Urenco USA: Report of Radioactivity in Effluents: Liquid & Air: July 2022 - December 2022
ML23058A252
Person / Time
Site: 07003103
Issue date: 02/27/2023
From:
Louisiana Energy Services, URENCO USA
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML23058A250 List:
References
LES-23-036-NRC
Download: ML23058A252 (1)


Text

URENCO USA: Report of Radioactivity in Effluents: Liquid & Air: July 2022 - December 2022 There were no releases to the public during the reporting period that exceeded regulatory requirements.

Isotopic uranium activities were comparable to pre-operational activities. A dose assessment was not performed because the maximum potential dose directly at the point of gaseous and liquid effluent discharge points was acceptable. The potential maximum dose directly at the discharge points for both liquid and gaseous effluent were shown to be less than 10% of the radionuclide concentration limit.

In liquid effluent, the concentrations of isotopic uranium were below the Minimum Detectable Concentration (MDC) and were less than 10% of values listed in 10 CFR 20, Appendix B, Table 3, Releases to Sewers. Quantity released is calculated if the result equals or exceeds the lower LLD.

Facility LLD is 3.00E-09 µCi/mL.

In gaseous effluent, the gross uranium activities were below the Minimum Detectable Activity (MDA) or were less than 10% of values listed in 10 CFR 20, Appendix B, Table 2, Effluent Concentrations - Col. 1, Class D for U234, U235, and U238. Quantity released is calculated if the result equals or exceeds the MDA.

The concentrations of isotopic uranium in gaseous effluents were either below the Minimum Detectable Concentration (MDC) or were less than 10% of values listed in 10 CFR 20.1301, 10 CFR 20.1302, and 10 CFR 20.1101(d), as described in NRC Regulatory Guide 4.20 Constraint on Releases of Airborne Radioactive Materials to the Environment for Licensees other than Power Reactors dated December 1996. Quantity released is calculated if the result equals or exceeds MDC.

LIST OF TABLES Table No.

Title 1-1 Lift Station 1 Wastewater Effluent - Radionuclides Quarters 3 & 4, 2022 1-2 Separations Building Module-1001 (SBM 1001): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 & 1003-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 & 1005-562-1MA2 Gross Alpha & Beta, and Radionuclides Quarters: 3 & 4, 2022 1-5 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1MA1 & 1100-562-1MA2 - Gross Alpha &

Beta, and Radionuclides: Quarters 3 & 4, 2022 1-6 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 & 1100-562-2MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022

TABLE 1-1 Lift Station 1 Wastewater Effluent - Radionuclides, Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico Radionuclide Sample Date (Date/Time)

Sample Period Total Time (days)

Results (Ci/ml)

Counting Uncertainty (Ci/ml)

Total Flow¹ (gallons/day)

Quantity Released (Ci)

Uranium - 233/234 6.00E-10 1.00E-10 13,000 Result Below LLD Uranium - 235/236 4.00E-11 2.00E-11 13,000 Result Below LLD Uranium - 238 2.00E-10 1.00E-10 13,000 Result Below LLD Uranium - 233/234 6.00E-10 1.00E-10 13,000 Result Below LLD Uranium - 235/236 5.00E-11 2.00E-11 13,000 Result Below LLD Uranium - 238 4.00E-10 1.00E-10 13,000 Result Below LLD

% of Table 3 of Appendix B to 10 CFR 20 Values-Monthly Average Release to Sewars Lift Station 1 - July - December 2022 10/21/2022 10:21 07/01/22 - 12/31/22 183 Result Below LLD Result Below LLD Result Below LLD Lift Station 1 Duplicate - July - December 2022 10/21/2022 10:21 07/01/22 - 12/31/22 183 Result Below LLD Result Below LLD Result Below LLD Notes:

1.

Table 3.4-4 Anticipated Normal Plant Water Consumption from the Environmental Report, Rev. 23, lists Total Personnel Water Use as approximately 13,000 gallons per day.

TABLE 1-2 Separations Building Module-1001 (SBM 1001): Pumped Extract Exhaust Gaseous Effluent Vent System, 1001-562-1MA1 & 1001-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico.

Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)

Sample Period Analyte Gross Result (Ci/ml)

MDA (Ci/ml)

@ 95 CL Instrument Unc (Ci/ml)

Total Vent System Flow (m3)

Quantity Released (Ci)

% of Table 2 of Appendix B to 10 CFR 20 Values 10015621MA1 070522 08/05/22 1230 07/05/22 - 08/05/21 0.00E+00 1.63E-16 0.00E+00 4.15E+05

