ML23173A045

From kanterella
Jump to navigation Jump to search

9 to Updated Final Safety Analysis Report, Chapter 9, Table of Contents - Redacted
ML23173A045
Person / Time
Site: Peach Bottom  Constellation icon.png
Issue date: 04/10/2023
From:
Constellation Energy Generation
To:
Office of Nuclear Reactor Regulation
Shared Package
ML23172A253 List:
References
EPID: L-2023-LRO-0038
Download: ML23173A045 (1)


Text

PBAPS UFSAR CHAPTER 09 9-i REV. 26, APRIL 2017 SECTION 9.0 - RADIOACTIVE WASTE SYSTEMS TABLE OF CONTENTS SECTION TITLE 9.1

SUMMARY

DESCRIPTION 9.2 LIQUID RADWASTE SYSTEM 9.2.1 Power Generation Objective 9.2.2 Power Generation Design Basis 9.2.3 Safety Design Basis 9.2.4 Description 9.2.4.1 General 9.2.4.2 Collection Subsystems 9.2.4.2.1 Equipment Drain Subsystem for Low Conductivity Radioactive Waste 9.2.4.2.2 Floor Drain Subsystem for Higher Conductivity Radioactive Waste 9.2.4.2.3 Chemical Waste Subsystem for Radioactive Chemical Wastes 9.2.4.2.4 Laundry Drain Subsystem for Liquid Waste Containing Cleaning Agents 9.2.4.3 Environmental Discharge Subsystem 9.2.4.4 Radiation Monitoring on Auxiliary Cooling Water Discharges 9.2.4.5 Non-Aqueous Liquid Radwastes 9.2.5 Quantity of Radioactive Wastes 9.2.6 Tritium in Liquid Wastes 9.2.6.1 General 9.2.6.2 Sources of Tritium in the Reactor 9.2.7 Limits of Release of Radioactive Wastes to the Environment 9.2.8 Power Generation Evaluation 9.2.9 Safety Evaluation 9.2.10 Inspection and Testing 9.3 SOLID RADWASTE SYSTEM 9.3.1 Power Generation Objective 9.3.2 Power Generation Design Basis 9.3.3 Description 9.3.3.1 General 9.3.3.2 Wet Solid Radwaste 9.3.3.3 Dry Wastes 9.3.3.4 Reactor Internal Parts 9.3.4 Power Generation Evaluation 9.3.5 Inspection and Testing

PBAPS UFSAR TABLE OF CONTENTS (cont'd)

SECTION TITLE CHAPTER 09 9-ii REV. 26, APRIL 2017 9.4 GASEOUS RADWASTE/OFF-GAS SYSTEM 9.4.1 Power Generation Objective (Common) 9.4.2 Power Generation Design Basis9.4.3 Safety Design Basis 9.4.4 Description 9.4.4.1 General 9.4.4.2 Steam Jet Air Ejector Subsystem 9.4.4.2.1 Component Description 9.4.4.3 Gland Seal Steam Exhauster Subsystem 9.4.4.4 Standby Gas Treatment System 9.4.4.5 Hydrogen Water Chemistry System 9.4.5 Safety Evaluation 9.4.6 Inspection and Testing

PBAPS UFSAR CHAPTER 09 9-iii REV. 26, APRIL 2017 SECTION 9.0 - RADIOACTIVE WASTE SYSTEMS LIST OF TABLES TABLE TITLE 9.2.1 Equipment Drain Sumps 9.2.2 Liquids Collected in Waste Collector Tank 9.2.3 Floor Drain Sumps 9.2.4 Collection of Radioactive Liquid Waste, Units 2 and 3 9.2.5 Expected Quantities of Liquid Radwaste Released from Units 2 and 3 9.2.6 Typical Relative Isotopic Concentrations of Significant Radioisotopes in Discharge Canal 9.2.7 DELETED 9.2.7a Maximum Inventory of Liquid Radwaste in Permanent Tankage 9.2.7b Maximum Permissible Concentration (MPC) of Radioactive Material in Undiked Liquid Holdup Tanks 9.2.8 Estimated Annual Curie Release in Liquid Effluent 9.2.8B Deleted 9.4.1 Off-Gas System Design Bases 9.4.2 Gaseous Radwaste Input to the Main Adsorber Bed 9.4.2B Deleted 9.4.3 Gaseous Radwaste Effluent Data Fission Product Noble Gases and Activation Gases 9.4.3B Deleted 9.4.4 Unit 2 Gaseous Radwaste Input and Inventory in the Main Adsorber Bed for Accident Analysis 9.4.4B Deleted

PBAPS UFSAR CHAPTER 09 9-iv REV. 26, APRIL 2017 SECTION 9.0 - RADIOACTIVE WASTE SYSTEMS LIST OF FIGURES FIGURE TITLE 9.2.1A Deleted 9.2.1B Deleted 9.2.2 Deleted 9.2.3 Deleted 9.2.4a Deleted 9.2.4b Equipment Location, Reactor and Radwaste Building Plan 9.2.4c Deleted 9.2.4d Equipment Location, Radwaste Building Plan 9.2.4e Equipment Location, Reactor and Radwaste Building Plan 9.2.5 Site Plan Showing Principal Liquid Radioactive Waste Facilities 9.2.6 Condensate and Refueling Water Storage Systems 9.2.7 Unit 2, Service Water System 9.2.8 Emergency Service Water and High Pressure Service Water Systems 9.3.1 Deleted 9.3.2 Deleted 9.4.1 Deleted Security-Related Information Withheld under 10 CFR 2.390 Security-Related Info Security-Related Information Withheld under 10 CFR 2.390