NRCs Methodology to Estimate Fuel Dispersal during a Large Break Loss of Coolant Accident Andy Bielen, James Corson, and Joe Staudenmeier Division of Systems Analysis Office of Nuclear Regulatory Research U.S. Nuclear Regulatory Commission
FFRD as Applied to Plant Calculations 2
How many rods rupture?
What are the cladding temperatures as a function of time through the core? (i.e. not just the hot rod PCT)
Whats the burnup of each ruptured rod?
How much fuel disperses?
What are the consequences of dispersal?
Transport:
Terminal velocity of buoyancy force Pressure Pulse Coolability Dose Chemical Effects GSI-191 Current work: estimating the blue boxes
Plant Calculations: Motivations
- NRC is demonstrating its analysis capabilities
- Selected boundary conditions may not be representative of licensing approaches
- One should not draw conclusions on fuel safety based on this initial analysis
- NRC staff can leverage experience gleaned developing this tool to help prepare for topical report submittals from fuel vendors
- Vendors may use similar approaches to quantify how many high burnup rods burst, how much fuel is released
- Risk-informed approaches may still require assessment of potential FFRD consequences
- Tool could provide reasonable starting point for consequence analysis 3
Overall Approach Goal: estimate mass loss from FFRD during large break loss of coolant accident (LBLOCA)
Approach:
- Polaris/PARCS for core depletion calculations - generate fuel operating histories
- FAST for steady-state fuel performance (FP)
- TRACE for core & system thermal-hydraulics (T/H) during transient of interest at core statepoint of interest
- FAST for transient FP - calculate burst population of HBU fuel rods Burnup distribution + burst characteristics -> RIL FFRD models ->
Estimated mass loss Target demonstration: end of cycle (EOC) of an high burnup (HBU)/extended enrichment (EE) core design (5 wt/o to 8 wt/o enriched fuel) 4
Workflow for Holistic Accident Multi-physics 5
Pre-transient fuel condition :
representative rods per assembly Data: Core/fuel
- design, operating conditions Core depletion simulation:
Polaris/GenPMAXS/PARCS (assembly-based)
Fuel history simulation:
FAST (representative rods per assembly)
Pin power reconstruction Transient simulation:
TRACE (assembly-based T/H, representative fuel rods per assembly)
Fuel history simulation:
FAST (pin-by-pin)
Pin power reconstruction Transient fuel performance: FAST (pin-by-pin resolution)
Transient thermal/hydraulic conditions: assembly-based Pre-transient fuel condition :
pin-by pin RIL FFRD Empirical Models Burnup distribution and burst strains/locations Fuel mass loss to RCS Blue: Assembly-level calculations Orange: Pin-level calculations
Core and Fuel Design Description 6
H G
F E
D C
B A
5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 80 5.95 l 200 5.95 l 200 FEED H-6 FEED N-4 F-4 B-8 FEED K-6 0.0 / 37.2 37.2 / 67.6 0.0 / 37.2 35.1 / 64.6 35.1 / 64.0 35.1 / 65.4 0.0 / 33.5 36.8 / 52.4 5.95 l 200 5.95 l 200 l 24 5.95 l 200 5.95 l 200 l 24 6.20 l 200 5.95 l 200 5.95 l 200 l 20 5.95 l 200 F-8 FEED J-9 FEED F-2 FEED FEED N-9 37.2 / 67.6 0.0 / 34.9 34.1 / 65.4 0.0 / 34.0 32.5 / 63.5 0.0 / 37.9 0.0 / 32.0 37.9 / 52.7 5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 200 l 24 6.20 l 200 5.95 l 104 5.95 l 200 FEED M-10 FEED E-7 FEED B-5 FEED P-12 0.0 / 37.2 35.1 / 66.1 0.0 / 36.8 34.2 / 64.2 0.0 / 34.6 29.6 / 62.9 0.0 / 33.5 55.6 / 67.4 5.95 l 200 5.95 l 200 l 24 5.95 l 200 5.95 l 200 5.95 l 200 5.95 l 200 6.20 l 200 l 8 6.20 l 200 D-3 FEED G-5 D-13 G-2 FEED FEED J-4 35.1 / 64.6 0.0 / 33.9 34.3 / 64.2 35.1 / 63.3 32.0 / 62.6 0.0 / 37.6 0.0 / 29.0 61.1 / 69.9 5.95 l 200 6.20 l 200 5.95 l 200 l 24 5.95 l 200 6.60 l 128 5.95 l 200 5.95 l 200 D-10 P-10 FEED P-9 C-13 FEED N-5 35.1 / 64.0 32.6 / 63.5 0.0 / 34.6 32.1 / 62.7 29.5 / 62.3 0.0 / 34.8 37.4 / 55.3 5.95 l 80 5.95 l 200 6.20 l 200 5.95 l 200 5.95 l 200 6.60 l 156 5.95 l 200 H-14 FEED L-14 FEED FEED FEED R-9 35.1 / 65.4 0.0 / 37.9 29.6 / 62.9 0.0 / 37.6 0.0 / 34.8 0.0 / 28.9 51.9 / 61.8 5.95 l 200 5.95 l 200 l 20 5.95 l 104 6.20 l 200 l 8 5.95 l 200 5.95 l 200 FEED FEED FEED FEED L-3 G-1 0.0 / 33.5 0.0 / 32.0 0.0 / 33.6 0.0 / 29.1 37.4 / 55.3 52.8 / 62.7 5.95 l 200 5.95 l 200 5.95 l 200 6.60 l 156 Enr l IFBA l WABA F-6 J-13 D-2 M-4 PrevCycLoc 36.8 / 52.4 37.9 / 52.8 55.6 / 67.5 62.0 / 71.0 BOC/EOC BU 14 15 8
