Text
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Mr. Anthony J. Schoedel, Manager Advanced Reactors Licensing Engineering Westinghouse Electric Company 1000 Westinghouse Drive Cranberry Township, PA 16066
SUBJECT:
WESTINGHOUSE ELECTRIC COMPANY - U.S. NUCLEAR REGULATORY COMMISSION FEEDBACK REGARDING EVINCITM WHITE PAPER EVR-PGD-OP-002 (EPID NO.: L-2022-LRO-0041)
Dear Mr. Schoedel:
By letter dated October 27, 2022, (Agencywide Documents Access and Management System Accession No. ML22300A108) Westinghouse Electric Company (Westinghouse), submitted for the U.S. Nuclear Regulatory Commission (NRC) staffs review, EVR-PGD-OP-002, Operations and Remote Monitoring. This white paper describes a proposed aspect of the eVinci micro-reactor for which Westinghouse desires to have pre-application interactions. The NRC staff was asked to perform a review of this paper and provide written feedback. The NRC staff completed its review of the white paper and the enclosure to this letter provides the NRC staffs detailed observations for Westinghouse to consider.
The Enclosure to this letter contains proprietary information.
When separated from the Enclosure, this document is DECONTROLLED.
February 25, 2023
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION A. Schoedel 2
If you have questions regarding this matter, please contact Donna Williams at (301) 415-1322 or via email at Donna.Williams@nrc.gov.
Sincerely, William T. Jessup, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 999902079
Enclosure:
as stated Signed by Jessup, William on 02/25/23
Pkg: ML23037A907 Letter: ML23037A910
Enclosure:
ML23037A911 (Proprietary)
NRR-106 OFFICE NRR/DANU/UAL1/PM NRR/DRO/IOLB/BC NRR/DANU/UAL1/BC NAME DWilliams LNist WJessup DATE 2/6/2023 2/24/2023 2/25/2023