ML22341A005

From kanterella
Jump to navigation Jump to search
Audit Plan for the Regulatory Audit of NuScale Topical Report-107522, Revision 1, Applicability Range Extension of NSP4 Critical Heat Flux Correlation
ML22341A005
Person / Time
Site: 99902078
Issue date: 12/12/2022
From: Bavol B
NRC/NRR/DNRL/NRLB
To: Michael Dudek
NRC/NRR/DNRL/NRLB
References
Download: ML22341A005 (6)


Text

December 12, 2022 MEMORANDUM TO:

Michael I. Dudek, Chief New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation FROM:

Bruce M. Bavol, Project Manager /BMB/

New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation

SUBJECT:

AUDIT PLAN FOR THE REGULATORY AUDIT OF NUSCALE TOPICAL REPORT-107522, REVISION 1, APPLICABILITY RANGE EXTENSION OF NSP4 CRITICAL HEAT FLUX CORRELATION By letter dated November 5, 2021, NuScale Power, LLC submitted Topical Report supplement (TR)-107522, Revision 0, Applicability Range Extension of NSP4 Critical Heat Flux Correlation:

Supplement 1 to TR-0116-21012-P-A, Revision 1, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21309A753 - package). Additional supplemental data tables were sent by letter dated January 14, 2022, (ADAMS Accession No. ML22014A248) - which will be included as Appendix A to the referenced TR. By letter dated October 27, 2022, (ADAMS Accession Nos. ML22300A244 and ML22300A243), NuScale submitted TR-107522, Revision 1, to the U.S. Nuclear Regulatory Commission (NRC) which updated the TR supplement text to include the latest information. The TR supplement seeks to provide the bases for an approval of an extension to the range of applicability for the NSP4 critical heat flux (CHF) correlation. The original NSP4 range of applicability was approved in TR-0116-21012-P-A, Revision 1, NuScale Power Critical Heat Flux Correlations.

On Tuesday, November 15, 2022, NuScale requested via email (ADAMS Accession No. ML22326A016) that the NRC prepare and execute a limited scope audit on new supporting information for the TR supplement. The purpose of the audit is to understand the details and bases for the new information that supports the NSP4 correlation applicability range extension, without penalties on the correlation limit, requested in the TR supplement.

CONTACT:

Bruce Bavol, NRR/DNRL 301-415-6715

The audit will take place at NRC headquarters via use of the NuScale electronic reading room.

The audit entrance will be held on December 12, 2022, as mutually agreed. The audit exit will be held approximately four weeks after the entrance meeting, based on the availability of NuScale and NRC staff. The contents of the audit plan are provided as an enclosure.

Docket No. 99902078

Enclosure:

Audit Plan

ML22341A005

  • via email NRR-106 OFFICE DNRL/NRLB:PM DNRL/NRLB:LA DNRL/NRLB: BC DNRL/NRLB:PM NAME BBavol SGreen*

MDudek* DDrucker for BBavol DATE 12/06/2022 12/08/2022 12/12/2022 12/12/2022 Enclosure UNITED STATES NUCLEAR REGULATORY COMMISSION Audit Plan for The Regulatory Audit of NUSCALE TOPICAL REPORT-107522, REVISION 1, APPLICABILITY RANGE EXTENSION OF NSP4 CRITICAL HEAT FLUX CORRELATION Docket No. 99902078 AUDIT PLAN APPLICANT: NuScale Power, LLC (NuScale)

CONTACTS: Thomas Griffith DURATION:

December 12, 2022 - January 6, 2023 (Approximate Audit Exit)

LOCATION:

U.S. Nuclear Regulatory Commission (NRC) Headquarters (via NuScales electronic reading room (eRR))

One White Flint North 11545 Rockville Pike Rockville, Maryland 20852-2738 NuScale 11333 Woodglen Drive, Suite 205 Rockville, Maryland 20852 NuScale 1100 NE Circle Blvd Corvallis, OR 97330 AUDIT TEAM: Josh Kaizer, (Technical Reviewer) Office of Nuclear Reactor Regulation (NRR)

