License Amendment Request (License R-110, Docket No. 50-284)
The request
- Remove low power scrams for nuclear safety Channels 2 and 3
- Channel 2 currently has one low power scram to be removed
- Channel 3 has low power scrams in each linear range, but only low scrams in low power ranges (where detector does not function) and in startup range to be removed
Why?
- Old BF3 neutron detectors used in Channels 2 and 3 must be replaced
- BF3 detectors no longer available
- Replacement detectors have less sensitivity at low power levels; therefore no current to control console at low power levels
- Lack of detector current at low power causes Channels 2 and 3 to scram
Safety implications
- None
- No impact on assessment of maximum credible reactivity accident (ISU AGN Safety Analysis Report Section 5.5)
- Estimated power increase has stable period of 1 sec
Overview of scrams with amendment SAFETY CHANNEL SET POINT FUNCTION Nuclear Safety Channel No. 1 (Startup Count Rate Channel)
Low Power Unit A) 5% Full Scale OR Unit B) 0.5 counts/second Scram at levels Below the set points Nuclear Safety Channel No. 2 (Log Power Channel)
High Power 6 watts (120% of licensed power)
Scram at power
> 6 watts Nuclear Safety Channel No. 2 (Log Power Channel)
Low Power 3.0 x 10-13 amperes Scram at source levels
< 3.0 x 10-13 amps Reactor Period 5 sec Scram at periods
< 5 sec Nuclear Safety Channel No. 3 (Linear Power Channel)
High Power 6 watts (120% of licensed power)
Scram at power
> 6 watts Nuclear Safety Channel No. 3 (Linear Power Channel)
Low Power 5% Full Scale (for ranges above startup range)
Scram at levels
< 5% of Full Scale Manual Scram Scram at operator option From Table 3.1 of Facility License R-110 Docket Number 50-284 Amendment 7 Technical Specifications
Comparison with scrams for other AGNs Channel Scram Idaho State University (ISU)
Texas A&M University (A&M)
University New Mexico (UNM)
Channel 1 - Low 5% of full scale or 0.5 counts per second 10 counts per second NA Channel 2 - Low 3.0 x 10-13 amps 1.0 x 10-12 amps NA Channel 2 - High 6 watts 10 watts 6 watts Channel 3 - Low 5% of scale 1.0 x 10-12 amps NA Channel 3 - High 6 watts 10 watts 6 watts