<MDA

<MDA 10015621MA1 080522 09/08/22 0956 08/05/22 - 09/08/22 1.09E-16 1.48E-16 9.91E-08 4.63E+05

<MDA

<MDA 10015621MA1 090822 10/05/22 1404 09/08/22 - 10/05/22 0.00E+00 1.85E-16 0.00E+00 3.70E+05

<MDA

<MDA 10015621MA1 100522 11/07/22 1402 10/05/22 - 11/07/22 0.00E+00 1.52E-16 0.00E+00 4.42E+05

<MDA

<MDA 10015621MA1 110722 12/08/22 1053 11/07/22 - 12/08/22 5.83E-17 1.62E-16 6.76E-08 4.15E+05

<MDA

<MDA 10015621MA1 120822 01/03/23 1516 12/08/22 - 01/03/23 7.18E-17 2.00E-16 6.76E-08 3.27E+05

<MDA

<MDA 10015621MA1 070522 08/05/22 1230 07/05/22 - 08/05/21 5.35E-15 3.15E-15 1.55E-06 4.15E+05 2.22E-09 0.18%

10015621MA1 080522 09/08/22 0956 08/05/22 - 09/08/22 6.40E-15 2.85E-15 1.78E-06 4.63E+05 2.96E-09 0.21%

10015621MA1 090822 10/05/22 1404 09/08/22 - 10/05/22 6.59E-15 3.58E-15 1.59E-06 3.70E+05 2.44E-09 0.22%

10015621MA1 100522 11/07/22 1402 10/05/22 - 11/07/22 4.80E-15 2.97E-15 1.56E-06 4.42E+05 2.12E-09 0.16%

10015621MA1 110722 12/08/22 1053 11/07/22 - 12/08/22 3.60E-15 3.17E-15 1.35E-06 4.15E+05 1.50E-09 0.12%

10015621MA1 120822 01/03/23 1516 12/08/22 - 01/03/23 3.94E-15 3.91E-15 1.31E-06 3.27E+05 1.29E-09 0.13%

10015621MA2 070522 08/05/22 1225 07/05/22 - 08/05/22

-2.99E-17 1.44E-16 1.44E-10 4.53E+05

<MDA

<MDA 10015621MA2 080522 09/08/22 1005 08/05/22 - 09/08/22 0.00E+00 1.37E-16 0.00E+00 5.01E+05

<MDA

<MDA 10015621MA2 090822 10/05/22 1354 09/08/22 - 10/05/22 0.00E+00 1.72E-16 0.00E+00 3.99E+05

<MDA

<MDA 10015621MA2 100522 11/07/22 1409 10/05/22 - 11/07/22 1.53E-16 1.39E-16 1.22E-07 4.79E+05 7.35E-11 0.005%

10015621MA2 110722 12/08/22 1058 11/07/22 - 12/08/22 6.56E-17 1.83E-16 6.76E-08 4.58E+05

<MDA

<MDA 10015621MA2 120822 01/03/23 1520 12/08/22 - 01/03/23 6.26E-17 1.74E-16 6.76E-08 3.91E+05

<MDA

<MDA 10015621MA2 070522 08/05/22 1225 07/05/22 - 08/05/22 4.93E-15 2.79E-15 1.70E-06 4.53E+05 2.23E-09 0.16%

10015621MA2 080522 09/08/22 1005 08/05/22 - 09/08/22 3.37E-15 2.64E-15 1.41E-06 5.01E+05 1.69E-09 0.11%

10015621MA2 090822 10/05/22 1354 09/08/22 - 10/05/22 6.82E-15 3.32E-15 1.66E-06 3.99E+05 2.72E-09 0.23%

10015621MA2 100522 11/07/22 1409 10/05/22 - 11/07/22 5.16E-15 2.73E-15 1.57E-06 4.79E+05 2.47E-09 0.17%

10015621MA2 110722 12/08/22 1058 11/07/22 - 12/08/22 5.41E-15 3.57E-15 1.47E-06 4.58E+05 2.48E-09 0.18%

10015621MA2 120822 01/03/23 1520 12/08/22 - 01/03/23 5.37E-15 3.41E-15 1.49E-06 3.91E+05 2.10E-09 0.18%

Gross Beta Gross Alpha Gross Beta Gross Alpha 1001-562-1MA1 1001-562-1MA2 Radionuclide Sample Date (Off Date)

Sample Period Result (Ci/ml) 2 sigma (Ci/ml) 1 sigma (Ci/ml)

MDC (Ci/ml)

Total Flow (m3)

Quantity Released (Ci)

Uranium-233/234 3rd Qtr 2022 7.72E-17 3.25E-17 3.29E-17 1.41E-17 1.25E+06 0.00 Uranium-235/236 3rd Qtr 2022 1.25E-17 1.64E-17 1.64E-17 2.50E-17 1.25E+06 Result Below MDC Uranium-238 3rd Qtr 2022 5.62E-17 2.77E-17 2.80E-17 1.61E-17 1.25E+06 0.00 Uranium-233/234 4th Qtr 2022 2.37E-16 8.19E-17 8.37E-17 4.06E-17 1.18E+06 0.00 Uranium-235/236 4th Qtr 2022 1.67E-17 2.84E-17 2.84E-17 5.00E-17 1.18E+06 Result Below MDC Uranium-238 4th Qtr 2022 2.09E-16 7.68E-17 7.83E-17 4.05E-17 1.18E+06 0.00 Uranium-233/234 3rd Qtr 2022 7.39E-17 2.97E-17 3.01E-17 1.52E-17 1.35E+06 0.00 Uranium-235/236 3rd Qtr 2022 2.36E-18 7.21E-18 7.22E-18 1.71E-17 1.35E+06 Result Below MDC Uranium-238 3rd Qtr 2022 5.50E-17 2.58E-17 2.61E-17 1.74E-17 1.35E+06 0.00 Uranium-233/234 4th Qtr 2022 2.00E-16 7.40E-17 7.54E-17 2.80E-17 1.33E+06 0.00 Uranium-235/236 4th Qtr 2022 3.17E-17 3.27E-17 3.28E-17 3.46E-17 1.33E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.44E-16 6.29E-17 6.37E-17 3.52E-17 1.33E+06 0.00 1/3/2023 10/5/22 - 1/3/23 0.007%

