Text
Russell J. McCallister Federal Cleanup Director Moab Uranium Mill Tailings Remedial Action Project U.S. Department of Energy 200 Grand Avenue, Suite 500 Grand Junction, CO 81501
SUBJECT:
U.S. NUCLEAR REGULATORY COMMISSION STAFFS COMMENTS ON U.S. DEPARTMENT OF ENERGY MOAB URANIUM MILL TAILINGS REMEDIAL ACTION PROJECT ALTERNATIVE FINAL COVER SYSTEM 90 PERCENT DESIGN REPORT (DOCKET WM-00110).
Dear Russell McCallister:
By letter dated April 6, 2022, the U.S. Department of Energy, Office of Environmental Management (DOE-EM), provided the Crescent Junction Disposal Site Evapotranspiration Cover System 90 Percent Design Report to the U.S. Nuclear Regulatory Commission (NRC).
The submittal is available in the NRCs Agencywide Documents Access and Management System (ADAMS) Accession No. ML22096A243. DOE provided the 90 percent design to facilitate the NRC staffs review and understanding of the changes to the remedial action plan that it is considering.
The NRC staff has completed its review of the 90 percent design report and has prepared comments for the DOEs consideration. The NRC staffs comments are focused on aspects of the remedial action plan that are impacted by the proposed change in the cover system design:
geotechnical stability (slope stability and settlement), surface water hydrology and erosion protection, radon attenuation, biointrusion, vegetation, soil properties, and water balance modeling. The NRC staffs comments are provided in the enclosure to this letter and have been organized by the previously stated topics.
The NRC staff is available to clarify its comments, if necessary. The NRC staff recognizes that the U.S. Department of Energy, Office of Legacy Management (DOE-LM) may have additional insights on the ET cover design. Further discussions between DOE-EM, DOE-LM, and the NRC may help identify ways to address the NRC staffs comments. The NRC staff looks forward to working with DOE on this revision to the remedial action plan for the Moab project.
In accordance with Title 10 of the Code of Federal Regulations 2.390, Public inspections, exemptions, requests for withholding, of the NRCs Agency Rules of Practice for Domestic Licensing Proceedings and Issuance of Orders, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records component of NRCs ADAMS. ADAMS is accessible from the NRC website at https://www.nrc.gov/reading-rm/adams.html.
October 3, 2022
R. McCallister If you have any questions regarding this letter, please contact me at (301) 415-0724, or by e-mail at Douglas.Mandeville@nrc.gov.
Sincerely, Douglas T. Mandeville, Project Manager Uranium Recovery and Materials Decommissioning Branch Division of Decommissioning, Uranium Recovery and Waste Programs Office of Nuclear Material Safety and Safeguards Docket No.: WM-00110
Enclosure:
NRC Staff Comments on DOE 90 Percent Design cc: C. Pulskamp (DOE)
Moab Mill ListServ Signed by Mandeville, Douglas on 10/03/22
ML22262A065; Ltr ML22262A067 OFFICE NMSS/DUWP
/URMDB RES/DRA/FXHAB NMSS/DUWP
/URMDB NMSS/DUWP
/URMDB NAME DMandeville STabatabai RVon DMandeville DATE Sep 26, 2022 Sep 27, 2022 Oct 1, 2022 Oct 3, 2022