Bruce Bavol, (Project Manager) (NRR)

Antonio Barrett, (Technical Reviewer) (NRR)

Rosie Sugrue, (Technical Reviewer) (NRR)

2 I.

BACKGROUND AND OBJECTIVES By letter dated November 5, 2021, NuScale Power, LLC submitted Topical Report supplement (TR)-107522, Revision 0, Applicability Range Extension of NSP4 Critical Heat Flux Correlation:

Supplement 1 to TR-0116-21012-P-A, Revision 1, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21309A753 - package). Additional supplemental data tables were sent by letter dated January 14, 2022, (ADAMS Accession No. ML22014A248) - which will be included as Appendix A to the referenced TR. By letter dated October 27, 2022, (ADAMS Accession Nos. ML22300A244 and ML22300A243), NuScale submitted TR-107522, Revision 1, to the NRC, which updated the TR supplement text to include the latest information. The TR supplement seeks to provide the bases for an approval of an extension to the range of applicability for the NSP4 critical heat flux correlation. The original NSP4 range of applicability was approved in TR-0116-21012-P-A, Revision 1, NuScale Power Critical Heat Flux Correlations.

On Tuesday, November 15, 2022, Nuscale requested via email (ADAMS Accession No. ML22326A016) that the U.S. Nuclear Regulatory Commission (NRC) prepare and execute a limited scope audit on new supporting information for the TR supplement. The purpose of the audit is to understand the details and bases for the new information that supports the NSP4 correlation applicability range extension, without penalties to the correlation limit, requested in the TR supplement.

II.

REGULATORY AUDIT BASIS This regulatory audit is based on the following:

This regulatory audit is based on Topical Report supplement TR-107522, Revision 1, Applicability Range Extension of NSP4 Critical Heat Flux Correlation: Supplement 1 to TR-0116-21012-P-A, Revision 1, (ADAMS Accession Nos. ML22300A244 and ML22300A243).

III.

REGULATORY AUDIT SCOPE The audit team will examine supporting documentation and calculations associated with new information provided by NuScale in the eRR that supports the extension of the NSP4 correlation applicability range without penalties to the correlation limit. The audit team will also meet with subject matter expert(s) to discuss details of the information supporting TR-107522, Revision 1.

IV.

INFORMATION AND OTHER MATERIAL NECCSSARY FOR THE REGULATORY AUDIT The NRC staff requests that the following material and information be made available for audit for the new information supporting the TR supplement:

Available plots and supporting calculations that support the NSP4 correlation applicability range extension without penalties to the correlation limit.

V.

SPECIAL REQUESTS The NRC staff requests that NuScale provide subject matter expert(s), if necessary, to discuss the details of the audit material requested in Section IV of this audit plan.

3 VI.

DELIVERABLES The NRC audit team is expected to consist of the above listed individuals who are or have been involved in reviewing Topical Report supplement TR-107522, Revision 1, Applicability Range Extension of NSP4 Critical Heat Flux Correlation: Supplement 1 to TR-0116-21012-P-A, Revision 1. The NRC staff will conduct this audit in accordance with the guidance provided in LIC 111, Regulatory Audits, (ADAMS Accession No. ML19226A274). The NRC staff acknowledges the proprietary nature of the information requested and will handle it appropriately throughout the audit.

The audit will initiate on December 12, 2022, and end after approximately four weeks.

The staff will hold audit calls and/or meetings with NuScale as necessary to understand audit material. The NRC will inform NuScale of emerging information needs as well as documents that can be removed from the eRR.

An audit report will be prepared and issued in accordance with NRR-LIC-111 within 90 days following the completion of the audit. If necessary, any circumstances related to the conduct of the audit will be communicated to, Bruce Bavol, at 301-415-6715 or Bruce.Bavol@nrc.gov.