvEq_f\(~r_ ACl11E v£D l.o" 1.0 .ss**
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 19 of 42 1015B-17R (Elbow to RHR System valve weld) lDl5B-l7K VALVf tLBo"{ VALVf ELsow
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 20 of 42 1015B-17R (Contd) I,, I I ~l!L M5d+ ;- £o/t~5[ttL 11 ~0.1.s");a]J -r [(r.,.LfS"+o,s) x[(o.15'"-rl>.~S')/a JJ = o.~ I~.,,..,* Ax, At_ c,vr.:llAG-f:,;. [o,q!l!i ((o.,1 ro,LS1/a]! +-O:o->5"",< o.~~);a.J :-o., '17 so..,N, 0,31 (o.1'fi5'l-.1~/~~a.,..J.)1co;; l/1.L/l c::,nc. Covf:tc?A-c':,~ ~ C.<o.~-t0,~5)/~)"*i" :--o. 113 $Q, '"'.
- t. J-(o., 13 ~.~. /a.'b, 54.,~.>J,~: ~'3..55"
'ra1"",t:;L C~Vf::a.A-6f: ': (47, '-/:J. -r- (o'2. S f!)/:l o: 5'5°,4 '7 /2
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 21 of 42 1016C-2R (RHR pipe to valve weld) P1 PE. f LO w'
,r--~-'-1 -~
/ /
~ -------
l.,3iJ*' ).. 3/of' 3.83~" 4,:537 5.,'138 11 ELO\v / / ------ VALVE {,.() II 1,o VALVE {,.() IJ 1,o"
1016C-2R (Cont'd) I ATTACHMENT 2 10 CFR 50.55a Relief Request ISR-26, Revision 0 Additional Details and Supporting Information - Unit 1 c,A L A. - A _ 1 ' c... r I C> Page 22 of 42 /h:. I
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 23 of 42 1016C-3R (RHR pipe to valve weld) VALVE P1PE f,d \ /
~-------
\JALVE ELQW Pl PE. /.O',,
ATTACHMENT 2 st ISR-26, Revision 0 10 CFR 50.55a Relief Requ~. Information - Unit 1 Additional Details and Suppo mg 1016C-3R (Cont'd) I I~ --/,C ~*, '- r,, ,. r"'J/ J ,..., ~ - .-. ;, y: L'-.., I' -0, -).,,_ -.i !: -'* *1 ~ . /
- ~G°j/ ].,-- : (.j,fv _. _
- IN.
( ( tt. TO (e., : ~ ~: I T -, I/(, t' l~L ,It\.;,
- ICG -
9,,, ¥ '.:) t-1.::,,. :a')/ ,,. f ..::- '/_ Page 24 of 42
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 25 of 42 1016D-1R (RHR pipe to valve weld) I OJ t>O - I CRJ Pr.PE ~ ~ I 'r ', I I. 1 I ~ "k
- .o ~('..
<>~ ~ ~ J> 1/4. ~ 0 6 6 C 0 Pr.PE.
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 26 of 42 1016D-1R (Contd) .f: 1 ( ~ .,~ J
- F.J./2 f,,
I., .,~. A I L. CJ,:, L * - .~~)/*.J,:i:'-o.,,
- t. I -(o.,
,/ o, * 'lj._, )11
- . ;j ~ 3i
-t- ~,-6 * ., I J = 78', J 7 1/4
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 27 of 42 RPV-VSC1-55 Weld C/L 524.50"11.\_+-__________ 1U_c~_~_7_~6_*_.. l.__ ____________ -++-_1_~_( __ /_.. 31_~_~_1* ___ 1 _______ 1 3_~_(_36T!_;;_;_6* __ 1 __ ----I CW-C3C4 ~* cr/~3.8.. 1* scr11l_42* 15cr1l{Jl*5s* 2 er /438.08" I 240" ~525.69" 330" fc722.83" f Nl
- =========~~t===:1::==========- *::==========:::;1c:;2;1============::::*1
~=::==~::1~============-=! ~===t- ~ 5;.(Jo.95l 45"/98.57" N11A I I 155*/405.22 N5B y 165"/361.41" N9
- =========~~t=============::::" ":::=======t==:::;c:;;=======::::::
225*/492.84" N11B I 215*/410_93* 245*/536.65" 275./602.36" 35./76.66" 55*/142.38" 95"/208.09" Weld C/L 391.50" -----------------------..--------------------i,,i----t--t+-1-i __________ _ CW-C2C3 ~ 22' /48.19" \_ 141' /308.84" 261"/571.69"-v l'\_323' /707,50" VSC2-22 VSC2-141 VSC2-261 VSC2-323 1,J-liLI~L..... 111"-; ffl-lL-"<I-Pj ~ -~,J-ir u-L~11µ-Jffl-L-"<I-Pj ~ ? ,J IL ,JUL ,J IL ,JUL 1.50" en_ 1 1 Ir l,,i t'~ ~ I~ ~* ~/\ ~ ~ ~ ~ ~ ~ I I ~~ 1,. - J I!. a;_ r l=D I ~ ~ I~ ~ ~~- ~- 1a:= =e>> ~- ~ ~ ~ ~ ~- I a:1= =i:n Weld C~~~s:'c~o*-------------+r---------------------------------------------- \ J -, h 'r i Weld C/L 125.50" LL-CW-LHC1 ~ 5*/J~95*
- \~
- ~>'= -
~ li! ~ h h 'i' 'i' i I l i-- 9 i ~ i-J a, - ~ l ' .J ~: ~ la! 1 ~ ~ ~ j I I I I I I I I - ,__ I - I '.J I I I 35*iiss* 1 cs5*1~1r38") 95*/208.09" 125'~273.80" 1 1 N2D i 2E / 3 I I 2cr 4 *81 '1 55'/120.47" 77 /168.66" 1 lO" / 29o.94* 50'/109.52" VSC1-55 VSC1-77 >JR* 1 Y i i I I N1A I 1-- 9 1-- I - 155*/.lo5.22:), 15)410.93"1 245*/J3s.s5* N2F -..,N2G N2H i 200 / 488.08" i 197 /431.51" 230" /503.79" VSC1-197 N8B h y i ,__ i !a!, i '(5 i-N1B 275* /6i2.36" 305* / ~68.07" ' N2J I N2K ) I 290* /635.22* I 317 /694.35" VSC1-317
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 28 of 42 RPV-VSC1-55 (Contd) Examination Summary: This weld was examined from the inside surface using AIRIS-21 and Dynaray examination equipment.
- Limited examination due to proximity of the jet pump baffle ptate and N-8A nozzle.
Examination Angles for each probe included: PA60°-80°L, PA40°-50°S, PA30°-60°L, & PA0°l. Examination coverage =
- 83. 73%
Indication Summary: No recordable indications. Limitation Summary: Limited examination due to proximity of the jet pump baffle plate and N-Examination coverage = 8Anozzle. 83.73%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 29 of 42 RPV-VSC1-197 ~ 77/168.66° I 197/431.51* I I 317/694.36° I Weld C/L 524.50°11---~_....,. _______ VSCJ ____ - _77 _______________ _ vsc 3... -- 1_97 ________ vsc_ J-.. 3_1_1 __.._ __ -4 CW-CJC4 I~ 2<r /~3.e1* w /~ti,-42* 1so-/J.2:*56° 2 ~/438.08° 240" /525.69" 330' /722.83° ~C N~ J.. I ~.. :::====::::-:;::;,===:;;_;= _===::========::- *::====.======tG;;*:::===========:::11 I vs10.95* 45"/98.57'~ N11A 1 y I 185"/405.22 N5B I 65"/361.41" N9 I J..
- =========*:;;~;*=
.============--.. 11 1*:::====.===1::==t_;;:::=======1 225"/492.84" N11B I 215"/470.93" 245°/536.65° 275" /602.36" 35"/76.66° 65°/142.38° ~ '-.95°/208.09° Weld C/L 391.50° ___.._.. _______ _ '- -- R-,.+--R----r--------R-"..._-ff--+----+-- -+,,1- ---Cl---+-+--+1---...._.....-____ _ cw-c 2c 3 ~ It ;\__ 22"/48.19. "-1"-s i\_ 141"/308.84. 261"/571.69.__ V i\_323"/707.50" u VSC2-22 VSC2-141 VSC2-261 VSC2-323 ,JUL .., J IL - r:::J ~ -,J iL ,JUL --p-;; -,Jun1 .... L~~11~~,J*~L..q-rj ~...,.J IL ,JUL - p I.so*
- c: *
,!J ~ L ~ L U U !J U L ~. L ~ L U li U [ - - 1 I'.... ~ - .... ::: ~ ~ ~ - - - ,_ ~- - a:_ f"' ia:= =:,, I c:::: =:,, ia:= =i:> Weld C~!c~c~*--_--1-,_--_--+,..--+-r--i_--+_--I-_---~-,"'-~---------------+
- _:!I~:* -:! J: _*; J: -~: [~ -~;,$1=>>* \) J: _* :; J: )~ ~~ ~
I I I I I o* r I I I i i i i i i~ i i i we1dC/L125.so*~* - - i- ? - i-- - i- - i-NIA - i- - i-Y- i- - i CW-UICI I I I _I . ~ t _I _I s*110.9s* 35*116.66" 1
- 55*1142.38*
- 95*/208.09" 125*1213.eo*
155*/405.22*)* 15*1410.93* 245"/536.65" 215*1602.36" 305*/668.01*
- N2A N2B
- l.:
N2C ) N20 1' N2E N2F -......._w2c N2H N2J N2K ) ...,.....-- i i 1200 /488.08° I i 20" / 43-51 " i 55"/120.47" 77 /168.66" l lO" 1290*94* 197 /431.51
- 230' /503.79" 290" / 535*22* 317 /694.35" 50"/I09.52* VSC1-55 VSC1-77 VSCl-197 N8B VSC1-317 r)
J :=, I<= ~.~ ~ ~ 335"/~33.78" ' 0 i i-NIB N/14
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 30 of 42 RPV-VSC1-197 (Contd) Examination Summary: This weld was examined from the inside surface using AlRIS-21 and Dynaray examination equipment. Limited examination due to Core Shroud ti~own bracket and proximity of the jet pump beffle plate. Examination Angles for each probe included: PA60° -80°L, PM011 -5011S, PA30° ~0°L, & PA0°L. Examination coverage= 38.20% Indication Summary: Non-re1evant mid-wall plate segregates were noted in examination I0.S. Limitation Summary: Limited examination due to Core Shroud tie-down bracket and proximity of the jet pump baffle plate. Examination coverage = 38.20%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 31 of 42 RPV-VSC2-22 \ m,~u-I 197/431.51" I I 317/694.36" I Weld C/L 524.50"11.. 1_ \ ___________ V$C 3_-_7_7 _ _..__ _____________ _ vsc __ 3-_1_9_7 __________._ _______ vsc_3-___ 31_7 __.._ __ ~ CW--<:3C4 ~ 20-1~3.8.. 1
- w 1~£*42*
,so-{lt2t55* 2 0-/438.08" I 240-G~~5.69" ~g22.83"
- =========~::::~===:::::==========- *::==========:::i1c;~;*============:::11
~r::::ji==:ll~============-=:: :===t-45"/98.57" NIIA 1 y I 185'/405.22 N58 165'/361.41" N9 I J..
