31st NUPIC Vendor Conference June 14 - 15, 2023, Denver, Co - Regulatory Process for Code Cases and ASME Code Case N-883
ML23158A087
Person / Time
Issue date: 06/07/2023
From: Yamir Diaz-Castillo
NRC/NRR/DRO/IQVB
To:
References
Download: ML23158A087 (11)


Text

1 31st Annual NUPIC Vendor Conference Regulatory Process for Code Cases and ASME Code Case N-883 Yamir Diaz-Castillo NRR/DRO/IQVB June 14 - 15, 2023

Agenda

  • Background
  • Regulatory Process for Code Cases
  • Next Steps
  • Questions and Contact Information

=

Background===

  • What is the purpose of a Code Case?

- To clarify the intent of existing requirements.

- To allow early implementation of an approved Code revision.

- To provide, when there is an urgent need, rules for materials or construction not covered by existing Code rules.

Regulatory Process

  • Lists the Editions and Addenda, Regulatory Guides (RG), and Code Cases that have been approved by incorporation by reference in the regulation.

Regulatory Process

  • RG 1.147, Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1, Revision 20, dated December 2021
  • RG 1.192, Operation and Maintenance Code Case Acceptability, ASME OM Code, Revision 4, December 2021
  • RG 1.193, ASME Code Cases Not Approved for Use, Revision 7, dated December 2021

Regulatory Process

  • RG 1.84 identifies Code Cases the NRC has determined to be acceptable alternatives to applicable parts of Section III of the ASME B&PV Code.

- Provide an acceptable level of quality and safety, and

- Compliance will result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Regulatory Process

  • NRC-approved Code Cases provide an acceptable voluntary alternative to the mandatory ASME B&PV Code provisions.
  • Users of Code Cases are responsible for ensuring it does not conflict with the licensees commitments or regulatory requirements.

ASME Code Case N-883

  • Code Case N-883 - Construction of Items Prior to the Establishment of a Section III, Division 1 Owner

- Approved in RG 1.84 with the following condition:

  • This Code Case may only be used for the construction of items by a holder of a construction permit, operating license, or combined license under 10 CFR Part 50 or Part 52. This Code Case may not be used by a holder of a manufacturing license or standard design approval or by a design certification applicant.

ASME Code Case N-883

  • Code Case N-883 would allow Certificate Holders to construct components prior to the establishment of an Owner.
  • NRC concerned with not being able to provide regulatory oversight of the ASME Certificate Holders manufacturing the components:

- Not consistent with the requirements in Appendix B to 10 CFR Part 50 and in 10 CFR 50.55a for a basic component.

Next Steps

  • NRC working on developing different regulatory approaches to consider incorporation of the premise of Code Case N-883 into the regulatory framework.

Questions and Contact Information Contact Information:

Yamir Diaz-Castillo Phone: 1-301-415-2228 Email: yamir.diaz-castillo@nrc.gov