Global Nuclear Fuel RAJ-II Safety Analysis Report Amendment Pre-submittal Meeting September 7, 2022 r

Global Nuclear IFuel

Agenda

  • Purpose - Expand Existing RAJ-II Safety Basis (public)
  • Description of the requested additional payload and SAR amendment (public)
  • Overview of SAR Changes (non-public)
  • Overview of Proposed CoC Changes (non-public)
  • Timeline (non-public) r Global Nuclear IFuel 2

Purpose Introduce and provide NRC with technical information regarding an amendment for Revision 11 of the Safety Analysis Report (SAR) to expand payload content parameters of the RAJ-II container, Certificate of Compliance (CoC) 9309.

r Global Nuclear IFuel 3

Summary of RAJ-II SAR Amendment No package or hardware modifications.

Increase allowed Uranium-235 (U-235) enrichment up to 8 wt. 0/o for GNF 1 Ox1 0 fuel bundle and loose light water rod contents.

Increase Criticality Safety Index (CSI) for increased U-235 enrichment content (>5 wt. 0/o ).

New content will be introduced as an amendment to the RAJ-II SAR.

Minor administrative SAR updates will also be provided.

A proposed RAJ-II CoC mark-up will be provided as part of the amendment submittal.

r Global Nuclear IFuel 4

l.{)

z 0

en en

~

0 en c

0

...J aJ

~

D..

LL 0

IL

loo

~

e c

0.. ~

z

~

.CI c -

w

LEU+ Contents Low Enriched Uranium Plus (LEU+)

Increase in allowed maximum U-235 content

  • Current RAJ-II CoC 9309 Rev.12 allows:
  • 5.00 X 1 o-2 g/gU
  • 8.00 X 1 o-2 g/gU r

Global Nuclear IFuel 6

Changes by Chapter Chapters 1, 2, 3, 7, 8

  • Updates to incorporate new LEU+ contents Chapter 4
  • Updated leak rate calculation and evaluation based on LEU+ contents Chapter 5
  • Updated shielding calculation and evaluation based on LEU+ contents r

Global Nuclear IFuel 7

Chapter 6 General Changes

  • CSI = 1.6 for an 8x8 package array with 5-8 wt. 0/o U-235 range Minimalistic Approach
  • Supporting calculations are performed to ensure criticality safety
  • If the current conclusions in the subsections of Chapter 6 hold, no update to the section is made r

Global Nuclear IFuel 8

Chapter 6 Fuel Assembly Loading Criteria (SAR Table 6-1)

  • Increase in minimum number of gad rods in the 5 - 8 wt. 0/o U-235 range
  • Determination of lattice enrichment for a CSI 1.6 with no gadolinia Loose Rods
  • Confirming the number of LEU+ rods for safe shipment r

Global Nuclear IFuel 9

Chapter 6 Validation

  • No update is made to the SCALE 6.1 & KENO-VI validation as it already covers the 5 - 8 wt. 0/o U-235 range SCALE User Notices 10
  • Notice regarding h-poly: Clarification is made that all polyethylene is modelled as poly(h2o)
  • Notice regarding SCALE 6.2.2 - 6.2.4 with KENO-V:

Not applicable as SCALE 6.1 & KENO-VI are used r

Global Nuclear IFuel

Proposed CoC Changes

  • Update to the revisions of some RAJ-II drawings
  • Authorized contents for 8 wt0/o fuel
  • Allowance of up to 8 wt0/o for GNF 1 Ox1 0 fuel
  • Gadolinia requirements for the 5 - 8 wt. 0/o U-235 range
  • Addition to maximum quantity of material per package
  • Clarification of CSI and applicable contents
  • Administrative updates r

Global Nuclear IFuel 11

Submittal Schedule

  • GNF-A plans to submit RAJ-II SAR, Revision 11, amendment request in the 3rd quarter 2022.
  • NRC approval is requested within one year after submittal.

r Global Nuclear IFuel 12