- =========~c::::~*.=============:::u r*:::====.===:==:::ic;_;=======:::::
225'/492.84" N118 I 215'/470.93" 245'/536.65" 275'/602.36" 35'/76.66" 65'/142.38" 95'/208.09" Weld C/L 391.50" t--ff-¥'r-fl--+-----+-~,.+-- --iH + ff-----r---------fl.... l---i,-+----+---t,,t--+--ff--+1-flt----r--------i CW--<:2C3 I\_ V I\_ 1.50"
- \... ~:~21t
~~r4* 261/41~2ir ~{!~~350* ,JUL J ,JI IL - Pj ~ -,J ~ ,JUL..p. -,J,;L..I.U~Llltll:'11J-,.1-fi'1~L..q-Pj ~,.,J ~ ,JUL - p i:: ~ ~ ~ ~ ~ ~ ~ ~ ~ i ! ~ ~ ~ ~ ~ ~ ~ I~ ~ ~ I ~~ ~- ~- ~- ~ ~ ~- J 11 a:_ ri>I 10:;:: :i:,, I c: ;:::a 1a:: :1=> Weld C~!cs:'ct H--++-+--lll'-+--sr+-++-t--,t-1-+-++--+r-+-+-t-++-+-lltl-l...++-t+-+~--l------+-t+--++-rttt-+-11-t--++-+--+-t-+-++-+--.+-+-t-++--+-- t-++-++-+r--------t-1 , cl IL.~ ' i Weld C/L 125.50" ~ --- i.-. ' i i--- i.-. I I y,..._ i ----- ) ( c' ~ ~I I I I I - i --- - i-CW-1..HCI ~ 5'/10.95" N2A 35'/~6.66" i '65'/1~2.38") 95*/d08.09" 125'fi73.eo* N2B , ~ N2C N20 1, N2E _.,,.,. I I 20-/43.81" 55'/120.47" 77/168.66" 110-/290.94" I VSCl-55 VSCl-77 50" /109.52" 155'/~39.51" 0 NIA L,., L,.., L I I I I I I --- i-i--- y - i ~*.~ h ' i --- - i -.~ c - ~ 335'/~33.78" I I i- 0 NIB 155*Ao5.22*)' 15)410.93"1 245'/~36.65" N2F '"-.'N2C N2H I 200-/488.08" i 275' 1sb2.36" 305' /J68.07" ' N2J I N2K ) 197 /431.51
- 230" /503.79" VSCl-197 N88 I
I 290-/635.22" 317 /!94.35" VSCl-317 J.. - ~
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 32 of 42 RPV-VSC2-22 (Contd) !Examination Summary: 1This weld 'W8S examined from the inside surface using AIRIS-21 and Dynaray examination equipmenl Examination Angles for each probe included: PA60D-8QDL, PA40"'-50°S, PA30*-00°L, & PA0°L. Examination coverage= 57.07% Indication Summary: Non--relevant mid-wall plate segregates were noted in examination ID-9 and ID-10. Limitation Summary: 1Examination limited due lo core shroud tie-<lown bracket and jet pump Examination coverage = bracket. 57.07%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 33 of 42 RPV-VSC3-77 ~ '"'~"- I 197/431.51. I I 317/694.36. I weld c/L 524,so*1..... ____ ~---....a..,_ __ vsc 3_-_77 _______________ _ vsc 3-_1_97 __ vsc _ J-_3_1_1 __.._ __ -1 CW-C3C4
- ~
20' /43.81" 60' /131. 150' /328.56. I N<IA N4B 2 O' /438.08" I 240' /525.69" 330' /722.83" ~C N~ I 1t::====c:_,=.=1====::::1 *c==.==::::CCj*c:=====ll11 45'/98.57" N11A 1 y I 185'/405.22 N5B 165'/361.41" N9 I 1c===:::::i*C:~:)*= .=====::::JJ11 1t::==.=11=::::C_::)::====1 225"/492.84" N118 1 215'/470.93. 245'/536.65. 275' /602.36. 35'/76.66" 65'/142.38" 95'/208.09" Weld C/L 391.so* I--R-...,_ff--+----+--11-t-----l-R-,,+-,f!----r--------R-"..._-fl--+----+--+-i----t.,_ff-t+-fl----....._..,... ____ ----I CW-C2C3 I\_ V I\_ u ~~r4* 261/4~~2ir- ~{~~t}so* ~ 2 2' /48.19. VSC2-22 -p.....J1n1-UL... ~--IJlJ[~:..,.J.,.;*11ilLi--<l-Pj ~ -..J ~ '- " JUL - p l IL - Pj ~ -
- JUL '-
JI ..J IL
- -,. " JUL i.so*
~~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~- I ~ c: ~:,, i:= ~ 1j ~ ~ ~ ~ ~ ~ 1- -rel ~* I l= l=D 10:~ =l:D Weld C~!c~ct H-++--+-llll-l-++-ll+-+----++-+-1-+- -+-++--++-+-- 1-++--1+-t--L------+-++--++-+w-1-++-1+-+---+-++-++-+_.,-+-++--++-+- +-++-++-+....._ ____ _ II -, Weld C/L 125.SO CW-UIC1. 'r i i .J ~ 5'/1~.95" N2A IL.~ "' l J., ~= J = ) '
- let f-f-
f-
- ~
~ :~ ~ ~ ""' ~ ""'
- a>
=* '"( I i '"( I I i- ? - i - - i i-35'/i6.66"
- , -~5'/1~2.38" '
95'/~08.09" N28 , l.: N2C ) N20 125*A73.eo* __..... i i 20'/43*81
- i__.....
55"/120,47* 77/168.66. 50' /l09.52* VSCl-55 VSCl-77 i N2E 110' /290.94" 155'/~39.51" 0 N1A L '= L .,,i L -~= i J = * ) ' '= J = f-f- f-f-
- ~
~ ~ ~!.~ ""' -~ ~.~ ~ ~ Ir", 335'/~33.78" '"( '"( '"( '-( 'r 0 i i i i I i-i- ? i i i-N18 155*/.:05.22*)* 15)410.93"1 245'/J36.65" N2F
- ,N2G N2H i 200' / 488.08" i 197 /431.51" 230' /503.79" VSCl-197 N88
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 34 of 42 RPV-VSC3-77 (Contd) Examination Summary: This weld was examined from the Inside surface using AIRIS-21 and Dynaray examination equipment. Examination Angles for each probe included: PA60°-80°L, PA40"-50"S, PA30"-60"L, & PAO"L. ID Exam limited due to proximity of core spray sparger. Examination coverage= 75.21% Indication Summary: Minor outside surface Irregularities were noted on Exam 10-19-1. Three indications were sized and evaluated in accordance with the acceptance criteria of Section XI, 2007 Edition with 2008 Addenda (07E/08A}. They were found to be acceplable. i Indication 2a a t alt s t (In) Location Allowable alt% 110-17-1-1 0.10 0.05 1.35 0.04 2.80 6.10 Subsurface 2.2 0.8% 11D-17-2-1 0.20 0.10 1.35 0.07 2.60 6.10 Subsurface 2.3 1.6%
- 1D-18--1-1 0.30 0.15 1.35 0.11 2.30 6.10 Subsurface 2.6 2.5%
Limitation Summary: ID Exam limited due to proximity of core spray sparger. Examination coverage= 75.21%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 35 of 42 RPV-VSC3-197 Weld C/L 524.50 11--~--------....:::--..7~,,....1_6!_7_~6_*_.... IL-____________ ++-_1_~ _1.,3*-.. 3,_~_~_1* ___ 1 _____..... IL-_______ 3_~_1_!T9_;;_3;_. _ _....I __ --I ~~X4 ~ 20'/~3.8,. w1~v:42* I'-----.. 150'/J.2:*55* 2 ~/438.08. 240',525.69. 3~/J22.83 * .-L I ~ ..L 1c .-L ~.. ~~~~~~ - :~t~==:::i-~~~~~~~~-~~~~~~~ .. ~::-~~=~~=~~=~~~~c~r ... *~~=~~=~~======::::o.. :::===~==:;==~_;;=======1 I ~ 5' {10,95* 45'/98.57" 2 t/5,, N11A B l N9 225"/492.IW N11B 1 215'/470.93° 245'/536.65" 275' /602.36° 35'/76.66° 65'/142.38" 95'/208.09° Weld C/L 391.50" 1---ff-..... -R--+----- --- - -+---*+-+- ff----...----------R--""-l'l------- -hl-----ff--+,...-!'ii--------------1 ~~ 2 C 3 ~ It ~ 22'/*e.!9" ~ 141'/308.84" 261'/571.69"- v l\_323'/707.50" u VSC2-22 VSC2-141 VSC2-261 VSC2-323 ~UL JJ ) IL - rj ~ -,J iL ~UL..~ -,J~nl .... L~~11~~,Jiif'1 j\--L.q-rj ~,. J ~ ~UL - p 1.50"
- c:
- 1,,!J IJ L
IJ, L IJ li U !J U L U, L IJ li U li U I: -a:_. ( : ~ ~ ~ - .... ~- - J J - ia::= =:,, I -== =:,, 1a:= =~ Weld C~!cs:'c~*-------------+r---------+~-,-------------------------------------!I ' i Weld C/L 125.50° ll - ~-UICI Ef$ 5'/10.95° N2A L. l ( .J I i - i- ? I i ~ i ~ ' i - i~ 35'/i6.66° '1
- 65'/1~2.38°
- 95'/~08.09° N2B
- t._:
N2C ) N20 ' i - i- _,,, i i 20-/43-51
- 55'/120.47° 77/168.66° I
VSC1-55 VSC1-77 125*/ineo* i 'N2E 110' /290.94" 50' /109.52° N/14 NIA
- ' >=
L.. JL ~ ~! ~ I I i i i - i i-Y- i-155*1.:05.22*)* 15*}410.93* 245'/~36.65" N2F
- ,'N2C N2H I 200; 488.08" 197/431.51" 230'/503.79° VSC1-197 N8B
~.~ ' i - i ' i i- '(5 215*;sb2.35* 305*/~68.01*
- N2J N2K
) I 290' / 535*22" 317 /!94.35° VSC1-317 NIB L
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 36 of 42 RPV-VSC3-197 (Contd) Examination Summary: This weld was examined from the inside surface using AIRIS-21 and Oynaray examination equipment. Examination Angles for each probe included: PA60° -80°l, PM0°-50"S, PA30° -60"l, & PAO"l. The examination from the ID was limited due to the proximity of the Core Spray Spargetl. Examination coverage from the ID= 73.59% Indication Sumrnary: Non-19levant mid-wall plate segregates were noted on Exam ID-20, 10-21, and 10-22 and minor outside surface irregularities we.-e noted on Exam 10-22. One indication was sized and evaluated fn accordance with the acceptence criteria of Section XI, 2007 Edition with 2008 Addenda 07E/08A. It was found to be a table. Indication 2a a t alt Location Allowable alt% 10-22-1 0.20 0.10 1.35 0.07 Subsurface 2.3 1.7% Limitation Summary: ID Exam limited due to proximity of core spray sparger. Examination coverage from ID= 73.59%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 37 of 42 RPV-VSC3-317 Weld C/L 524.50 ll-~-----------:.::;:....:.:. 7_....JL ___________.=:jj::::1::"" 97="1~3*-~31:.:~:.:.~_1*_,,,b-l _______ lL _______ 3.:,~~/::;_;9:..ji:,.:3:_._....JI __ --I CW-C3C4 20' /43.81. I 60' 1~v:42* 150' it.2:*55* 2 ~/438.08" 240',525.uo 3~/ J22.83. 1c .J.. I .. :::=========~-;;~_===::;:========::- 1:====.======:::1~~}*============::::11 45'/98.57" N11A 1 y I 185'/405.22 N5B 165'/361.41
- N9 1:=========~G~~*.=============::::o.. :::====.===;==::::;;_;========1 225"/492.84.
