Technical Specifications ESFAS Startup Feedwater Flow Instrumentation 3.3.11 VEGP Units 3 and 4 3.3.11 - 2 Amendment No. 168 (Unit 3)
Amendment No. 166 (Unit 4)
SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.3.11.1
- NOTE -
This surveillance shall include verification that the time constants are adjusted to within limits.
Perform CHANNEL CALIBRATION in accordance with Setpoint Program.
24 months SR 3.3.11.2 Verify ESF RESPONSE TIME is within limit.