November 7, 2022 MEMORANDUM TO:
Michael I. Dudek, Chief New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation FROM:
Bruce Bavol, Project Manager /RA/
New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF THE SEPTEMBER 22, 2022, OBSERVATION PUBLIC MEETING TO DISCUSS THE PRE-SUBMITTAL OF THE NUSCALE, POWER LLC, EXTENDED PASSIVE COOLING AND REACTIVITY CONTROL METHODOLOGY TOPICAL REPORT The U.S. Nuclear Regulatory Commission (NRC) held an observation public meeting on September 22, 2022, to discuss the pre-submittal of the NuScale Power, LLC (NuScale),
Extended Passive Cooling and Reactivity Control Methodology Topical Report. NRC and NuScale staff participated in the open portion of the meeting along with several external project stakeholders.
The public meeting notice dated September 22, 2022, can be found in the NRCs Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML22263A140.
Presentation slides from NuScale can be found in under ML22258A280. This meeting notice was also posted on the NRC public website.
Enclosed is the meeting agenda (Enclosure 1), list of attendees (Enclosure 2), meeting overview - public (Enclosure 3), and the meeting overview - non-public (Enclosure 4).
Docket No. 99902052
Enclosures:
- 1. Meeting Agenda
- 2. List of Attendees
- 3. Summary of Open Session
- 4. Summary of Closed, Proprietary Session CONTACT: Bruce M. Bavol, NRR/DNRL 301-415-6715
Package: ML22307A047 Memo: ML22307A123
Enclosure:
- via email NRR-106 OFFICE DNRL/NRLB:PM DNRL/NRLB:LA DNRL/NRLB:PM DNRL/NRLB:BC DNRL/NRLB: PM NAME BBavol*
SGreen*
GTesfaye*
GTesfaye for MDudek*
BBavol*
DATE 11/01/2022 11/03/2022 11/07/2022 11/07/2022 11/07/2022
U.S. NUCLEAR REGULATORY COMMISSION OBSERVATION PUBLIC MEETING TO DISCUSS THE PRE-SUBMITTAL OF THE NUSCALE EXTENDED PASSIVE COOLING AND REACTIVITY CONTROL METHODOLOGY TOPICAL REPORT MEETING AGENDA September 22, 2022 Time Topic 2:30 p.m. - 2:35 p.m.
Welcome and Introductions 2:35 p.m. - 2:55 p.m.
Opening Discussion & NuScale presentation 2:55 p.m. - 3:00 p.m.
Public - Questions and Comments 3:00 p.m. - 4:30 p.m.
Closed Portion 4:30 p.m.
Adjourn
OBSERVATION PUBLIC MEETING TO DISCUSS THE PRE-SUBMITTAL OF THE NUSCALE EXTENDED PASSIVE COOLING AND REACTIVITY CONTROL METHODOLOGY TOPICAL REPORT LIST OF ATTENDEES September 22, 2022 Name Organization Bruce Bavol U.S. Nuclear Regulatory Commission (NRC)
Getachew Tesfaye NRC Andrew Ireland NRC Antonio Barrett NRC Peter Yarsky NRC Michael Dudek NRC John Lehning NRC MJ Ross-Lee NRC Brian Smith NRC Joe Donoghue NRC John Budzynski NRC Omid Tabatabai NRC Zhian Li NRC Shanlai Lu NRC Andrew Bielen NRC Alina Schiller NRC Ricky Vivanco NRC Ben Bristol NuScale Taylor Coddington NuScale Robert Gamble NuScale Thomas Griffith NuScale Kyle Hoover Nuscale Paul Infanger NuScale Chris Kirby NuScale Andy Lingenfelter NuScale Kevin Lynn NuScale Meghan McCloskey NuScale Richard McIntosh NuScale Mark Shaver NuScale Yong Jae Song NuScale Peter Subaiya NuScale Tim Tovar NuScale Yeon Jong Yoo NuScale Sarah Fields Uranium Watch Rani Franovich Breakthrough Institute Leigh Lloveras Breakthrough Institute Paul Gunter Beyond Nuclear Edwin Lyman Union of Concerned Scientists Leigh Ford Snake River Alliance Elliott Korb Radiant Nuclear
U.S. NUCLEAR REGULATORY COMMISSION OBSERVATION PUBLIC MEETING TO DISCUSS THE PRE-SUBMITTAL OF THE NUSCALE EXTENDED PASSIVE COOLING AND REACTIVITY CONTROL METHODOLOGY TOPICAL REPORT The U.S. Nuclear Regulatory Commission (NRC) held an observation public meeting on September 22, 2022, to discuss the pre-submittal of the NuScale Power, LLC (NuScale),
Extended Passive Cooling and Reactivity Control Methodology Topical Report. NRC and NuScale staff participated in the open portion of the meeting along with seven external project stakeholders.
The Extended Passive Cooling and Reactivity Control Methodology Topical Report (TR),
presentation provided an opportunity for NuScale to share overview and context:
Key design changes implemented between the Design Certification (DCA) (NPM-160) design and design for Standard Design Approval application (SDAA) (NPM-20)
Preliminary identification of design change impacts to Chapter 15 safety analysis event progressions, phenomena, evaluation models (EMs), and Extended Passive Cooling (XPC) and Reactivity Control Methodology (RCM) Topical Report NuScales plan to integrate effects of design changes, EM impacts into XPC & RCM Topical Report At the end of the public portion, NRC staff opened up the meeting to questions from the general public with one comment provided. Edwin Lyman (Union of Concerned Scientists) provided a comment where he expressed concern over unresolved safety issues from the DCA review and how he hoped the NRC would perform a detailed standard design approval review.