ML23010A197
| ML23010A197 | |
| Person / Time | |
|---|---|
| Site: | 07109337, 07109338, 07100939, 07109398 |
| Issue date: | 01/19/2023 |
| From: | Rivera-Verona A NRC/NMSS/DFM/IOB |
| To: | Ralls S Croft Associates Limited |
| References | |
| IR 2022201 | |
| Download: ML23010A197 (3) | |
See also: IR 07100939/2022201
Text
UNITED STATES
NUCLEAR REGULATORY COMMISSION
WASHINGTON, D.C. 20555-0001
Stephan Ralls
Quality Manager
Croft Associates Limited
Building F4, Culham Science Center
Culham, Abingdon
Oxfordshire, OX14 3DB, England, UK
SUBJECT:
CROFT ASSOCIATES LIMITED - RESPONSE TO THE U.S. NUCLEAR
REGULATORY COMMISSION INSPECTION REPORT NO. 71-0939/2022-201
Dear Stephen Ralls:
This letter refers to Croft Associates Limiteds (Crofts) letter dated November 25, 2022
(Agencywide Documents Access and Management System (ADAMS) Accession No.
ML22340A020), in which you provided a response to the U.S. Nuclear Regulatory
Commission (NRC) Notice of Violation (Notice), dated November 9, 2022
(ML22305A627).
The NRC has reviewed your letter and found it to be responsive to the Notice. No additional
questions or comments have been identified at this time and the NRC may review the
implementation of your corrective actions during a future NRC staff inspection to determine
whether full compliance has been achieved and maintained.
No response to this letter is required.
In accordance with Title 10 of the Code of Federal Regulations Section 2.390 of the NRCs
Rules of Practice, a copy of this letter will be made available electronically for public
inspection in the NRC Public Document Room or from the NRC's ADAMS, accessible from the
NRC website at http://www.nrc.gov/reading-rm/adams.html.
January 19, 2023
S. Ralls
2
Please contact Jon Woodfield of my staff at 301-415-8727 or Jon.Woodfield@nrc.gov, if you
have any questions or need assistance regarding this matter.
Sincerely,
Aida Rivera-Varona, Chief
Inspection and Oversight Branch
Division of Fuel Management
Office of Nuclear Material Safety
and Safeguards
Docket No. 71-0939
Signed by Rivera-Varona, Aida
on 01/19/23
OFFICE
NMSS/DFM
NMSS/DFM
NMSS/DFM
NAME
JWoodfield
WWheatley
ARivera-Varona
DATE
1/17/2023
1/17/2023
1/19/2023