Result Below MDC 0.005%

Sample ID: 1001-562-1MA2 10/5/2022 7/5/22 - 10/5/22 0.002%

Result Below MDC 0.002%

7/5/22 - 10/5/22 0.003%

Result Below MDC 0.002%

1/3/2023 10/5/22 - 1/3/23 0.008%

Result Below MDC 0.007%

% of Table 2 of Appendix B to 10 CFR 20 Values Sample ID: 1001-562-1MA1 10/5/2022 Notes: None

TABLE 1-3 Separations Building Module-1003 (SBM 1003): Pumped Extract Exhaust Gaseous Effluent Vent System, 1003-562-1MA1 &

1003-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)

Sample Period Analyte Gross Result (Ci/ml)

MDA (Ci/ml)

@ 95 CL Instrument Unc (Ci/ml)

Total Vent System Flow (m3)

Quantity Released (Ci)

% of Table 2 of Appendix B to 10 CFR 20 Values 10035621MA1 071122 08/05/22 1313 07/11/22 - 08/05/22 1.16E-16 1.56E-16 9.91E-08 3.83E+05

<MDA

<MDA 10035621MA1 080522 09/05/22 1050 08/05/22 - 09/08/22 1.42E-16 1.27E-16 1.22E-07 5.22E+05 7.43E-11 0.00%

10035621MA1 090822 10/05/22 1420 09/08/22 - 10/05/22 6.01E-17 1.58E-16 7.21E-08 4.37E+05

<MDA

<MDA 10035621MA1 100522 11/08/22 1930 10/05/22 - 11/08/22 9.15E-17 1.23E-16 9.91E-08 5.38E+05

<MDA

<MDA 10035621MA1 110822 12/08/22 1116 11/08/22 - 12/08/22 0.00E+00 1.46E-16 0.00E+00 4.74E+05

<MDA

<MDA 10035621MA1 120822 01/03/23 1531 12/08/22 - 01/03/23 0.00E+00 1.59E-16 0.00E+00 4.18E+05

<MDA

<MDA 10035621MA1 071122 08/05/22 1313 07/11/22 - 08/05/22 3.42E-15 3.02E-15 1.37E-06 3.83E+05 1.31E-09 0.11%

10035621MA1 080522 09/05/22 1050 08/05/22 - 09/08/22 5.21E-15 2.45E-15 1.68E-06 5.22E+05 2.72E-09 0.17%

10035621MA1 090822 10/05/22 1420 09/08/22 - 10/05/22 4.38E-15 3.04E-15 1.64E-06 4.37E+05 1.91E-09 0.15%

10035621MA1 100522 11/08/22 1930 10/05/22 - 11/08/22 4.10E-15 2.41E-15 1.52E-06 5.38E+05 2.21E-09 0.14%

10035621MA1 110822 12/08/22 1116 11/08/22 - 12/08/22 5.40E-15 2.85E-15 1.57E-06 4.74E+05 2.56E-09 0.180%

10035621MA1 120822 01/03/23 1531 12/08/22 - 01/03/23 3.35E-15 3.12E-15 1.33E-06 4.18E+05 1.40E-09 0.11%

10035621MA2 070522 08/05/22 1330 07/11/22 - 08/05/22 8.87E-16 2.35E-15 7.21E-08 4.18E+05

<MDA

<MDA 10035621MA2 080522 09/08/22 1059 08/05/22 - 09/08/22 1.36E-16 1.83E-16 9.91E-08 5.71E+05

<MDA

<MDA 10035621MA2 090822 10/05/22 1429 09/08/22 - 10/05/22 0.00E+00 2.21E-16 0.00E+00 4.79E+05

<MDA

<MDA 10035621MA2 100522 11/08/22 1937 10/05/22 - 11/08/22 2.63E-16 1.77E-16 1.40E-07 5.97E+05 1.57E-10 0.009%

10035621MA2 110822 12/08/22 1123 11/08/22 - 12/08/22 0.00E+00 1.99E-16 0.00E+00 5.20E+05

<MDA

<MDA 10035621MA2 120822 01/03/23 1538 12/08/22 - 01/03/23 0.00E+00 2.37E-16 0.00E+00 4.63E+05

<MDA

<MDA 10035621MA2 070522 08/05/22 1330 07/11/22 - 08/05/22 4.83E-14 4.55E-14 1.34E-06 4.18E+05 2.02E-08 1.611%

