ML22272A594

From kanterella
Jump to navigation Jump to search
Kairos Power, LLC - Submittal of the Preliminary Safety Analysis Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes), Revision 1
ML22272A594
Person / Time
Site: Hermes File:Kairos Power icon.png
Issue date: 09/29/2022
From: Hastings P
Kairos Power
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML22272A593 List:
References
KP-NRC-2209-018
Download: ML22272A594 (4)


Text

KP-NRC-2209-018 Kairos Power LLC www.kairospower.com 707 W Tower Ave, Suite A 5201 Hawking Dr SE, Unit A 2115 Rexford Rd, Suite 325 Alameda, CA 94501 Albuquerque, NM 87106 Charlotte, NC 28211 September 29, 2022 Docket No. 50-7513 US Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Kairos Power LLC Submittal of the Preliminary Safety Analysis Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes), Revision 1

Reference:

Letter, Kairos Power LLC to Document Control Desk, Submittal of the Preliminary Safety Analysis Report for the Kairos Power Fluoride Salt-Cooled, High Temperature Non-Power Reactor (Hermes), September 29, 2021 (ML21272A376)

In September 2021, Kairos Power submitted a Preliminary Safety Analysis Report (PSAR) and two technical reports - KP-TR-017-P, KP-FHR Core Design and Analysis Methodology, and KP-TR-018-P, Postulated Event Analysis Methodology - as part of the Construction Permit Application (CPA) for the Hermes non-power reactor (referenced above).

Kairos Power has submitted various discrete changes to the PSAR, KP-TR-017-P, and KP-TR-018-P to address NRC feedback received as part of the Hermes CPA review. This letter transmits new revisions of these reports to reflect the integration of previously submitted changes.

Revision 1 of the PSAR is provided in Enclosure 1.

The two technical reports contain proprietary information, and Kairos Power requests those portions be withheld from public disclosure in accordance with the provisions of 10 CFR 2.390. Enclosures 2 and 3 provide the proprietary versions of KP-TR-017-P and KP-TR-018-P, respectively. Enclosures 4 and 5 provide the non-proprietary versions of KP-TR-017-NP and KP-TR-018-NP, respectively. An affidavit supporting the withholding request is provided in Enclosure 6.

Additionally, the information indicated as proprietary in these technical reports has also been determined to contain Export Controlled Information. This information must be protected from disclosure pursuant to the requirements of 10 CFR 810.

If you have questions or need additional information, please contact me at hastings@kairospower.com or (704) 336-9596, or Darrell Gardner at gardner@kairospower.com or (704) 769-1226.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on September 29, 2021 Peter Hastings, PE Vice President, Regulatory Affairs and Quality

KP-NRC-2209-018 Page 2

Enclosures:

1) Preliminary Safety Analysis Report (Non-proprietary)
2) KP-FHR Core Design and Analysis Methodology, KP-TR-017-P (Proprietary)
3) Postulated Event Analysis Methodology, KP-TR-018-P (Proprietary)
4) KP-FHR Core Design and Analysis Methodology, KP-TR-017-NP (Non-proprietary)
5) Postulated Event Analysis Methodology, KP-TR-018-NP (Non-proprietary)
6) Affidavit Supporting Request for Withholding from Public Disclosure (10 CFR 2.390) xc (w/enclosure):

William Kennedy, Acting Chief, NRR Advanced Reactor Licensing Branch Benjamin Beasley, Project Manager, NRR Advanced Reactor and Licensing Branch Edward Helvenston, Project Manager, NRR Advanced Reactor and Licensing Branch Samuel Cuadrado de Jesus, NRR Advanced Reactor Licensing Branch Matthew Hiser, NRR Advanced Reactor Licensing Branch

KP-NRC-2209-018 Kairos Power LLC Affidavit and Request for Withholding from Public Disclosure (10 CFR 2.390)

I, Peter Hastings, hereby state:

1.

