ML23229A536
| ML23229A536 | |
| Person / Time | |
|---|---|
| Site: | 99902100 |
| Issue date: | 08/14/2023 |
| From: | Jessup W NRC/NRR/DANU/UAL1 |
| To: | George Wilson TerraPower |
| References | |
| EPID L-2023-LRO-0015 | |
| Download: ML23229A536 (2) | |
Text
August 14, 2023 Mr. George Wilson Vice President, Regulatory Affairs TerraPower, LLC 15800 Northup Way Bellevue, WA 98008
SUBJECT:
TERRAPOWER, LLC - U.S. NUCLEAR REGULATORY COMMISSION STAFF FEEDBACK AND OBSERVATIONS REGARDING NAT-3049, NASCENT THERMAL HYDRAULIC MODEL WHITE PAPER (EPID NO. L-2023-LRO-0015)
Dear Mr. Wilson:
By letter dated March 20, 2023 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML23080A013), TerraPower, LLC (TerraPower) submitted NAT-3049, Nascent Thermal Hydraulic Model White Paper (ML23080A014, non-public) for the U.S.
Nuclear Regulatory Commission (NRC) staffs review. The NRC staffs feedback and observations on the white paper are provided in the enclosure to this letter.
If you have any questions regarding this matter, please contact Mallecia Sutton, at 301-415-0673 or via email at Mallecia.Sutton@nrc.gov.
Sincerely, William Jessup, Chief /RA/
Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 99902100
Enclosure:
As stated cc: TerraPower Natrium via GovDelivery
Enclosure:
ML NRR-106 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL1:LA NRR/DANU/UTB2 NAME MSutton DGreene RAnzalone DATE 8/7/2023 8/10/2023 8/13/2023 OFFICE NRR/DANU/UTB2:BC NRR/DANU/UAL1:BC NAME CdeMessieres WJessup DATE 8/14/2023 8/14/2023