N11B 1 215'/470.93. 245'/536.65. 275' /602.36. 35'/76.66. 65'/142.38" 95'/208.09. Weld C/L 391.50* 1---ff-..... -R--+----- --- - -+--*+-+- ff----...----------R--""-l'l------- -hl-----ff--+,...-!'ii-------------1 CW-C2C3 ~ It ~ 22'/ +e.19* ~ 141'/308.84. 261'/571.69"- v l\_323'/707.50* u VSC2-22 VSC2-141 VSC2-261 VSC2-323 ,JUL JJ ) IL - rj ~ -,J iL ,JUL.. ~ -,J~nl .... L~~11~~,Jiif'1 j\--L.q-rj ~,. J ~ ,JUL - p I.so*
- c:
- 1,,!J U
L U, L U li U !J U L U, L U li U li U I: -a:_. ( : ~ ~ ~ - ..... ~- - J J - ia::= =:,, I -== =:,, 1a:= =~ Weld C~!cs:'c~*-------------+r----------------+------------------------------ ~ -, ' i Weld C/L 125,50* ll - CW-UICI Ef $ 5*/10,95* N2A L. l ( I i - i- ? I i ~ i ~ ~ ~! ' i - i - 35'/ i6.66. '1
- 65'/1 ~2.35*
- 95'/~08.09.
N2B
- t._:
N2C ) N20 ~ .J -~: ' i i- ......... i i 20-/43-51
- 55*;120,47* 77/ 168.66.
I VSCl-55 VSCl - 77 125*/ineo* i 'N2E 110' /290,94* 50' /109.52. N/14 155'/139,51* 0 NIA L * ' >= L ' '= iL -~io= i L. r) ( >=
- ~
~ ~ ~! ~ ~ I I I I - i i- ? - i-155*1.:05.22*)* 15*}410.93* 245'/~36.65. N2F 1
- ,'N2C N2H I 200; 488.08*
197/431.51" 230'/503.79. VSCl-197 N8B -~ ~.~ ~ 335'/~33.78. ' 0 i I - i i-N1B 275'/sb2.36. 305'/~68.07.' N2J I N2K ) I I 290' / 535*22" 317 /!94,35* VSCl - 317 L - ~
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 38 of 42 RPV-VSC3-317 (Contd) Examination Summary: This weld was examined from the inside surface using AIRIS-21 and Dynaray examination equipment. Examination Angles for each probe included: PA60°-80°L, PA4O°-50°$, PA30°-60°L, & PA0°l. The examination from the ID was limited due to the proximity of the Core Spray Sparger. Examination coverage from the ID= 78.58% Indication Summary: Non-relevant mid-wall plate segregates were noted on Exam ID-23-1, ID-23-2, and ID-24.Minor outside surface irregularities were noted on ID-23-1, 1~23-2, 10-24, and ID-25. Limitation Summary: ID Exam limited due to proximity of core spray sparger. Examination coverage from ID= 78.58%
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 39 of 42 Coverage Plots for the Following Welds: RPV-VSC1-55 RPV-VSC1-197 RPV-VSC2-22 RPV-VSC3-77 RPV-VSC3-197 RPV-VSC3-317 Weld C/L 40° Incident Point PA22-006 Module Pivot Point 7.50" CW from Weld C/L 40° Incident Point t-----1i PA22-006 40° Incident Point PA22-006 Module Pivot Point 7.50" CCW from Weld C/L 40° Incident Point PA22-006 Shell #1: 55°,'. 197° Shell #2: 22°, Shell #3: 77°, 197°,317°
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 40 of 42 BMR-167-305 (Beltline Weld Repair Area at 167°, Elevation 307.0 inches) Interference location ,.j C/L 472.00" --- Weld C/L 524.50 CW-CJC4
- I
~ VSC3-77 I 2cr /43.81
- SU~
I ..L
===o I ~ S;(J0.95" 45'/98.57" N11A 1 35'/76.66" 65'/142.38" 95'/208.09" ' ~ II VSC:3-197 15cr /328.56" ~ 2 fcr/438.08 N48 I ..L 0:::: I 185'/405.22 N5B y 165'/361.41" N9 215'/* Weld C/L 391.50" Weld C/L 391.50" CW-C2C3 .'\... 22"/48.19" ~ ~"~-} j :J Jet Pump Riser Support elev JOJ.50 Weld C/L 258.50" Weld C/L 258.50 CW-C1C2 Weld C/L 125.50 CW-LHC1 VSC2-2.2 ~
- rot J -
Pj ~ -, ,J IL ,J JL ,JUL p~ ll~ ~ ~ g ~~ ~ ~pg p P>-~ IC =p, O:f= := ::0 I! .,J, L .J L.~ l =<~ ' ' t:
- ~I>=!"
~ :~ ~ ~ ~ :~ ~* ~ ~ h ~ h ~ h 'i' 'i' 'i' i 'i' i i i i i . i i-I' - i - i i -
- 11b.95*
35'/~6.66" '65'/1~2.38" ' 95' /~08.09" I 125' 273.80" N2A N2B ......-j ~ N2C ~ N20 1, I I 20'/43.81" 55'/120.47" 77/168.66" 110'/290.94" I VSC1-55 VSC1-77 5cr /109.52" ~2E NBA 155'/339.51 " I 0 N1A 4ll- ~~ I IC= ;=;::,, '" =-= t,, ~ ~ ~ Ir 'i' 'i i i i i 155* ~05.22* ' I 15' ~2F ) ~ 12ocr /488 197/431.51" VSC1-197
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 41 of 42 BMR-167-305 (Contd) CW/CCW Scan Up/Down Scan o.19 - 11=-s.13-j 40° INCIDENT POINT PA22-006 MODULE PIVOT POINT5.50"/318.82 40° INCIDENT POINT PA22-006 I>------< CENTER OF AIRIS DEVICE 313.32 POSITION 2 MODULE PIVOT POINT 5.50"/308.93 MODULE PIVOT POINT 5.50"/307.82 CENTER OF AIRIS DEVICE 303.43" POSITION 1 40° INCIDENT POINT PA22-006 MODULE PIVOT POINT 5.50"/297.93 40° INCIDENT POINT PA22-006 Repair C/L 308.38" Beltline Region Repair Weld: BMR-167-305 Increment: 369.67" to 396.67 Repair C/L 383,1 8" 40° Incident Point PA22-006 - Module Pivot Point 7.00" I 396.25" 40° Incident Point PA22-006 -Center of AIRIS Device 389.25" Position 2 Module Pivot Point 7.00"/ 384.11" Module Pivot Point 7.00"/ 382.25" L-----11 Center of AIRIS Device 377.11" Position 1 40° Incident Point PA22-006 - Module Pivot Point 7.00" I 370.11 40° Incident Point PA22-006 Beltline Region Repair Weld: BMR-167-305 Increment: 297.13" to 319.62
ATTACHMENT 2 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 1 Page 42 of 42 BMR-167-305 (Contd) Examination Summary: This repair area was examined from the inside surface using AIRIS-21 and Oynaray examination equipment. Examination Angles for each ID probe included: PA60°..00°L, PA40°-50"S, PA30"-60°l, & PA0"l. fxamination coverage;;::; 66.4% Indication Summary: No recordable indications. Limitation Summary: Examination limited due to Jet Pump Riser bracket. Examination coverage = 66.4%
ATTACHMENT 3 Quad Cities Generating Station 10 CFR 50.55a Relief Request I5R-26 Additional Details and Supporting Information Unit 2 Page 1 of 73
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 2 of 73 N2A NOZ (Recirculation nozzle to RPV weld) '~ Quad Cities Unit-2 N2 - Recirc Inlet Nozzle 6Cr S6 Exam Volume
- 30.9 Sq. In.
ro-S4 Exam Volume. 4.2 Sq. In. Inner 1596T SS Exam Volurne
- 4.2 Sq. In.
60* S6 Exom Volume Achieved
- 1S.4 Sq. ln.
6(t S4 Exam Volume Achieved
- 4.2 Sq. In.
IMer 1S96TS5 Exom Voll#Tle Achieved
- 4.2 Sq. In.