I am Vice President, Regulatory Affairs and Quality, at Kairos Power LLC (Kairos), and as such I have been authorized by Kairos to review information sought to be withheld from public disclosure in connection with the development, testing, licensing, and deployment of the Kairos reactor and its associated structures, systems, and components, and to apply for its withholding from public disclosure on behalf of Kairos.

2.

The information sought to be withheld, in its entirety, is contained in Kairos Enclosures 4, 5, and 6 to this letter.

3.

I am making this request for withholding, and executing this affidavit in support thereof, pursuant to the provisions of 10 CFR 2.390(b)(1).

4.

I have personal knowledge of the criteria and procedures utilized by Kairos in designating information as a trade secret, privileged, or as confidential commercial or financial information.

Some examples of information Kairos considers proprietary and eligible for withholding under

§2.390(a)(4) include:

a.

Information which discloses process, method, or apparatus, including supporting data and analyses, where prevention of its use by Kairos competitors without license or contract from Kairos constitutes a competitive economic advantage over other companies in the industry; b.

Information, which if used by a competitor, would reduce his expenditure of resources or improve his competitive position in design, manufacture, shipment, installation, assurance of quality; c.

Information which reveals cost or price information, production capacities, budget levels, or commercial strategies of Kairos, its customers, its partners, or its suppliers; d.

Information which reveals aspects of past, present, or future Kairos or customer funded development plans or programs, of potential commercial value to Kairos; e.

Information which discloses patentable subject matter for which it may be desirable to obtain patent protection; and/or f.

Information obtained through Kairos actions which could reveal additional insights into reactor system development, testing, qualification processes, and/or regulatory proceedings, and which are not otherwise readily obtainable by a competitor.

5.

Kairos information contained in Enclosures 2 and 3 to this letter contains details could provide a competitor with a commercial advantage if the information were to be revealed publicly, including:

a.

Technical information for the Kairos Power fluoride salt-cooled high-temperature reactor for core design, in Enclosure 2; and

KP-NRC-2209-018

b.

Technical information for the Kairos Power fluoride salt-cooled high-temperature reactor for postulated event analysis, in Enclosure 3.

6.

Pursuant to the provisions of §2.390(b)(4), the following is furnished for consideration by the Commission in determining whether the information sought to be withheld from public disclosure should be withheld:

a.

The information sought to be withheld from public disclosure is owned and has been held in confidence by Kairos.

b.

The information is of a type customarily held in confidence by Kairos and not customarily disclosed to the public. Kairos has a rational basis for determining the types of information customarily held in confidence by it and, in that connection, utilizes a system to determine when and whether to hold certain types of information in confidence. The application of that system and the substance of that system constitute Kairos policy and provide the rational basis required.

c.

The information is being transmitted to the Commission in confidence and, under the provisions of 10 CFR 2.390, it is to be received in confidence by the Commission.

d.

This information is not readily available in public sources.

e.

Public disclosure of this proprietary information is likely to cause substantial harm to the competitive position of Kairos, because it would enhance the ability of competitors to provide similar products and services by reducing their expenditure of resources using similar project methods, equipment, testing approach, contractors, or licensing approaches. This information is the result of considerable expense to Kairos and has great value in that it will assist Kairos in providing products and services to new, expanding markets not currently served by the company.

f.

The information could reveal or could be used to infer price information, cost information, budget levels, or commercial strategies of Kairos.

g.

Each component of proprietary information pertinent to a particular competitive advantage is potentially as valuable as the total competitive advantage. If competitors acquire components of proprietary information, any one component may be the key to the entire puzzle, thereby depriving Kairos of a competitive advantage.

h.

Unrestricted disclosure would jeopardize the position of Kairos in the world market, and thereby give a market advantage to the competition in those countries.

I declare under penalty of perjury that the foregoing is true and correct.

Executed on: September 29, 2022 Peter Hastings Vice President, Regulatory Affairs and Quality