10035621MA2 080522 09/08/22 1059 08/05/22 - 09/08/22 7.94E-15 3.54E-15 1.77E-06 5.71E+05 4.53E-09 0.265%

10035621MA2 090822 10/05/22 1429 09/08/22 - 10/05/22 6.34E-15 4.26E-15 1.49E-06 4.79E+05 3.04E-09 0.211%

10035621MA2 100522 11/08/22 1937 10/05/22 - 11/08/22 5.47E-15 3.47E-15 1.49E-06 5.97E+05 3.27E-09 0.182%

10035621MA2 110822 12/08/22 1123 11/08/22 - 12/08/22 6.15E-15 3.90E-15 1.49E-06 5.20E+05 3.20E-09 0.205%

10035621MA2 120822 01/03/23 1538 12/08/22 - 01/03/23 9.06E-15 4.63E-15 1.59E-06 4.63E+05 4.20E-09 0.302%

1003-562-1MA1 1003-562-1MA2 Gross Alpha Gross Beta Gross Alpha Gross Beta Radionuclide Sample Date (Off Date)

Sample Period Result (Ci/ml) 2 sigma (Ci/ml) 1 sigma (Ci/ml)

MDC (Ci/ml)

Total Flow (m3)

Quantity Released (Ci)

Uranium-233/234 3rd Qtr 2022 1.35E-16 4.17E-17 4.28E-17 1.47E-17 1.34E+06 0.00 Uranium-235/236 3rd Qtr 2022 1.08E-17 1.30E-17 1.30E-17 1.59E-17 1.34E+06 Result Below MDC Uranium-238 3rd Qtr 2022 1.08E-16 3.73E-17 3.81E-17 1.85E-17 1.34E+06 0.00 Uranium-233/234 4th Qtr 2022 1.41E-16 6.45E-17 6.53E-17 4.20E-17 1.43E+06 0.00 Uranium-235/236 4th Qtr 2022 7.19E-18 1.72E-17 1.72E-17 3.62E-17 1.43E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.66E-16 6.90E-17 7.00E-17 3.35E-17 1.43E+06 0.00 Uranium-233/234 3rd Qtr 2022 1.03E-16 4.70E-17 4.76E-17 3.42E-17 1.47E+06 0.00 Uranium-235/236 3rd Qtr 2022 2.36E-17 2.43E-17 2.44E-17 2.57E-17 1.47E+06 Result Below MDC Uranium-238 3rd Qtr 2022 1.03E-16 4.57E-17 4.63E-17 2.38E-17 1.47E+06 0.00 Uranium-233/234 4th Qtr 2022 1.49E-16 7.08E-17 7.16E-17 3.49E-17 1.58E+06 0.00 Uranium-235/236 4th Qtr 2022 3.10E-17 4.06E-17 4.06E-17 6.19E-17 1.58E+06 Result Below MDC Uranium-238 4th Qtr 2022 2.26E-16 8.88E-17 9.01E-17 5.01E-17 1.58E+06 0.00 10/5/2022 7/11/22 - 10/5/22 0.003%

Result Below MDC 0.003%

1/3/2023 10/5/22 - 1/3/23 0.005%

Result Below MDC 0.008%

1/3/2023 10/5/22 - 1/3/23 0.005%

Result Below MDC 0.006%

1003-562-1MA2

% of Table 2 of Appendix B to 10 CFR 20 Values 1003-562-1MA1 10/5/2022 7/11/22 - 10/5/22 0.005%

Result Below MDC 0.004%

Notes: None

TABLE 1-4 Separations Building Module-1005 (SBM 1005): Pumped Extract Exhaust Gaseous Effluent Vent System, 1005-562-1MA1 &

1005-562-1MA2 Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)

Sample Period Analyte Gross Result (Ci/ml)

MDA (Ci/ml)

@ 95 CL Instrument Unc (Ci/ml)

Total Vent System Flow (m3)

Quantity Released (Ci)

% of Table 2 of Appendix B to 10 CFR 20 Values 10055621MA1 070522 08/05/22 1332 07/05/22 - 08/05/22 0.00E+00 1.78E-16 0.00E+00 9.11E+05