Examination volume i.o.w. Code Cose N-613* 1 Circumferential exominotion of the outer 8596T is not required i.o.w. the 2007 Edition w/ 2008 Addeodo. NZ Nozzle to Shell Scon Limits at Top Dead Center 13.7" 60"T Quad Cities Unit-2 N2 - Recirc Inlet Nozzle NZ Nozzle to Shell Scan Limits at 90° / 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 3 of 73 N2A NOZ (Contd) Weld Length = Exam Volume = 60° T-Scan {S6) 60° T-Scan (54) IRS P-Scan (S51 60° T-Scan (56) 60° T-Scan IS4) IRS P-Scan (S51 60° T-Scan IS6) 60° T-Scan (S4) IRS P-Scan {S5) 60° T-Scan {S6) 60° T-Scan {S4) IRS P-Scan (S5) 60° T-Scan {S6) 60° T-Scan (S4) IRS P-Scan (S5) 360. 35.1 A A A Quad Cities Unit 2, Q2R22, 2014 N2A CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 30.9 4.2 4.2 Area Scanned 15.4 4.2 4.2 Percent of Area Scanned 43.9% 12.0% luu.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coverage= Comments: A - Manual scanning was restricted due to the nozzle configuration. Percent Scanned 21.9% 6.0% 50.0% 77.9% IIA!v. O 9/20/13 Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda. 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addendc Note - Rounding methods may affect calculated values. 56 - Suoolement 6, S4 - Supplement 4. S5 Supplement - 5. Weld lenqth in deqrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 4 of 73 N2A NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component no recordable indications were observed. The inner 15% examination volume as defined by 10CFRS0 was performed per procedure GEH-UT-311, Ver. 19, utilizing search units validated by modeling. Scanning was restricted due to nozzle configuration. 77.9% of the code required volume was achieved. This examination meets the requirements of ASME Section XI, 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 5 of 73 N2B NOZ (Recirculation nozzle to RPV weld) o* <t Quad Cities Unit-2 N2 Recirc Inlet S6 NS exam volume = 9.2 Sq. In. S6 FV exam volume= 20.2 Sq. In. 54 exam volume = 4.3 Sq. In. Inner 15%T IRS exam vofl.me = 4.3 Sq. In. 60°T S6 NS coverage achieved = 0.0 Sq. In. 60°T S6 FV coverage achieved - 16.1 Sq. In. 60°T S4 coverage ochieved = 4.3 Sq. In. Inner 15%T IRS coverage ochieved = 4.3 Sq. In. 60°T Neer Surface Seen not required due to nozzle ODBR configurotion. 2B Cross Sectional Coverage @ 0° Az. 13.6" 60"T I \ O" <t. 1ss* 60'1 N2B Cross Sectional Coverage@ 90° Az.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 6 of 73 N2B NOZ (Contd) Weld Length = Exam Volume = 60° T-Scon (S6 NSI 60° T-Scon (S6 FV) 60° T-Scon (S41 IRS P-Scon (S51 60° T-Scon (S6 NSI 60° T-Scon (S6 FVl 60° T-Scon (S4l IRS P-Scon (SSI 60° T-Scon IS6 NS) 60° T-Scon (S6 FVI 60° T-Scon (S4l IRS P-Scon ISSI 60° T-Scon IS6 NS) 60° T-Scon (S6 FVI 60° T-Scon (S4l IRS P-Scon (SSI Comments: Code Cose N-613-2 applies. 360. 33.7 A A A A Quad Cities Unit-2 N2B NOZ (Recirc Inlet) CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Required Exam Area Sq. in. Area Examined Percent of Area Weld Length Examined Examined 9.2 0.0 0.0% 360 20.2 16.1 47.8% 360 4.3 4.3 12.8% 360 4.3 4.3 100.0% 360 % Total Composite Coverage= A - Manual scanning was restricted due to the nozzle configuration. Percent Examined 0.0% 23.9% 6.4% 50.0% 80.3% ~ -2/22/201! Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - RoundinQ methods may affect colculoted values. S4/5/6 - Supplement 4, 5 or 6. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 7 of 73 N2B NOZ (Contd) Comments: Ultrasonic examination results were acceptable to the requirements of ASME B&PV Code Section XI, 2007 Edition with the 2008 Addenda, as modified by the POI program description and the Federal Register. Part II, Nuclear Regulatory Commission, 10 CFR Port 50 for Category 8-0 Reactor Pressure Vessel (RPVI Assembly Welds. Manual radial scans were performed in accordance with procedure GEH-UT-300 V. 12 using 60° RL search units. Manual Inner 15%T circumferential scans were performed in accordance with GEH-UT-311 V. 19 using model validated search unit angles. Manual scanning was performed from the vessel OD surface and was restricted due to the nozzle configuration. Near surface examinations were not performed due to the ODBR configuration. No recordable indications were detected. Achieved coverage = 80.3%.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 8 of 73 N2D NOZ (Recirculation nozzle to RPV weld) Quad Cities Unit-2 N2 - Recirc Inlet Nozzle 60- S6 Exam Volume - 30.9 Sq. ln. 60* $4 Exam Volume a 4.2 Sq. In. Inner 1596T SS Exam Volume = 4.2 Sq. In. 60° S6 Exam Volume Achieved = 15.4 Sq. In. 60° S4 Exam Volume Achieved :c 4.2 Sq. In. Inner 1596T SS Exam Volume Achieved= 4.2 Sq. In. Examination volume i.o.w. Code case N*613*1 Circumferential examination of the outer 85%T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. NZ Nozzle to Shell Scan Limits at Top Dead Center 13.7" 60'T Quad Cities U nit-2 N2 - Recirc Inlet Nozzle NZ Nozzle to Shell Scon Limits ot 90° / 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 9 of 73 N2D NOZ (Contd) Weld Length = Exam Volume = 60° T-Scan !S6) 60° T-Scan (S4) IRS P-Scan (SSJ 60° T-Scan (S6l 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 360. 35.1 A A A Quad Cities Unit 2, Q2R22, 2014 N20 CODE CROSS-SECTIONAL AREA Required Exam Area Sq. In. 30.9 4.2 4.2 Area Scanned 15.4 4.2 4.2 Percent of Area Scanned 43.9% 12.096 100.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coveroge = Comments: A - Manual UT scanning was restricted due to the nozzle configuration. Percent Scanned 21.9% 6.0% 50.Uo/o 77.996 Rev. 0 9/20/13 Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S6 - Suoolement 6. S4 - Suoolement 4, SS Supplement - 5. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 10 of 73 N2D NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications were observed. The inner 15% examination volume as defined by 10CFRS0 was performed per procedure GEH-UT-311, Ver. 19, utilizing search units validated by modeling. Scanning was restricted due to nozzle configuration. 77.9% of the code required volume was achieved. This examination meets the requirements of ASME Section XI. 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 11 of 73 N2E NOZ (Recirculation nozzle to RPV weld) Quad Cities Unit-2 N2 - Recirc Inlet Nozzle 60" S6 Exom Volume
- 30.9 Sq. In.
GO* S4 Exam Volume = 4.2 Sq. In. Inner 15%T S5 Exam Volume = 4.2 Sq. In. GQ* S6 Exam Volume Achieved = 15.4 Sq. In. 60° S4 Exam Volume Achieved -= 4.2 Sq. In. Inner 15%T SS E)(om Volume Achieved= 4.2 Sq. In. Examination volume i.a.w. Code Case N-613-1 Circumferential examination of the outer 85%T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. N2 Nozzle to Shell Scan Limits at Top Dead Center 13.7" 60"T 3.4" 60"T Quad Cities Unit-2 N2 - Recirc Inlet Nozzle N2 Nozzle to Shell Scan Limits at 90° / 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 12 of 73 N2E NOZ (Contd) Weld Length = 360. Exam Volume= 35.1 60° T-Scan (S6) A 60° T-Scan (S4) A IRS P-Scan (SSJ A 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) Quad Cities Unit 2, Q2R22, 2014 N2E CODE CROSS-SECTIONAL AREA Percent Required Exam Area of Area Area Sq. in. Scanned Scanned 30.9 15.4 43.9% 4.2 4.2 12.0% 4.2 4.2 100.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Com site Covera e = po g Comments: A - Manual UT scanning was restricted due to nozzle configuration. Percent Scanned 21.9% 6.0% OU.U"/o 77.9%
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 13 of 73 N2E NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications were observed. The inner 15% examination volume as defined by 10CFRS0 was performed per procedure GEH-UT-311, Ver. 19. utilizing search units validated by modeling. Scanning was restricted due to nozzle configuration. 77.9% of the code required volume was achieved. This examination meets the requirements of ASME Section XI. 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 14 of 73 N3A NOZ (Main steam nozzle to RPV weld) o* Ct. Quad Cities Unit-2 N3 Main Steam 56 NS exam volume= 10.7 Sq. In. 56 FV exam volume= 21.9 Sq. In. 54 exom volume= 4.7 Sq. In. Inner 15%T IRS exam volume= 4.7 Sq. In. 60°T 56 NS coverage achieved = o.o Sq. In. 60°T S6 FV coverage achieved = 16.0 Sq. In. 60°T S4 coverage achieved = 4. 7 Sq. In. Inner 15%T IRS coverage achieved= 4.7 Sq. In. 60-T Near Surface Scan is not required due to nozzle ODBR configuration. 1*6* 60"1 N3A Cross Sectional Coverage @ 0° A2. o* <t. N3A Cross Sectional Coverage @ 90° Az. IS.8" 60"T
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 15 of 73 N3A NOZ (Contd) Weld Length = Exam Volume= 60° T-Scon IS6 NS) 60° T-Scon (S6 FV) 60° T-Scon (S4) IRS P-Scon {SSJ 60° T-Scon (S6 NS) 60° T-Scon (S6 FVJ 60° T-Scon (S4) IRS P-Scon ISSI 60° T-Scon (S6 NS) 60° T-Scon (S6 FV) 60° T-Scon (S4) IRS P-Scon (SS) 60° T-Scon (S6 NS) 60° T-Scon (S6 FV) 60° T-Scon (S4) IRS P-Scon ISSI Comments: Code Cose N-613-2 applies. 360. 37.3 A A A A Quad Cities Unit-2 N3A NOZ Main Steam) CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Required Exam Area Sq. in. Area Examined Percent of Area Weld Length Examined Examined 10.7 0.0 0.0% 360 21.9 16.0 42.9% 360 4.7 4.7 12.6% 360 4.7 4.7 100.0% 360 % Total Composite Coverage= A - Manual scanning was restricted due to the nozzle configuration. Percent Examined 0.0% 21.4% 6.3% 50.0% 77.7% Rov. lll 21ZOII Note - This coverage calculation is valid for ASME Section XI. 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods moy affect calculated values. S4/S/6 - Supplement 4, 5 or 6. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 16 of 73 N3A NOZ (Contd) Comments: Ultrasonic examination results were acceptable to the requirements of ASME B&PV Code Section XI, 2007 Edition with the 2008 Addenda, as modified by the POI program description and the Federal Register, Part II, Nuclear Regulatory Commission. 10 CFR Part 50 for Category B-D Reactor Pressure Vessel (RPVI Assembly Welds. Manual radial scans were performed in accordance with procedure GEH-UT-300 V. 12 using 60° RL search units. Manual Inner 15%T circumferential scans were performed in accordance with GEH-UT-311 V. 19 using model validated search unit angles. Manual scanning was performed from the vessel OD surface and was restricted due to the nozzle configuration. Near surface examinations were not performed due to the ODBR configuration. No recordable indications were detected. Achieved coverage= 77.7%.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 17 of 73 N4A NOZ (Feedwater nozzle to RPV weld) N4 - Feedwater Nozzle 60° 56 El<om Volume
- 31.2 Sq. In.
60'" S4 Exam Volume.. 4.0 Sq. In. Inner 1596T SS Exam Volume = 4.0 Sq. In. 60* S6 Exam Volume Achieved... 13.2 Sq. In. 60* S4 Exam Volume Achieved.. 4.0 Sq. In. Inner 1596T SS Exam Volume Achieved. 4.0 Sq. In. Examination volume i.o.w. Code Cose N-613-1 Circumferential examination of the outer 8596T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. N4 Nozzle to Shell Scan Limits at Top Dead Center 13.7" 60°T Quad Cities Unit-2 N4 - Feedwater Nozzle N4 Nozzle to Shell Scan Limits at 90° I 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 18 of 73 N4A NOZ (Contd) Weld Length = Exam Volume = 60° T-Scon (S6) 60°T-Scon(S4) IKS P-Scon IS!>) 60° T-Scon(S6l 60° T-Scon (S4) IRS P-Scon (SS) 60° T-Scon (S6J 60°T-Scon (S4) IRS P-Scon (SS) 60° T-Scon (S6l 60° T-Scon (S4) IRS P-Scon (SS) 60° T-Scon (S6J 60° T-Scon (S41 IRS P-Scon (SS) 360. 35.2 A A A Quad Cities Unit 2, Q2R22, 2014 N4A CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 31.2 4.0 4.0 Area Scanned 13.2 4.0 4.0 Percent of Area Scanned 37.5% 11.4% 100.U'M> TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coverage= Comments: A - Manual UT scanning was restricted due to nozzle configuration. Percent Scanned 18.tf7o 5.7%
- >U.Uo/o 74.4%
Rf<I. 0 9/20/ll Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda. 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S6 - Supplement 6. S4 - Supplement 4, SS Suoolement - 5. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 19 of 73 N4A NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications were observed. The inner 15% examination volume as defined by 10CFRSO was performed per procedure GEH-UT-311. Ver.19 utilizing search units validated by modeling. 74.4% of the code required volume was achieved. This examination meets the requirements of ASME Section XI. 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 20 of 73 N4B NOZ (Feedwater nozzle to RPV weld) N4 - Feedwater Nozzle 60° S6 Exam Volume~ 31.2 Sq. In 60° S4 Exam Volume = 4.0 Sq. In. Inner 1596T S5 Exam volume
- 4.0 Sq. In.
