2. X Energy LLC Email Preliminary Questions Regarding Xe-100 Principal Design Criteria Topical Report
ML22322A176
Person / Time
Site: 99902071
Issue date: 11/17/2022
From: Vechioli L
NRC/NRR/DANU/UAL1
To: Chapman T, Nordby I
X-Energy
Shared Package
ML22322A174 List:
References
Download: ML22322A176 (1)


Text

From:

Lucieann Vechioli Feliciano To:

Travis Chapman; Ingrid Nordby

Subject:

U.S. NRC Preliminary Questions regarding X Energy LLC Topical Report: "Xe-100 Principal Design Criteria Licensing Topical Report" Date:

Thursday, November 17, 2022 1:32:00 PM Attachments:

Preliminary Questions - PDC TR.pdf Mr. Chapman:

By letter dated July 13, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22195A260), X Energy LLC (X-energy) submitted Topical Report XE00-Z-ZZ-ZZ Rev. 1, Xe-100 Principal Design Criteria Licensing Topical Report, for U.S. Nuclear Regulatory Commission (NRC) staff review. Based on its review, the NRC staff developed the attached set of preliminary questions to improve the NRC staffs understanding of the information included in the report.

The NRC staff requests that X-energy propose times to discuss the preliminary questions in a public meeting, which may be closed, as appropriate, to discuss proprietary information.

NRC staff availability to meet is the following:

November 30th 1-3p December 5 2-4p December 6 3-4p

In some instances, preliminary questions may support formal requests for additional information (RAIs). X-energy will be advised of the need for RAIs by separate correspondence.

If you have any questions or need clarifications on the preliminary questions, please do not hesitate to contact me.

Regards,

Lucieann Vechioli Feliciano Pronouns: She, Her, Hers Project Manager U.S. Nuclear Regulatory Commission NRR/DANU/UARL1 Phone: (301) 415-6035 Location: OWF 02-H22 Mail Stop: O-12D20 Email: Lucieann.Vechioli@nrc.gov

P Please consider the environment before printing this e-mail