OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION Mr. Ross Moore Director of Regulatory Affairs Oklo Inc.
3190 Coronado Dr.,
Santa Clara, CA 95054
SUBJECT:
OKLO INC. - U.S. NUCLEAR REGULATORY COMMISSION STAFFS FEEDBACK REGARDING OKLOS STANDARDIZED OPERATONAL PROGRAMS WHITE PAPER
Dear Mr. Moore:
By letter dated August 5, 2022 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22250A515), Oklo Inc. (Oklo), submitted for the U.S. Nuclear Regulatory Commission (NRC) staffs review, a Standardized Operational Programs White Paper, as an enclosure to this letter. This white paper describes the approach to operations that is utilized by Oklo for its advanced fission powerhouses and includes templates for certain operational programs. On August 12, 2022, Oklo provided specific questions that it would like the NRC staff to address in its feedback. The NRC staff was asked to perform a review of this paper and provide written feedback. The enclosure to this letter provides the NRC staffs detailed observations for Oklo to consider.
The Enclosure to this letter contains proprietary information.
When separated from the enclosure this document is DECONTROLLED.
December 2, 2022
OFFICIAL USE ONLY - PROPRIETARY INFORMATION OFFICIAL USE ONLY - PROPRIETARY INFORMATION If you have questions regarding this matter, please contact Donna Williams at (301) 415-1322 or via email at Donna.Williams@nrc.gov.
Sincerely, William Jessup, Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation Project No.: 999902095 enclosure:
As stated cc: tjorf@oklo.com ross@oklo.com Signed by Jessup, William on 12/02/22
Pkg: ML22293B812 Letter: ML22293B811 enclosure 1: ML22293B815 (Proprietary)
NRR-106 OFFICE NRR/DANU/UAL1:PM NRR/DANU/UAL2:LA NRR/DANU/UART:BC NRR/DANU/UAL1:BC NAME DWilliams CSmith MHayes WJessup DATE 10/21/2022 11/19/2022 11/27/2022 12/2/2022