60- S6 Exam Volume Achieved = 13.2 Sq. In. 50* S4 E1<om Volume Achieved
- 4.0 Sq. In.
Inner 15961 S5 Exam Volume Achieved
- 4.0 Sq. In.
Examination volume i.o.w. Code Cose N-613*1 Circumferentiol examination of the outer 8596T is not required i.o.w. the 2007 Edition w/ 2008 Addenda. N4 Nozzle to Shell Scan Limits at Top Dead Center 13.7" 60"1 Quad Cities Unit-2 N4 - Feedwater Nozzle N4 Nozzle to Shell Scan Limits at 90° / 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 21 of 73 N4B NOZ (Contd) Weld Length = Exam Volume = 60° T-5can (56) 60° T-5can (54) IRS P-5can (SSJ 60° T-5can (56) 60° T-5can (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-5can (54) IRS P-Scan (SSI 60° T-5can (S6) 60° T-Scan (54) IRS P-5can (SS) 60° T-Scan (56) 60° T-5can (54) IRS P-Scan (SS) 360. 35.2 A A A Quad Cities Unit 2, Q2R22, 2014 N4B CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 31.2 4.0 4.0 Area Scanned 13.2 4.0 4.0 Percent of Area Scanned 37.5% 11.4% 100.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coverage= Comments: A - Manual UT scanning was restricted due to nozle cont1guration. Percent Scanned 18.8% 5.7% OU.Uo/o 74.4% Rev. 0 9/20/13 Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S6 - Supplement 6, S4 - Supplement 4, SS Supplement - 5. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 22 of 73 N4B NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications were observed. The inner 15% examination volume as defined by 10CFR50 was performed per procedure GEH-UT-311, Ver. 19 utilizing search units validated by modeling. 74.4% of the code required volume was achieved. This examination meets the requirements of ASME Section XI, 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 23 of 73 N4C NOZ (Feedwater nozzle to RPV weld) I I / I 4.8" 60"! N4 - Feedwater Nozzle 60' S6 Exom Volume - 31.2 Sq. In 60' 54 Exom Volume= 4.0 Sq. In. Inner 1596T S5 Exam Volume -= 4.0 Sq. In. 60° S6 Exam Volume Achieved= 13.2 Sq. In. 60° 54 Exam Volume Achieved= 4.0 Sq. In. Inner 1596T S5 Exom Volume Achieved
- 4.0 Sq. In Examination 110lume i.o.w. Code Cose N-613-1 Circumferential examination of the outer 8596 T is not required i.o.w. the 2007 Edition w/ 2008 Addenda.
13.7" 60"! N4 Nozzle to Shell Scan Limits at Top Dead Center Quad Cities Unit-2 N4 - Feedwater Nozzle N4 Nozzle to Shell Scan Limits at 90° / 270
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 24 of 73 N4C NOZ (Contd) Weld Length = Exam Volume= 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6) 60° T-Scan (S4) IRS P-Scan (SS) 360. 35.2 A A A Quad Cities Unit 2, Q2R22, 2014 N4C CODE CROSS-SECTIONAL AREA Required Exam Area Sa. in. 31.2 4.0 4.0 Area Scanned 13.2 4.0 4.0 Percent of Area Scanned 37.5% 11.4% 100.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coverage= Comments: A - Manual UT scanning was restricted due to nozzle configuration. Percent Scanned 18.8% 5.7% bU.Uo/o 74.4% Rov. 0 9/20/13 Note - This coverage calculation is valid for ASME Section XI. 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Rounding methods may affect calculated values. S6 - Supplement 6, S4 - Supplement 4, SS Supplement - 5. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 25 of 73 N4C NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications were observed. The inner 15% examination volume as defined by 10CFRSO was performed per procedure GEH-UT-311, Ver. 19 utilizing search units validated by modeling. Scanning was restricted due to nozzle configuration. 74.4% of the code required volume was achieved. This examination meets the requirements of ASME Section XI, 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 26 of 73 N4D-NOZ (Feedwater nozzle to RPV weld) N4 - Feedwater Nozzle 60" S6 Exam Volume
- 31.2 Sq. In.
60° S4 Exom Volume= 4.0 Sq. In. Inner 1596T 55 Exam Volume= 4.0 Sq. In. 6o: S6 Exam Volume Achieved. 13.2 Sq. In. 60 S4 Exam Volume Achieved= 4 o Sq In Inner 1596T 55 Exom Volume Ach~ed ** 4_0 Sq. In. ~ominotion volume i.o.w. Code Cose N-Gl3-l ~ircumferentiol examination of the outer 8596 T ,snot required i.a.w. the 2007 Edition w/ 2008 Addenda. N4 Nozzle to Shell Scan Limits ot Top Dead Center 13.7" 60"1' Quad Cities Unit-2 N4 - Feedwater Nozzle N4 Nozzle to Shell Scan Limits at go*/ Z?O 15.1" 60"1'
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 27 of 73 N4D-NOZ (Contd) Weld Length = Exam Volume = 60° T-Scan (S6l 60° T-Scan (S4) IRS P-Scan !SSJ 60° T-Scan (S6l 60° T-Scan (S4l IRS P-Scan (SS) 60° T-Scan (S6l 60° T-Scan (S4) IRS P-Scan (SS) 60° T-Scan (S6l 60° T-Scan (S4l IRS P-Scan (SS) 60° T-Scan (S6l 60° T-Scan (S4l IRS P-Scan (SS) 360. 35.2 A A A Quad Cities Unit 2, Q2R22, 2014 N4D CODE CROSS-SECTIONAL AREA Required Exam Area Sa. in. 31.2 4.0 4.0 Area Scanned 13.2 4.0 4.0 Percent of Area Scanned 37.5% 11.4% 100.0% TOTAL CODE COVERAGE Length Scanned 360 360 360 % Total Composite Coverage= Comments: A - Manual UT scanning was restricted due to nozzle configuration. Percent Scanned 18.8% 5.7% OU.0"/o 74.4% Rev. 0 9/20/IJ Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Note - Roundinq methods may affect calculated values. S6 - Supplement 6, S4 - Supplement 4, SS Supplement - 5. Weld lenqth in deqrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 28 of 73 N4D-NOZ (Contd) Examination Results: During the manual ultrasonic examination of the above referenced component. no recordable indications v.,,ere observed. The inner 15% examination volume as defined by 10CFRS0 was performed per procedure GEH-UT-311. Ver. 19 utilizing search units validated by modeling. Scanning was restricted due to nozzle configuration. 74.4% of the code required volume was achieved. This examination meets the requirements of ASME Section XI, 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 29 of 73 N5A-NOZ (Core spray nozzle to shell weld) / I I Quad Cities Unit-2 N5 - Core Spray 60' NS Exam Volume= 17.9 Sq. In. 60' FV S6 Exam Volume = 19.8 Sq. In. 60" FV S4 / 15% T IRS Exam Volume = 4.3 Sq. In. 60' NS T-Scan achieved = 0.6 Sq. In. 60' FV S6 T-Scan achieved = 17.0 Sq. In. 60' FV S4 T-Scan achieved = 4.3 Sq. In. Inner 15% T IRS-Scan achieved= 4.3 Sq. In. (By modeling.) 60'T I Manual scan coverage Quad Cities Unit-2 N5 - Core Spray 60' NS Exam Volume= 17.9 Sq. In. 60' FV S6 Exam Volume= 19.8 Sq. In. 60' FV S4 / 15% T IRS Exam Volume= 4.3 Sq. In. 60' NS T-Scan achieved= 0.6 Sq. In. 60' FV S6 T-Scan achieved = 12.1 Sq. In. 60' FV S4 T-Scan achieved= 0.0 Sq. In. Inner 15%T IRS-Scan achieved = 4.3 Sq. In. (By modeling.) Insulation support bracket limitation coverage
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 30 of 73 N5A-NOZ (Contd) Quad Cities Unit-2 N5A - Core Spray N5A Insulation support Bracket Limitation 145' Weld Length = Exam Volume = 50° T-Scan (S6 NS) 50° T-Scan (S6 FV) 60' T-Scan (S4) IRS P-Scan (54) 50° T-Scan (S6 NS) 60' T-Scan (S6 FV) 60' T-Scan (54) IRS P-Scan (S4) 50° T-Scan (S6 NS) 50° T-Scan (S6 FV) 60' T-Scan (S4) IRS P-Scan (S4) 50° T-Scan (S6 NS) so* T-Scan (S6 FV) 60' T-Scan /S4) IRS P-Scan (S4) 360.
- 42.
A A A A B B Quad Cities Unit 2 - Q2R25 N5A (Noz-Vessel) CODE CROSS-SECTIONAL AREA Required Exam Area Scanned Area Sq. in. Manual 17.9 0.6 19.8 17.0 4.3 4.3 4.3 4.3 19.8 12.1 4.3 0.0 Percent of Area Manual 1.4% 40.5% 10.2% 100.0% 28.8% 0.0% TOTAL CODE COVERAGE Weld Length Manual 360 290 290 360 70 70 % Total Composite Coverage = Comments: A - Manual scanning was limited due to the nozzle configuration. B - 60' S4 and S6 scans were restricted due lo the insulation support bracket. Examination volume is in accordance with Code Case N-613-2. Note
- Rounding methods may affect calculated values. UC-Underclad, FV-Full volume, NS-Near Surface. Weld length In degrees.