<MDA

<MDA 10055621MA1 080522 09/08/22 1110 08/05/22 - 09/08/22 6.16E-17 1.62E-16 7.21E-08 1.04E+06

<MDA

<MDA 10055621MA1 090822 10/05/22 1447 09/08/21 - 10/05/22 0.00E+00 1.99E-16 0.00E+00 9.51E+05

<MDA

<MDA 10055621MA1 100522 11/08/22 1947 10/05/22 - 11/08/22 0.00E+00 1.58E-16 0.00E+00 9.75E+05

<MDA

<MDA 10055621MA1 110822 12/08/22 1132 11/08/22 - 12/08/22 6.63E-17 1.84E-16 6.76E-08 8.01E+05

<MDA

<MDA 10055621MA1 120822 01/03/23 1544 12/08/22 - 01/03/23 1.53E-16 2.05E-16 9.91E-08 6.91E+05

<MDA

<MDA 10055621MA1 070522 08/05/22 1332 07/05/22 - 08/05/22 6.09E-15 3.44E-15 1.57E-06 9.11E+05 5.55E-09 0.203%

10055621MA1 080522 09/08/22 1110 08/05/22 - 09/08/22 3.76E-15 3.12E-15 1.39E-06 1.04E+06 3.92E-09 0.125%

10055621MA1 090822 10/05/22 1447 09/08/21 - 10/05/22 5.98E-15 3.83E-15 1.51E-06 9.51E+05 5.68E-09 0.199%

10055621MA1 100522 11/08/22 1947 10/05/22 - 11/08/22 3.83E-15 3.09E-15 1.46E-06 9.75E+05 3.74E-09 0.128%

10055621MA1 110822 12/08/22 1132 11/08/22 - 12/08/22 8.42E-15 3.61E-15 1.69E-06 8.01E+05 6.74E-09 0.281%

10055621MA1 120822 01/03/23 1544 12/08/22 - 01/03/23 8.37E-15 4.02E-15 1.63E-06 6.91E+05 5.79E-09 0.279%

10055621MA2 070522 08/05/22 1335 07/05/22 - 08/05/22 1.21E-16 1.63E-16 9.91E-08 9.43E+05

<MDA

<MDA 10055621MA2 080522 09/08/22 1113 08/05/22 - 09/08/22 1.64E-16 1.47E-16 1.22E-07 1.10E+06 1.80E-10 0.005%

10055621MA2 090822 10/05/22 1450 09/08/22 - 10/05/22 7.00E-17 1.83E-16 7.21E-08 9.86E+05

<MDA

<MDA 10055621MA2 100522 11/08/22 1952 10/05/22 - 11/08/22 1.13E-16 1.52E-16 9.91E-08 9.99E+05

<MDA

<MDA 10055621MA2 110822 12/08/22 1135 11/08/22 - 12/08/22 0.00E+00 1.79E-16 0.00E+00 8.17E+05

<MDA

<MDA 10055621MA2 120822 01/03/23 1548 12/08/22 - 01/03/23 7.38E-17 2.05E-16 6.76E-08 7.04E+05

<MDA

<MDA 10055621MA2 070522 08/05/22 1335 07/05/22 - 08/05/22 4.91E-15 3.15E-15 1.51E-06 9.43E+05 4.62E-09 0.164%

10055621MA2 080522 09/08/22 1113 08/05/22 - 09/08/22 4.21E-15 2.83E-15 1.49E-06 1.10E+06 4.61E-09 0.140%

10055621MA2 090822 10/05/22 1450 09/08/22 - 10/05/22 6.03E-15 3.54E-15 1.55E-06 9.86E+05 5.94E-09 0.201%

10055621MA2 100522 11/08/22 1952 10/05/22 - 11/08/22 3.93E-15 2.97E-15 1.41E-06 9.99E+05 3.92E-09 0.131%

10055621MA2 110822 12/08/22 1135 11/08/22 - 12/08/22 5.74E-15 3.50E-15 1.50E-06 8.17E+05 4.69E-09 0.191%

10055621MA2 120822 01/03/23 1548 12/08/22 - 01/03/23 8.86E-15 4.02E-15 1.66E-06 7.04E+05 6.24E-09 0.295%

Gross Alpha Gross Beta Gross Alpha 1005-562-1MA2 Gross Beta 1005-562-1MA1 Radionuclide Sample Date (Off Date)

Sample Period Result (Ci/ml) 2 sigma (Ci/ml) 1 sigma (Ci/ml)

MDC (Ci/ml)

Total Flow (m3)

Quantity Released (Ci)

Uranium-233/234 3rd Qtr 2022 6.75E-17 4.19E-17 4.21E-17 3.97E-17 2.90E+06 0.00 Uranium-235/236 3rd Qtr 2022 1.19E-17 2.01E-17 2.02E-17 3.42E-17 2.90E+06 Result Below MDC Uranium-238 3rd Qtr 2022 6.74E-17 3.99E-17 4.02E-17 2.77E-17 2.90E+06 0.00 Uranium-233/234 4th Qtr 2022 1.02E-16 6.43E-17 6.47E-17 5.12E-17 2.47E+06 0.00 Uranium-235/236 4th Qtr 2022

-6.14E-18 2.46E-17 2.46E-17 6.31E-17 2.47E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.20E-16 7.00E-17 7.05E-17 5.49E-17 2.47E+06 0.00 Uranium-233/234 3rd Qtr 2022 7.42E-17 3.37E-17 3.42E-17 1.80E-17 3.02E+06 0.00 Uranium-235/236 3rd Qtr 2022

-7.91E-19 9.25E-18 9.25E-18 1.94E-17 3.02E+06 Result Below MDC Uranium-238 3rd Qtr 2022 7.84E-17 3.45E-17 3.50E-17 1.57E-17 3.02E+06 0.00 Uranium-233/234 4th Qtr 2022 1.73E-16 7.28E-17 7.38E-17 4.18E-17 2.52E+06 0.00 Uranium-235/236 4th Qtr 2022 2.12E-17 3.17E-17 3.17E-17 5.16E-17 2.52E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.44E-16 6.61E-17 6.69E-17 3.88E-17 2.52E+06 0.00 10/5/2022 7/5/22 - 10/5/22 0.002%

