ML23030A661

From kanterella
Jump to navigation Jump to search

X Energy, LLC - Summary of the October 11, 2022, Meeting Between the U.S. Nuclear Regulatory Commission Staff and X Energy, LLC Regarding Xe-100 Reactor Designs Probabilistic Risk Assessment Adequacy Approach White Paper
ML23030A661
Person / Time
Site: 99902071
Issue date: 02/14/2023
From: Stephanie Devlin-Gill
NRC/NRR/DANU/UAL1
To: Jessup W
NRC/NRR/DANU/UAL1
References
EPID L-2022-LRO-0150
Download: ML23030A661 (4)


Text

MEMORANDUM TO:

William T. Jessup, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:

Stephanie Devlin-Gill, Senior Project Manager Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF THE OCTOBER 11, 2022, MEETING BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION STAFF AND X-ENERGY, LLC REGARDING XE-100 REACTOR DESIGNS PROBABILISTIC RISK ASSESSMENT ADEQUACY APPROACH WHITE PAPER Meeting Information:

Applicant: X-Energy, LLC Project No. 99902071 EPID: L-2022-LRO-0150 Meeting

Title:

Public Meeting Regarding Xe-100 Reactor Design's Probabilistic Risk Assessment Adequacy Approach White Paper Meeting Type: Observation Public Meeting Notice: Agencywide Documents Access and Management System (ADAMS)

Accession No: ML22269A384 Applicant Presentation Slides: ML22322A035 Meeting Attendees: See Enclosure for list of meeting attendees.

February 14, 2023 Signed by Devlin-Gill, Stephanie on 02/14/23

W. Jessup Meeting Summary:

The U.S. Nuclear Regulatory Commission (NRC) staff held a virtual observation public meeting with representatives from X-Energy, LLC (X-energy). The meeting was conducted in accordance with NRC Management Directive 3.5, Attendance at NRC Staff-Sponsored Meetings (ML21180A271). The main points of discussion during the meeting included:

X-energy indicated that the Xe-100 Reactor Design's Probabilistic Risk Assessment Adequacy Approach White Paper will only cover the regulations in Title 10 of the Code of Federal Regulations Part 50, Domestic licensing of production and utilization facilities, since this is the proposed licensing pathway for the Xe-100 reactor design.

X-energy stated that the white paper outlines the intended approach for demonstrating probabilistic risk assessment (PRA) technical adequacy consistent with the guidance in Regulatory Guide (RG) 1.247 Acceptability of PRA Results for Non-Light Water Reactors Risk-Informed Activities. X-energy also stated that it plans to follow requirements in the Non-Light Water Reactor (NLWR) PRA standard, ASME/ANS RA-S-1.4-2021, Probabilistic Risk Assessment Standard for Advanced Non-Light Water Reactor Nuclear Power Plants.

X-energy stated that the PRA technical adequacy will be determined by assessing the PRA against the technical requirements of the NLWR PRA standard. X-energy stated that conformance to the PRA standard supporting requirements will increase as the design evolves.

X-energy stated that the Xe-100 PRA will include all radiological sources at the plant and address all internal and external hazards in Appendix B of RG 1.247 for the construction permit application and the operating license application.

Ian Jung (NRC staff) stated that more detailed feedback will be provided to X-energy once the NRC staff following receipt and review of the white paper.

X-energy stated that it plans to have future engagement on preliminary safety analysis report chapters that involve PRA.

X-energy stated that it plans to submit the white paper by October 2022.

CONTACT: Stephanie Devlin-Gill, NRR/DANU 301-415-5301

Enclosure:

List of Meeting Attendees

Pkg: ML23030A605 Letter: ML23030A661 Slides: ML22322A035 NRR-052 OFFICE NRR/DANU/UAL1/PM NRR/DANU/UAL1/LA NRR/DANU/UAL1/BC NRR/DANU/UAL1/PM NAME SDevlin-Gill DGreene WJessup SDevlin-Gill DATE 1/31/2023 2/13/2023 2/14/2023 2/14/2023

Enclosure List of Attendees Public Meeting with X-Energy LLC Regarding Xe-100 Reactor Designs Probabilistic Risk Assessment Adequacy Approach White Paper Error! Reference source not found.

Name Organization Lucieann Vechioli U.S. Nuclear Regulatory Commission (NRC)

Ian Jung NRC Donald Palmrose NRC Hanh Phan NRC Michelle Hart NRC Marie Pohida NRC Anders Gilbertson NRC Shilp Vasavada NRC Timothy Stuhldreher Department of Energy (DOE)

Carl Friesen DOE James Breuninger DOE Ingrid Nordby X-Energy LLC (X-energy)

Harry Liao X-energy Jessa Hultgren X-energy Mark Cursey X-energy Alaina Vivanco X-energy Charlotte Geiger X-energy Raymond Wang X-energy Brando Norris X-energy Mirko Ascic Sargent & Lundy Adam Stein Self Luke McSweeney Self Stephanie Yazzie Self Karl Fleming Self Elliot Korb Self Wesley Steh Self Leigh Lloveras Self Glen Lawson Self Mihai Aurelian Diaconesa Self Edwin Lyman Union of Concerned Scientists