Percent Manual 0.7% 16.3% 4.1 % 50.0% 2.8% 0.0% 73.9% RO"lbod 10f10M3
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 31 of 73 N5A-NOZ (Contd) Comments: Ultrasonic examination resul w re acceptable to the requiremen of ASME B&PV Cod ction XI, 2007 Edition with the 2008 Addenda, as modified by the POI program d scription and th F deral Regist r, Part II, Nu lear Regulatory Comm* sion, 10 CFR Part SO for Category B-D, Full Penet tion Weld d Nozzles in Ve s Is. M nual radial scans wer p rformed in accordance with procedur G -UT~300 V12 (ORR' 13~34, 14~12, 14-2 a d 19*01) usi g a Go* RL search unit. Manual nozzle inner 15%T circumferential cans were performed in accordance with procedure GE*UT-311 V19 (ORR 14-24) using mod I valid t d earch unit angl Manual scanning a p rformed from the v I OD plate surfac. Manual sea ning was restricted due to th nozzl configuration and an insulation support bracket. No fla ~ indication were recorded. Achieved coverag = 73.9%.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 32 of 73 N6A-NOZ (Head spray nozzle to RVP) Quad CitiesUnit 2 (Q2R23) N6A Top Head Spray Nozzle Coverage Plot Bottom Side Coverage 60° S6 NS Exom Volume = 4.8 Sq. In. 60° S6 FV Exam Volume= 8.2 Sq. In. 60°S4 Exam Volume = 1.9 Sq. In. Inner 15%T 55 Exam Volume= 1.9 Sq. In. 60° S6 NS Exam Volume Achieved= 2.0 Sq. In. 60° 56 FV Exam Volume Achieved = 8.1 Sq. In. 60°S4 Exam Volume Achieved ~ 1.9 Sq. n. Inner 15% T S5 Exam Volume Achieved
- 1.9 Sq. In.
f _I] d.. Qua C1t1es Unit 2 Top Head Spray N6 Top Side Coverage 60° 56 NS Exam '/olume = 14.3 Sq. In. 60° 56 FV Exam Volume = 16.4 Sq. In. 60°54 Exam Volume = 3. 7 Sq. In. Inner 15%T 55 Exam Volume= 3.7 Sq. In. 60° 56 NS Exam 'Jolume Achieved = 2.0 Sci. In. 60° S6 FV Exam Volume Achieved= 11.9 Sq. In. 60°S4 Exam Volume Achieved = 3. 7 Sq. In. Inner 15%T S5 Exam Volume Achieved= 3.7 Sq. In. 'i 60'T ~ 2* 6J*r / 10.0* 60'T
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 33 of 73 N6A-NOZ (Contd) Weld Length = 360. Exam Volume= 14.9 60° T-Scan (S6) A 60° T-Scan (S4) A IRS P-Scan !S5) A Exam Volume= 34.4 60° T-Scon (S6) B 60° T-Scon (S4) B IRS P-Scan (S51 B 60° T-Scan (S6) 60° T-Scan (S41 IRS P-Scan !SSI 60° T-Scan (S61 60° T-Scan (S41 IRS P-Scan (SSI 60° T-Scan (S61 60° T-Scan (54) IRS P-Scan !SSJ Quad Cities Unit-2, Q2R23, 2016 N6A NOZ CODE CROSS-SECTIONAL AREA Percent Required Exam Area of Area Area Sq. in. Scanned Scanned 13.0 10.1 67.8% 1.9 1.9 12.8% 1.9 1.9 12.8% 30.7 13.9 93.3% 3.7 3.7 24.8% 3.7 3.7 24.8% TOTAL CODE COVERAGE Length Scanned 180 180 180 180 180 180 % Total Composite Coverage= Comments: A - Manual scanning was restricted due to the nozzle configuration. from the bottom side of nozzle. B - Manual scanning was restricted due to the nozzle configuration. from the top side of nozzle. Note - This coverage calculation is valid for ASME Section XI, 2001 Edition w/ 2003 Addenda, 2004 Edition w/ No Addenda and the 2007 Edition w/ 2008 Addenda. Percent Scanned 16.9% 3.2% 3.2% 23.3% 6.2% 6.2% 59.1% Note - Rounding methods may affect calculated values. S6 - Supplement 6, S4 - Supplement 4, SS Supplement - 5. Weld length in degrees.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 34 of 73 N6A-NOZ (Contd) Comments: During the manual ultrasonic examination of the above referenced component, no recordable indications were observed. The inner 15% examination volume as defined by 10CFRS0 was performed per procedure GEH-UT-311 Ver. 19 utilizing search units validated by modeling. Circumferential examination of the outer 85% T volume is not required in accordance with the 2001 Edition with 2003 Addenda. Scanning was limited due to nozzle configuration. 59.1 % of the required examination volume was achieved. Examination volume is in accordance with Code Case N-613-1. Code Case changes required volume from 1/2T to1/2". This change lowers the total volume required to be scanned, which also lowers the coverage achieved. This examination meets the requirements of ASME Section XI, 2007 Edition through 2008 Addenda.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 35 of 73 RPV-THHF (Top head to flange weld) O" 0.3" <t_ 60-Y/P Quad Cities Unit-2 RPV-THH F S6 NS exam volume = 7.2 Sq. In. S6 FV exam volume= 16.9 Sq. In. S4 exam volume= 4.0 Sq. In. SGT NS examination volume achieved= 5.3 Sq. In SGT FV examination volume achieved = 16.8 Sq. In S4T LKDN examination volume achieved = 4.0 Sq. In S4T LKUP examination volume achieved= 0.0 Sq. In SGT NS examination volume achieved = 4.5 Sq. In SGT FV examination volume achieved = 11.5 Sq. In S4P LKCW examination volume achieved = 2.8 Sq. In S4P LKCC examination volume achieved = 2.8 Sq. In
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 36 of 73 RPV-THHF (Contd) Weld Length = Exam Volume = 60° T-Scon (S6 NS) 60° T-Scan IS6 FVI 60° T-Scon (S4 LKUP) 60° T-Scan (S4 LKDNI 60° P-Scan (S6 NSFV) 60° P-Scan (S6 FV) 60° P-Scan (S4 LKCWI 60° P-Scan IS4 LKCC) 60° T-Scan (S6 NS) 60° T-Scan IS6 FVI 60° T-Scon (S4 LKUPI 60° T-Scan (S4 LKDN) 60° P-Scon IS6 NSFV) 60° P-Scan (S6 FVI 60° P-Scon (S4 LKCW) 60° P-Scon IS4 LKCCI 360.0 28.1 A A A A A A A A Quad Cities Unit-2 RPV-THHF (Top Head to Flange) CODE CROSS-SECTIONAL AREA Required Exam Area Sq. in. 7.2 16.9 4.0 4.0 7.2 16.9 4.0 4.0 Area Examined 5.3 16.8 0.0 4.0 4.5 11.5 2.8 2.8 TOTAL CODE COVERAGE Percent of Area Examined 18.9% 59.8% 0.0% 14.2% 16.0% 40.9% 10.0% 10.0% Weld Length Examined 360.0 360.0 360.0 360.0 360.0 360.0 360.0 360.0 % Total Composite Coverage= Comments: A - Manual scanning was limited due to the flange configuration. Note - Roundino methods may affect calculated values. S4 - Supplement 4, S6 - Supplement 6 volume. Weld length in inches. Percent Examined 9.4% 29.9% 0.0% 3.6% 8.0% 20.5% 2.5% 2.5% 76.3% Rev. 2/ZZllOI!
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 37 of 73 RPV-THHF (Contd) Comments: Ultrasonic examination results were unacceptable to the requirements of ASME B&PV Code Section XI, 2007 Edition with the 2008 Addenda. as modified by the POI program description and the Federal Register, Port II, Nuclear Regulatory Commission. 10 CFR Port 50 for Category 8-A Reactor Pressure Vessel (RPV) Assembly Welds. Manual transverse and parallel scans were performed in accordance with procedure GEH-UT-300 V. 12 using 60° RL search units. Manual scanning was performed from the vessel OD surface and was restricted due to the flange configuration. Manual sizing scans were performed in accordance with procedure GEH-UT-304 V. 10 using 45°S search units. Five (5) recordable indications were detected and evaluated as being unacceptable to the requirements of IWB-3000. The recorded indications were correlated to previously recorded unacceptable indications from 1990 initially detected by visual examinations from the head inside surface. The correlation shows essentially no change from the previous results other than normal deviations due to ultrasonic uncertainties. Reference Q2R24-R-11 for additional information regarding supplemental examinations performed under the License Renewal Program. Achieved coverage = 76.3%.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 38 of 73 RPV-VSC1-77 79° / 173.3"
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 39 of 73 RPV-VSC1-77 (Contd) ~ JI C9111H 1 CCW Supplement 4 Exam Votume "' 8.8 sq. in. Supplement 6 Exam VOiume : 50.9 sq. in. S4 T-Scan Achieved: 8.8 sq. in. S4 P-Scan Achieved "'8.8 sq. in. S6 T-Scan Achieved : 50.9 sq. in. S6 P-Scan Achieved= 50.9 sq. in. Nominal dad T = 0.1875 in. Norn nal shell T "'6.375 n. -t-i I I I Weld width shown as 2.75" by UT Weld position was relocated by UT during the 1997 examinations. Previous location was n
- Az..
Sh.. COY<k 1 CW
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 40 of 73 RPV-VSC1-77 (Contd) Weld Length = Exam Volume = so* T -Scan (S4 NS) 45° T-Scan (SS FV) so* P-Scan (S4 NS) 45° P-Scan (S6 FV) so* T-Scan (S4 NS) 45° T-Scan (SS FV) so* P-Scan (S4 NS) 45° P-Scan (SS FV) so* T -Scan (S4 NS) 45° T-Scan (SS FV) so* P-Scan (S4 NS) 45° P-Scan (SS FV) so* T-Scan CS4 NS) 45° T-Scan (SS FV) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) 133.50 59.70 A A A A B B B B Comments: A - Automated scanning was not restricted. Quad Cities Unit-2 RPV-VSC1-77 CODE CROSS-SECTIONAL AREA Required Exam Area Scanned Area Sq. in. Automated 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 8.8 0.0 50.9 0.0 B - Automated scanning limited due to drive axis limitation. TOTAL CODE COVERAGE Percent of Area Weld Length Percent Automated Automated Automated 14.7% 118.00 S.5% 85.3% 118.00 37.7% 14.7% 118.00 S.5% 85.3% 118.00 37.7% 14.7% 2.40 0.1% 85.3% 2.40 0.8% 0.0% 0.00 0.0% 0.0% 0.00 0.0% % Total Composite Coverage= 89.3% Note - Rounding methods may affect calculated values. FV-Full volume. NS-Near Surface. Weld length in inches. RfY, Q ~
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 41 of 73 RPV-VSC1-77 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed in the head down orientation to obtain all accessible areas along the weld length. Examinations were limited due to the clearance between the jet pump diffusers and the vessel wall. For limitations and examination coverage see pages 3 and 6. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero.. and clockwise looking down. Coverage calculated In accordance with the applicable ASME Section XI, IWB-2500 Figure-89.3%. Code case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the PDI program description and 10CFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 42 of 73 RPV-VSC1-197 L 436.1" VI ~ ,:s., C: C: e V'I
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 43 of 73 RPV-VSC1-197 (Contd) Shell Courw t c~ Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume= 50.9 sq. in. S4 T-Scan Achieved= 8.8 sq. in. S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved= 50.9 sq. in. Nominal clad T = 0.1875 in. Nominal shell T = 6.375 in.
- 34
- 199* Ar.
-t-i I I I Weld width shown as 2.75" by UT 60'T/P t5' T/P 60'T t S'T I weld positiOn was relocated by UT during the 1997 examinations. Previous location WfS 197° ~ - Sltell Coutff I CV'f
RPV-VSC 1-197 (Cont'd) ATTACHMENT 3 10 CFR 50.55a Relief Request ISR-26, Revision 0 Additional Details and Supporting Information - Unit 2 Quad Cities Unit-2 RPV-VSC1-197 CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Weld Length = Exam Volume = 60° T-Scan (S4 NS) 45° T-Scan S6 FV) 60° P-Scan S4 NS 45° P-Scan (S6 FV) so* T-Scan (S4 NS 45° T-Scan S6 FV) 60° P-Scan S4 NS 45° P-Scan (S6 FV) 60° T-Scan S4 NS) 45° T-Scan S6 FV) so* P-Scan S4 NS 45° P-Scan (S6 FV) 60° T-Scan S4 NS 45° T-Scan S6 FV 60° P-Scan S4 NS 45° P-Scan (S6 FV) 133.50 59.70 A A A A Required Exam Area Sq. in. 8.8 50.9 8.8 50.9 Comments: A - Exam limited due to lower shroud repair support. Area Scanned Automated 8.8 50.9 8.8 50.9 Percent of Area Weld Length Automated Automated 14.7% 56.90 85.3% 56.90 14.7% 55.00 85.3% 56.90 % Total Composite Coverage = Note - Rounding methods mav affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. Page 44 of 73 Percent Automated
- 3. 1%
18.2% 3.0% 18.2% 42.5% Rov. 09/23/0!