Result Below MDC 0.003%

1/3/2023 10/5/22 - 1/3/23 0.006%

Result Below MDC 0.005%

1/3/2023 10/5/22 - 1/3/23 0.003%

Result Below MDC 0.004%

1005-562-1MA2

% of Table 2 of Appendix B to 10 CFR 20 Values 1005-562-1MA1 10/5/2022 7/5/22 - 10/5/22 0.002%

Result Below MDC 0.002%

Notes: None

TABLE 1-5 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Local Extract Exhaust Gaseous Effluent Vent System, 1100-562-1MA1 &

1100-562-1MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)

Sample Period Analyte Gross Result (Ci/ml)

MDA (Ci/ml)

@ 95 CL Instrument Unc (Ci/ml)

Total Vent System Flow (m3)

Quantity Released (Ci)

% of Table 2 of Appendix B to 10 CFR 20 Values 11005621MA1 070522 08/05/22 1249 07/05/22 - 8/05/22 7.14E-17 1.87E-16 7.21E-08 1.07E+06

<MDA

<MDA 11005621MA1 080522 09/08/22 1026 08/05/22 - 09/08/22 5.72E-17 1.50E-16 7.21E-08 1.17E+06

<MDA

<MDA 11005621MA1 090822 10/05/22 1511 09/08/22 - 10/05/22 8.07E-17 2.12E-16 7.21E-08 4.34E+05

<MDA

<MDA 11005621MA1 100522 11/08/22 1903 10/05/22 - 11/08/22 1.45E-16 1.31E-16 1.22E-07 1.16E+06 1.68E-10 0.005%

11005621MA1 110822 12/08/22 1146 11/08/22 - 12/08/22 1.56E-16 2.10E-16 9.91E-08 2.97E+04

<MDA

<MDA 11005621MA1 120822 01/03/23 1558 12/08/22 - 01/03/23

-4.82E-17 2.31E-16 1.34E-10 1.96E+03

<MDA

<MDA 11005621MA1 070522 08/05/22 1249 07/05/22 - 8/05/22 5.63E-15 3.61E-15 1.51E-06 1.07E+06 6.05E-09 0.188%

11005621MA1 080522 09/08/22 1026 08/05/22 - 09/08/22 5.95E-15 2.90E-15 1.66E-06 1.17E+06 6.95E-09 0.198%

11005621MA1 090822 10/05/22 1511 09/08/22 - 10/05/22 5.98E-15 4.09E-15 1.55E-06 4.34E+05 2.59E-09 0.199%

11005621MA1 100522 11/08/22 1903 10/05/22 - 11/08/22 3.90E-15 2.57E-15 1.47E-06 1.16E+06 4.53E-09 0.130%

11005621MA1 110822 12/08/22 1146 11/08/22 - 12/08/22 4.92E-15 4.10E-15 1.37E-06 2.97E+04 1.46E-10 0.164%

11005621MA1 120822 01/03/23 1558 12/08/22 - 01/03/23 6.27E-15 4.52E-15 1.55E-06 1.96E+03 1.23E-11 0.209%

11005621MA2 070522 08/05/22 1251 07/05/22 - 08/05/22 1.65E-16 2.23E-16 9.91E-08 2.95E+05

<MDA

<MDA 11005621MA2 080522¹ 09/08/22 1029 08/05/22 - 09/08/22 0.00E+00 2.04E-16 0.00E+00 1.17E+06

<MDA

<MDA 11005621MA2 090822 10/05/22 1528 09/08/22 - 10/05/22 4.51E-16 4.02E-16 1.22E-07 3.46E+04 1.56E-11 0.015%

11005621MA2 100522 11/08/22 1907 10/05/22 - 11/08/22 1.03E-16 1.38E-16 9.91E-08 8.87E+05

<MDA

<MDA 11005621MA2 110822 12/08/22 1149 11/08/22 - 12/08/22 5.68E-17 1.58E-16 6.76E-08 7.87E+05

<MDA

<MDA 11005621MA2 120822 01/03/23 1602 12/08/22 - 01/03/23 6.44E-17 1.79E-16 6.76E-08 6.86E+05

<MDA

<MDA 11005621MA2 070522 08/05/22 1251 07/05/22 - 08/05/22 8.54E-15 4.30E-15 1.64E-06 2.95E+05 2.52E-09 0.285%

11005621MA2 080522¹ 09/08/22 1029 08/05/22 - 09/08/22 7.26E-15 3.94E-15 1.59E-06 1.17E+06 8.48E-09 0.242%

11005621MA2 090822 10/05/22 1528 09/08/22 - 10/05/22 1.49E-14 7.77E-15 1.62E-06 3.46E+04 5.13E-10 0.495%

11005621MA2 100522 11/08/22 1907 10/05/22 - 11/08/22 3.41E-15 2.71E-15 1.39E-06 8.87E+05 3.02E-09 0.114%

11005621MA2 110822 12/08/22 1149 11/08/22 - 12/08/22 6.04E-15 3.09E-15 1.59E-06 7.87E+05 4.76E-09 0.201%

11005621MA2 120822 01/03/23 1602 12/08/22 - 01/03/23 4.20E-15 3.50E-15 1.37E-06 6.86E+05 2.88E-09 0.140%

1100-562-1MA1 Gross Beta Gross Alpha 1100-562-1MA2 Gross Alpha Gross Beta Radionuclide Sample Date (Off Date)