9 10 11 12 13 Prospective EE/HBU loading for a Westinghouse (W) 4-loop core obtained from DOE NEAMS program 24-month cycle length Feed enrichment 5.95 wt/o to 6.60 wt/o End-of-life assembly burnups >71 GWd/MTU W VANTAGE+ fuel design Early-cycle excess reactivity controlled with integral fuel burnable absorber (IFBA) and wet annular burnable absorber (WABA)
One possible fuel management strategy for HBU/EE Quarter-core representation of core loading pattern for presentation -
modeling is performed in full-core
Steady State Results
- Cycle depletion results generally in good agreement with NEAMS and utility results
- Fuel performance show this is a very aggressive (and probably unrealistic) core design
- Very high fission gas release, rod internal pressure, cladding strain
- Pin-by-pin results provide more clarity about fuel performance trends 7
Linear Heat Generation Rate Fission Gas Release Rod Internal Pressure
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
TRACE Model Description
- Calculations use a 4-loop Westinghouse model
- Model uses cartesian vessel component for the active core
- Each assembly represented by vessel node in XY plane
- 3 heat structures per assembly: representative IFBA, representative non-IFBA, and hot rod
- Several LBLOCA transients with large (i.e.,
cartesian core) model have been run using various input permutations
- Run with TRACE V5.0 patch 7RC3
- 350 s of simulation time took ~5.5 days wall time 9
TRACE PCT vs. Time 10 Axial power distribution sensitivity -
candidate shapes Resulting PCT trends - rough surrogate for overall core heat-up
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
Transient Fuel Performance Results
- Significant fraction of rods burst for all cases
- 64% for base case
- > 75% for Top peak cases
- All others closer to base case
- Most bursts occurred near the top of the rod during reflood
- However, burst timing and location depends strongly on axial power profile
- Burst temperature tended to be low compared to Chapman correlation in NUREG-0630
- Relatively large amount of dispersed fuel based on models in the RIL
- Likely conservative due to conservative models in RIL and potentially conservative predictions of burst 11
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
Base Case Burst Results 12 Burst (red/magenta) vs. non-burst (blue/cyan) rods End of cycle linear heat rate (kW/m)
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
Fuel Dispersal
- Models from Appendix A of RIL 2021-13 used to estimate full-core dispersed mass
- Model C: All fuel in nodes with burnup > 55 GWd/MTU and hoop strain > 3%
- Model A: Fraction of fuel in nodes with burnup > 55 GWd/MTU and strain > 3%
- Fraction = min(1.0, 0.04 * (BU - 55 GWd/MTU))
- Based on mass fraction < 1 mm as function of burnup from SCIP, Halden)
- Models assume:
- Fragments can travel long distance to get to burst opening
- Large burst opening size 13
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
Dispersed Mass Results Base Case Chopped Cosine Power Profile 14
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
Conclusions from Analytical Work
- NRC has developed and demonstrated its WHAM methodology to estimate fuel dispersal
- Experience with our own methods may be useful when supporting future licensing reviews
- This exercise has identified several areas for improvement
- Upgrades to PARCS to improve intra-bundle predictions
- Better modeling of connections between cartesian vessel (core) and cylindrical vessel (upper/lower plena) in TRACE
- Improvements to transient FGR models in FAST
- Additional code validation
- Again, this is only a demonstration 15
BACKUP SLIDES 16
Cycle Depletion Results NRC Results - Polaris/PARCS 17 NEAMS Results - VERA Parameter Utility Simulation NEAMS NRC Maximum fuel rod power (-)
1.49 1.51 1.52 Maximum local pin power (-)
1.76 1.85 1.91 Maximum assembly power (-)
1.39 1.39 1.40 Maximum boron concentration (ppmB) 1568 1586 1573
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.
TRACE Model 18
Comparison to Chapman Correlation 19 Figure 3 of NUREG-0630, showing the Chapman correlation vs. burst test data Burst results from the FAST base case calculations
- Calculations and conclusions are produced for code readiness demonstration purposes only and are not representative of actual licensee designs or analysis.