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 45 of 73 RPV-VSC1-197 (Contd) During the examination of the above referenced weld, no recordable Indications were detected. Transverse and parallel examinations were performed In accordance with procedure GEH-UT-737 V.0 utilizjng 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed in the head down and head up orientations to obtain all accessible areas along the weld length. Examinations were limited due to the lower shroud repair support For limitations and examination coverage see pages 3, 6, and 7. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-42.5%. Code case N-768 does not provide any additional coverage for this !Imitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the PDI program description and 1 0CFR50.56a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 46 of 73 RPV-VSC1-317 r---. M I"') I M / 270" ~ /" > I "'~" 1 53" 156" 699.0 11 ~ -0 C C u Vl I I I _J ____./ 699.0 11 ~ -0 C C u Vl
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 47 of 73 RPV-VSC1-317 (Contd) , 5*T .$hell Courso 1 eew Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume = 50.9 sq. in. S4 T-Scan Achieved= 8.8 sq. in. S4 P-Scan Achieved= 8.8 sq. in. S6 T-Scan Achieved"' 50.9 sq. in. S6 P-Scan Achieved = 50.9 sq. in. Nominal clad T = 0.1875 in. Nominal shell T = 6.375 in. <t. 699.0" 319' Al. -t-i I I I Weld width shown as 2.75" by UT 60' T/P
- S' T/P 60' T
'5"T Weld position was relocated by UT during the 1997 examinations. Previous location was 317° A2. Sh,11 C~rH 1 CW
RPV-VSC1-317 (Cont'd) SM C-ICCW
- Supplement 4 Exam Volume = 8.8 sq. In.
Supplement 6 Exam Volume = 50.9 SQ. in. $4 T-Scan Ad'l eved = 8.8 sq. rn. S4 P-Sean Achieved = 8.8 sq. In. $6 T-Scan Achieved "' 50.6 SQ. in. $6 P-Scan Achieved = 50.9 sq. In. ominal clad T = 0.1875 in. Nominal shel T
- 6.375 in.
ATTACHMENT 3 10 CFR 50.55a Relief Request ISR-26, Revision 0 Additional Details and Supporting Information - Unit 2 6tttr M -t-i I I I 'I/veld width shown as 2.75" by UT <<50'T/P ~ 'TIP 00.,. 45' I Weld position was relocated by I.IT during the 1997 examnations. Previous location was 317° Az.. Page 48 of 73 Sh Courw1CW
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 49 of 73 RPV-VSC1-317 (Contd) $hell C-1 C<::W Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume = 50.9 sq. in. S4 T-Scan Achieved= 7.2 sq. in. S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved"' 42.1 sq. in. S6 P-Scan Achieved = 50.9 sq. in. Nominal clad T = 0.1875 in. Nominal shell T = 6.375 in. 319" Iv. 60'P Weld width shown as 2.75" by UT Weld POsition was relocated by ur during the 1997 examinations. Previous location was 31 r A7..
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 50 of 73 RPV-VSC1-317 (Contd) Weld Length = Exam Volume = 60° T-Scan (S4 NS) 45° T-Scan (S6 FV) 60° P-Scan (S4 NS) 45" P-Scan (S6 FV) 60° T -Scan (S4 NS) 45° T-Scan (S6 FV) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) 60° T-Scan (S4 NS) 45° T-Scan CS6 FV) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) 60° T-Scan (S4 NS) 45° T-Scan (S6 FV) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) 133.50 59.70 A A A A B B B B C C C C Comments: A - Automated scanning was not restricted. Quad Cities Unit-2 RPV-VSC1-317 CODE CROSS-SECTIONAL AREA Required Exam Area Scanned Area Sq. in. Automated 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.6 8.8 8.8 50.9 50.9 8.8 7.2 50.9 42.1 8.8 8.8 50.9 50.9 B - Automated scanning restricted -4.0" due to the proximity of the JP diffuser. C - Automated scanning restricted -1.6" due to the proximity of the JP diffuser. TOTAL CODE COVERAGE Percent of Area Weld Length Percent Automated Automated Automated 14.7% 95.00 5.2% 85.3% 95.00 30.3% 14.7% 95.00 5.2% 85.3% 95.00 30.3% 14.7% 7.50 0.4% 84.8% 7.50 2.4% 14.7% 7.50 0.4% 85.3% 7.50 2.4% 12.1% 3.00 0.1% 70.5% 3.00 0.8% 14.7% 3.00 0.2% 85.3% 3.00 1.0% % Total Composite Coverage= 78.8% Note - Rounding methods may affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. Rev O 9123105
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 51 of 73 RPV-VSC1-317 (Contd) During the examination of the above referenced weld, one indication was recorded. This indication was previously recorded in 1997, and was evaluated as having no thru-wall dimension. The current examination results show no change in the flaw characteristics, therefore the indication is accpetable per IWB-3000. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was perfonned in the head up and head down orientations to obtain all accessible areas along the weld length. Additional ! scans in the head up configuration were performed at the Intersection of CW-C1C2 weld, due to excessive plate mismatch. Scanning was limited due to the proximity of the jet pump 20 sensing line bracket and the N1 penetration. For limitations and examination coverage see pages 4 and 9. For additional details, see the attached drawings, and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-78.8%. Code case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the PDI program description and 1 OCFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 52 of 73 RPV-VSC2-22 C 0., ~ C .g C r! 0 u
- c.
-=
- t C
0 0 C u "0
- a.
-0
- c
- c V,
~ "0., C I~ -0 C
- 3 C
C V, I u V)
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 53 of 73 RPV-VSC2-22 (Contd) Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume = 50.9 sq. in. S4 T-Scan Achieved= 8.8 sq. in. S4 P-Scan Achieved = 8.8 sq. In. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved= 50.9 sq. in. Nominal dad T = 0.1875 in. Nomfnal shell T :: 6.375 rn. -t-Sl\tn COUIM2CW i I I I Weld width shomi as 2.75* by UT
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 54 of 73 RPV-VSC2-22 (Contd) Shel Courw 2CCW Supplement 4 xam Volume = 8.8 sq. in. Supplement 6 Exam Volume 50.9 sq. in. S4 T-Scan Achieved= 8.8 sq. In. S4 P-Scan Achleved = 8.8 sq. *. S6 T-Scan Achieved = 50.9 sq. in. S6 P-Sean Achieved = 50.9 sq. in. Nominal dad T 0.1075 In. Nominal shell T = 6.375 in. 22' Al
- shtl C 2CW Weld width s:hown as 2.75" by uT
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 55 of 73 RPV-VSC2-22 (Contd) Quad Cities Unit-2 RPV-VSC2-22 CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Weld Length = Exam Volume = so* T-Scan (S4 NS) 45* T-Scan lS6 FV) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) so* T-Scan (S4 NS) 45° T-Scan (S6 FV) so* P-Scan (S4 NS) 45° P-Scan (S6 FV) 60° T-Scan (S4 NS) 45° T-Scan (S6 FV) so* P-Scan (S4 NS) 45° P-Scan (S6 FV) so* T-Scan (S4 NS) 45° T-Scan (S6 FV) 60° P-Scan <S4 NS\ 45° P-Scan (S6 FV) 133.00 59.70 A A A A 8 8 8 8 Required Exam Area Sq. in. 8.8 50.9 8.8 50.9 8.8 50.9 8.8 50.9 Percent Area Scanned of Area Weld Length Automated Automated Automated 8.8 14.7% 65.50 50.9 85.3% 65.50 8.8 14.7% 65.50 50.9 85.3% 65.50 8.8 14.7% 12.00 50.9 85.3% 12.00 8.8 14.7% 12.00 50.9 85.3% 12.00 % Total Composite Coverage= Comments: A - Automated scanning was not restricted. B - Automated scanning was restricted due to the proximity of the tie rod mid support bracket. Scanning was limited due to the shroud repair tie rod hardware. Percent Automated 3.6% 21.0% 3.6% 21.0% 0.7% 3.8% 0.7% 3.8% 58.3% A 2 inch section of the scanned area was deleted from the coverage due to a local area of liftoff. Rescanning did not improve contact. Visual clad disruption ovserved in the area of liftoff. Note - Rounding methods may affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. ROY. 0 9/23.&.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 56 of 73 RPV-VSC2-22 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.0 utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed in the head up and head down orientations to obtain all accessible areas along the weld length. Scanning was limited due to the shroud repair. The upper portion of the weld was restricted totally, due to the design and location of the upper repair support. Scanning was performed in the middle section of the weld in both head up and head down configurations up to and Inside of the middle repair support. The lower portion of the weld had to be examined in the head up configuration only up to and inside the middle repair support. Coverage was achieved inside the middle repair support using single side access. For limitations and examination coverage see pages 3, 7, and 8. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated In accordance with the applicable ASME Section XI, IWB-2500 Figure-58.3%. Code case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the POI program description and 10CFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 57 of 73 RPV-VSC3-77 81° 138.3" 221.~ 138.3" 0 a 1 I t.f) u (/) . 7" 534" 221.~ 0 ~ u C C ::
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 58 of 73 RPV-VSC3-77 (Contd) $hell Courso 3 CCW Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume = 50.9 sq. in. S4 T-Scan Achieved= 8.8 sq. in. S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved = 50.9 sq. in. Nominal dad T = 0.1875 in. Nominal shell T = 6.375 in. nr s1*~ -+- I I I I Weld width shown as 2.75" by UT 60"TIP 45' TIP 60'T 45'T Weld position was relocated by UT during the 1997 examinations. Previous location was 77° Az. Shell Course 3 CW
RPV-VSC3-77 (Cont'd) ATTACHMENT 3 10 CFR 50.55a Relief Request ISR-26, Revision 0 Additional Details and Supporting Information - Unit 2 Quad Cities Unit-2 RPV-VSC3-77 CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Weld Length = Exam Volume = 60° T-Scan S4 NS 45° T-Scan S6 FY) 60° P-Scan S4 NS 45° P-Scan (S6 FV) 60° T-Scan S4 NS 45° T-Scan S6 FY) so* P-Scan S4 NS 45° P-Scan (S6 FV) 60° T-Scan S4 NS 45° T-Scan S6 FV 60° P-Scan S4 NS 45" P-Scan (S6 FV) 60° T-Scan S4 NS 45° T-Scan S6 FV so* P-Scan S4 NS 45° P-:scan (S6 FY) 133.00 Required Exam 59.70 Area Sq. in. A 8.8 A 50.9 A 8.8 A 50.9 B 8.8 B 50.9 B 8.8 B 50.9 Comments: A -Area scanned below core spray and feedwater piping B-Area scanned above core spray and feedwater piping. Percent Area Scanned of Area Weld Length Automated Automated Automated 8.8 14.7% 63.90 50.9 85.3% 63.90 8.8 14.7% 62.00 50.9 85.3% 63.90 8.8 14.7% 31.90 50.9 85.3% 30.00 8.8 14.7% 31.90 50.9 85.3% 31.90 % Total Composite Coverage = Note - Rounding methods may affect calculated values. FY-Full volume, NS-Near Surface. Weld length in inches. Page 59 of 73 Percent Automated 3.5% 20.5% 3.4% 20.5% 1.8% 9.6% 1.8% 10.2% 71.3% Rev. 0 9123/0S