Sample Period Result (Ci/ml) 2 sigma (Ci/ml) 1 sigma (Ci/ml)

MDC (Ci/ml)

Total Flow (m3)

Quantity Released (Ci)

Uranium-233/234 3rd Qtr 2022 7.06E-17 4.01E-17 4.04E-17 2.67E-17 2.68E+06 0.00 Uranium-235/236 3rd Qtr 2022 1.14E-17 1.94E-17 1.94E-17 3.29E-17 2.68E+06 Result Below MDC Uranium-238 3rd Qtr 2022 4.90E-17 3.51E-17 3.53E-17 3.67E-17 2.68E+06 0.00 Uranium-233/234 4th Qtr 2022 1.59E-16 7.29E-17 7.38E-17 4.28E-17 1.19E+06 0.00 Uranium-235/236 4th Qtr 2022 3.34E-17 4.01E-17 4.01E-17 5.67E-17 1.19E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.94E-16 7.99E-17 8.11E-17 3.39E-17 1.19E+06 0.00 Uranium-233/234 3rd Qtr 2022 1.17E-16 5.42E-17 5.48E-17 3.41E-17 1.50E+06 0.00 Uranium-235/236 3rd Qtr 2022 1.99E-17 2.56E-17 2.57E-17 3.57E-17 1.50E+06 Result Below MDC Uranium-238 3rd Qtr 2022 9.45E-17 4.98E-17 5.03E-17 4.14E-17 1.50E+06 0.00 Uranium-233/234 4th Qtr 2022 1.59E-16 7.22E-17 7.31E-17 5.05E-17 2.36E+06 0.00 Uranium-235/236 4th Qtr 2022 2.51E-17 3.25E-17 3.25E-17 4.52E-17 2.36E+06 Result Below MDC Uranium-238 4th Qtr 2022 1.35E-16 6.68E-17 6.75E-17 5.24E-17 2.36E+06 0.00 1/3/2023 10/5/22 - 1/3/23 0.005%

Result Below MDC 0.005%

1100-562-1MA2 10/5/2022 7/5/22 - 10/5/22 0.004%

Result Below MDC 0.003%

% of Table 2 of Appendix B to 10 CFR 20 Values 1100-562-1MA1 10/5/2022 7/5/22 - 10/5/22 0.002%

Result Below MDC 0.002%

1/3/2023 10/5/22 - 1/3/23 0.005%

Result Below MDC 0.006%

Notes:

1.

11005621MA2 080522 total vent system flow collected from redundant monitor (1100-562-1MA1) due to totalization issue on 1100-562-1MA2

TABLE 1-6 Cylinder Receipt and Dispatch Building-1100 (CRDB 1100): Fume Hood Exhaust Gaseous Effluent Vent System, 1100-562-2MA1 &

1100-562-2MA2, Gross Alpha & Beta, and Radionuclides: Quarters 3 & 4, 2022 URENCO USA Lea County, New Mexico Sample ID (Functional Loc. / On Date Sample Date (Off Date/Time)

Sample Period Analyte Gross Result (Ci/ml)

MDA (Ci/ml)

@ 95 CL Instrument Unc (Ci/ml)

Total Vent System Flow (m3)

Quantity Released (Ci)

% of Table 2 of Appendix B to 10 CFR 20 Values 11005622MA1 070522 08/05/22 1255 07/05/22 - 08/05/22 1.20E-16 1.62E-16 9.91E-08 3.19E+07

<MDA

<MDA 11005622MA1 080522 09/08/22 1032 08/05/22 - 09/08/22 1.58E-16 1.41E-16 1.22E-07 3.46E+07 5.47E-09 0.005%

11005622MA1 090822 10/05/22 1501 09/08/22 - 10/05/22 7.95E-16 1.95E-16 2.34E-07 2.76E+07 2.19E-08 0.026%

11005622MA1 100522 11/08/22 1913 10/05/22 - 11/08/22 5.37E-17 1.49E-16 6.76E-08 3.43E+07

<MDA

<MDA 11005622MA1 110822 12/08/22 1153 11/08/22 - 12/08/22 6.26E-17 1.74E-16 6.76E-08 2.92E+07

<MDA

<MDA 11005622MA1 120822 01/03/23 1605 12/08/22 - 01/03/23 3.66E-16 1.98E-16 1.58E-07 2.65E+07 9.70E-09 0.012%

11005622MA1 070522 08/05/22 1255 07/05/22 - 08/05/22 8.18E-15 3.12E-15 1.81E-06 3.19E+07 2.61E-07 0.273%

11005622MA1 080522 09/08/22 1032 08/05/22 - 09/08/22 5.21E-15 2.72E-15 1.62E-06 3.46E+07 1.80E-07 0.174%

11005622MA1 090822 10/05/22 1501 09/08/22 - 10/05/22 1.15E-14 3.77E-15 1.92E-06 2.76E+07 3.16E-07 0.382%

11005622MA1 100522 11/08/22 1913 10/05/22 - 11/08/22 3.87E-15 2.92E-15 1.41E-06 3.43E+07 1.33E-07 0.129%

11005622MA1 110822 12/08/22 1153 11/08/22 - 12/08/22 5.16E-15 3.41E-15 1.47E-06 2.92E+07 1.51E-07 0.172%

11005622MA1 120822 01/03/23 1605 12/08/22 - 01/03/23 3.84E-15 3.88E-15 1.39E-06 2.65E+07

<MDA

<MDA 11005622MA2 070522 08/05/22 1300 07/05/22 - 08/05/22 9.74E-16 2.92E-16 2.12E-07 7.23E+02 7.04E-13 0.032%

11005622MA2 080522 09/08/22 1035 08/05/22 - 09/08/22 3.46E-16 2.34E-16 1.40E-07 3.51E+07 1.21E-08 0.012%

11005622MA2 090822 10/05/22 1503 09/08/22 - 10/05/22 7.87E-16 3.03E-16 1.85E-07 2.84E+07 2.23E-08 0.026%

11005622MA2 100522 11/08/22 1916 10/05/22 - 11/08/22 7.92E-17 2.20E-16 6.76E-08 3.56E+07

<MDA

<MDA 11005622MA2 110822 12/08/22 1158 11/08/22 - 12/08/22 1.97E-16 2.65E-16 9.91E-08 3.08E+07

<MDA

<MDA 11005622MA2 120822 01/03/23 1606 12/08/22 - 01/03/23 6.65E-16 2.98E-16 1.71E-07 2.73E+07 1.82E-08 0.022%

11005622MA2 070522 08/05/22 1300 07/05/22 - 08/05/22 1.40E-14 5.63E-15 1.77E-06 7.23E+02 1.01E-11 0.466%

11005622MA2 080522 09/08/22 1035 08/05/22 - 09/08/22 8.66E-15 4.53E-15 1.62E-06 3.51E+07 3.04E-07 0.289%

11005622MA2 090822 10/05/22 1503 09/08/22 - 10/05/22 1.52E-14 5.85E-15 1.88E-06 2.84E+07 4.32E-07 0.507%

11005622MA2 100522 11/08/22 1916 10/05/22 - 11/08/22 4.07E-15 4.31E-15 1.29E-06 3.56E+07

<MDA

<MDA 11005622MA2 110822 12/08/22 1158 11/08/22 - 12/08/22 8.84E-15 5.19E-15 1.52E-06 3.08E+07 2.72E-07 0.295%

11005622MA2 120822 01/03/23 1606 12/08/22 - 01/03/23 1.31E-14 5.84E-15 1.73E-06 2.73E+07 3.59E-07 0.438%

Gross Alpha Gross Beta Gross Alpha 1100-562-2MA1 1100-562-2MA2 Gross Beta Radionuclide Sample Date (Off Date)

Sample Period Result (Ci/ml) 2 sigma (Ci/ml) 1 sigma (Ci/ml)

MDC (Ci/ml)

Total Flow (m3)

Quantity Released (Ci)

Uranium-233/234 3rd Qtr 2022 1.16E-16 4.84E-17 4.91E-17 2.35E-17 9.40E+07 0.00 Uranium-235/236 3rd Qtr 2022 3.99E-18 1.22E-17 1.22E-17 2.89E-17 9.40E+07 Result Below MDC Uranium-238 3rd Qtr 2022 1.26E-16 5.04E-17 5.12E-17 2.04E-17 9.40E+07 0.00 Uranium-233/234 4th Qtr 2022 2.81E-16 8.91E-17 9.14E-17 3.55E-17 9.00E+07 0.00 Uranium-235/236 4th Qtr 2022 4.16E-17 4.08E-17 4.09E-17 5.27E-17 9.00E+07 Result Below MDC Uranium-238 4th Qtr 2022 2.43E-16 8.32E-17 8.50E-17 4.26E-17 9.00E+07 0.00 Uranium-233/234 3rd Qtr 2022 1.90E-16 7.28E-17 7.41E-17 2.85E-17 6.35E+07 0.00 Uranium-235/236 3rd Qtr 2022 4.21E-17 4.06E-17 4.07E-17 5.05E-17 6.35E+07 Result Below MDC Uranium-238 3rd Qtr 2022 2.10E-16 7.67E-17 7.82E-17 2.84E-17 6.35E+07 0.00 Uranium-233/234 4th Qtr 2022 3.27E-16 1.39E-16 1.41E-16 1.25E-16 9.37E+07 0.00 Uranium-235/236 4th Qtr 2022

-1.32E-17 3.41E-17 3.42E-17 1.15E-16 9.37E+07 Result Below MDC Uranium-238 4th Qtr 2022 2.53E-16 1.16E-16 1.17E-16 8.41E-17 9.37E+07 0.00 1/3/2023 10/5/22 - 1/3/23 0.011%

Result Below MDC 0.008%

1100-562-2MA2 10/5/2022 7/5/22 - 10/5/22 0.006%

Result Below MDC 0.007%

1/3/2023 10/5/22 - 1/3/23 0.009%

Result Below MDC 0.008%

% of Table 2 of Appendix B to 10 CFR 20 Values 1100-562-2MA1 10/5/2022 7/5/22 - 10/5/22 0.004%

Result Below MDC 0.004%

Notes: None