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 60 of 73 RPV-VSC3-77 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed In the head up and head down orientations to obtain all accessible areas along the weld length. An additional scan in the clockwise configuration was performed due to mismatch between shell course three and the CW-C3C4 weld to optimize contact. Scanning was limited due to the feedwater spargers and corespray piping. For limitations and examination coverage see pages 2, 6 and 7. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-71.3%. Code Case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the POI program description and 10CFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 61 of 73 RPV-VSC3-197 534" 201° I 484.~ 484.~ 501.5" ~ ~I ' 8~::;J1~ -\- 464" C C C C C ~ .x 435" 425"
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 62 of 73 RPV-VSC3-197 (Contd) Sllol course 3 CCVI/ Supplement 4 Exam Volume = 8.8 sq. n. Supplement 6 Exam Volume= 50.9 sq, in. S4 T-Scan Actueved = 8.8 sq. in. S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved = 50.9 sq. in. Nominal dad T = 0.1875 in. Nominal shell T = 6.375 in. <<o.s* 201* ~ -t-i I I I Weld width shown as 2. 75" by UT ,s I Weld position was relocated by UT during the 1997 examinations. Previous location was 197* Az. Shel C..ur,uo 3 CVI/
RPV-VSC3-197 (Cont'd) ATTACHMENT 3 10 CFR 50.55a Relief Request ISR-26, Revision 0 Additional Details and Supporting Information - Unit 2 Quad Cities Unit-2 RPV-VSC3-197 CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Weld Length = Exam Volume= so* T-Scan (S4 NS 45° T-Scan (SS FV) so* P-Scan (S4 NS 45* P-Scan <S6 FV) so* T-Scan (S4 NS) 45° T-Scan (SS FV) so* P-Scan (S4 NS 45° P-Scan (SS FV) 60° T-Scan (S4 NS 45° T-Scan {S6 FV 60° P-Scan (S4 NS 45° P-Scan (S6 FV) so* T-Scan (S4 NS 45° T-Scan (S6 FV 60° P-Scan (S4 NS 45° P-scan (S6 FV 133.00 Required Exam 59.70 Area Sq. in. A 8.8 A 50.9 A 8.8 A 50.9 B 8.8 B 50.9 B 8.8 B 50.9 Comments: A -Area scanned below core spray and feedwater piping 8-Area scanned above core spray and feedwater piping. Percent Area Scanned of Area Weld Length Percent Automated Automated Automated Automated 8.8 14.7% 74.90 4.2% 50.9 85.3% 73.00 23.4% 8.8 14.7% 74.90 4.2% 50.9 85.3% 74.90 24.0% 8.8 14.7% 1S.00 0.9% 50.9 85.3% 16.00 5.1% 8.8 14.7% 16.00 0.9% 50.9 85.3% 1S.00 5.1% % Total Composite Coverage= 67.7% Note - Rounding methods may affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. Page 63 of 73 Rev. 0 912310:
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 64 of 73 RPV-VSC3-197 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed in the head up and head down orientations to obtain all accessible areas along the weld length. Scanning was limited due to the feedwater spargers, corespray piping, and guide rod brackets. For limitations and examination coverage see pages 3, 6, and 7. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-67.7%. Code Case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the POI program description and 10CFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 65 of 73 RPV-VSC3-317 383" 321° u V) I"') I I") u V) 703.2" ~.... ~ "'0.. C C e <I)
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 66 of 73 RPV-VSC3-317 (Contd)
- Shell Coutst 1 CCW Supplement 4 Exam Volume = 8.8 sq. n.
Supplement 6 Exam Volume = 50.9 sq. In. S4 T-Scan Achieved= 8.8 sq. in. S4 P-Scan Achieve<!= 8.8 sq. in. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved "' 50.9 sq. in. Nominal clad T := 0.1875 in. Nominal shell T = 6.375 in. ecrr 6tl'T/P
- s*r/P
<t. 699 0-319" Az. -t-i I I I Weld width shown as 2. 75" by UT 60' T/P 4S' T/P 45'T I Weld position was relocated by UT during the 1997 examinations. Previous location was 317* Az.. Shel1 Cou,v1Cw
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 67 of 73 RPV-VSC3-317 (Contd) Weld Length = Exam Volume = 60° T-Scan (S4 NS) 45° T-Scan (S6 FY) 60° P-Scan (S4 NS) 45° P-Scan (S6 FV) so* T-Scan CS4 NS) 45° T-Scan (S6 FY) so* P-Scan (S4 NS) 45° P-Scan (S6 FV) so* T-Scan (S4 NSl 45° T-Scan (S6 FY) so* P-Scan (S4 NS) 45° P-Scan (S6 FY) so* T-Scan (S4 NS) 45° T-Scan (S6 FY) so* P-Scan (S4 NS) 45 ° P-Scan (S6 FV) 133.00 59.70 A A A A B B B B Quad Cities Unit-2 RPV-VSC3-317 CODE CROSS-SECTIONAL AREA Required Exam Area Scanned Area Sq. in. Automated 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 8.8 8.8 50.9 50.9 Comments: A -Area scanned below core spray and feedwater piping B-Area scanned above core spray and feedwater piping. TOTAL CODE COVERAGE Percent of Area Weld Length Percent Automated Automated Automated 14.7% 73.90 4.1% 85.3% 73.90 23.7% 14.7% 72.00 4.0% 85.3% 73.90 23.7% 14.7% 31.60 1.8% 85.3% 22.60 7.2% 14.7% 30.00 1.7% 85.3% 31.60 10.1% % Total Composite Coverage= 76.2% Note - Rounding methods may affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. Rev. 0 9123105
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 68 of 73 RPV-VSC3-317 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was performed in the head up and head down orientations to obtain all accessible areas along the weld length. Scanning was limited due to the feedwater spargers, and corespray piping. For limitations and examination coverage see pages 3, 6, and 7. For additional details, see the attached drawings and screen prints. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-76.2%. Code Case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the POI program description and 1 OCFR50.55a.
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 69 of 73 RPV-VSC4-219 585" 570" 221 ° I \ ) @@@@@@ 58 @'@@@~ v~.. as"l'I ~ ~01° 609.6" 594" 535" 513" ( ~ ~ <( -0., C: C: Sl
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 70 of 73 RPV-VSC4-219 (Contd) $neb Course 4 CCW Supplement 4 Exam Volume:: 8.8 sq. in. Supplement 6 Exam Volume : 50.9 sq. in. S4 T-Scan Achieved = 8.8 sq. in S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved= 50.9 sq. in. S6 P-Scan Achieved = 50.9 sq. in. Nominal clad T :: 0.1875 in. Norn nal shell T = 6.375 in. eo* '60"l/P
- s*11P
- s.c T
- 221* /U
-t-i I I I Weld width shown as 2.7S* by UT Weld position was relocated by UT during the 1997 examinations. Previous location was 219" Az.. Shel Course 4 CJIV
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 71 of 73 RPV-VSC4-219 (Contd) Shel Courw 4 CCW Supplement 4 Exam Volume = 8.8 sq. in. Supplement 6 Exam Volume= 50.9 sq. in. S4 T-Scan Achieved = 8.6 sq. In. S4 P-Scan Achieved = 8.8 sq. in. S6 T-Scan Achieved"' 49.7 sq, In. S6 P-Scan Achieved= 50.9 sq. in. Nominal clad T = 0.1875 in. Nominal shell T = 6.375 In. -~*, -t-i I I I Weld vidth shown as 2.75" by UT Weld position was relocated by UT during the 1997 examinations. Previous location was i19* /q. sne*c~*ew
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 72 of 73 RPV-VSC4-219 (Contd) Quad Cities Unit-2 RPV-VSC4-219 CODE CROSS-SECTIONAL AREA TOTAL CODE COVERAGE Weld Length = Exam Volume = so* T-Scan (S4 NS 45* T-Scan (S6 FV so* P-Scan (S4 NS 45° P-Scan (SS FV) so* T-Scan (S4 NS) 45° T-Scan (S6 FV) so* P-Scan (S4 NS 45° P-Scan (S6 FV) so* T-Scan (S4 NS 45° T-Scan (S6 FV) so* P-Scan (S4 NS 45* P-Scan (S6 FV) so* T -Scan (S4 NS 45° T-Scan (S6 FV so* P-Scan (S4 NS> 45° P-Scan (S6 FV) 129.50 Required Exam 59.70 Area Sq. in. A 8.8 A 50.9 A 8.8 A 50.9 B 8.8 B 50.9 B 8.8 B 50.9 Percent Area Scanned of Area Weld Length Automated Automated Automated 8.8 14.7% 91.50 50.9 85.3% 91.50 8.8 14.7% 91.50 50.9 85.3% 91.50 8.6 14.4% 14.00 49.7 83.2% 14.00 8.8 14.7% 14.00 50.9 85.3% 14.00 % Total Composite Coverage = Comments: A - Automated scanning was not restricted. B - Automated scanning was restricted due to the proximity of an instrumentation nozzle. Automated scanning was limited due to the proximity of a steam dryer support bracket weld pad buildup. Note - Rounding methods may affect calculated values. FV-Full volume, NS-Near Surface. Weld length in inches. Percent Automated 5.2% 30.1% 5.2% 30.1% 0.8% 4.5% 0.8% 4.6% 81.3% Rav. O 912=
ATTACHMENT 3 10 CFR 50.55a Relief Request I5R-26, Revision 0 Additional Details and Supporting Information - Unit 2 Page 73 of 73 RPV-VSC4-219 (Contd) During the examination of the above referenced weld, no recordable indications were detected. Transverse and parallel examinations were performed in accordance with procedure GEH-UT-737 V.O utilizing 45° shear wave search units for the Supplement 4 and 6 examinations, along with 60° longitudinal wave search units for Supplement 4 examinations. Scanning was perfonned in the head up and head down orientations to obtain all accessible areas along the weld length. Scanning was limited due to the dryer support lug and the N 11 B nozzle. Coverage calculations in the area of these obstrucitons were achieved with single side access. For limitations and examination coverage see pages 2 and 3. For additional details, see the attached drawings, screen prints, and data sheets. All references to azimuth within this package are taken from "vessel zero" and clockwise looking down. Coverage calculated in accordance with the applicable ASME Section XI, IWB-2500 Figure-81.3%. Code Case N-768 does not provide any additional coverage for this limitation. Ultrasonic examinations were performed to the requirements of ASME Section XI, Appendix VIII as modified by the POI program description and 10CFR50.55a.}}