KP-NRC-2208- 007

Enclosure 1 Response to PSAR 9.1 RCI (Non-Proprietary)

KairosPowerHermesTestReactor PreliminarySafetyAnalysisReport ResponsestoRequestsforConfirmatoryInformation

ChemistryControlSystem

RCI01

KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthesystemtomaintainthepurityofthereactor coolantwithinspecifieddesignlimits.

InordertodemonstratehowthedesignbasesforthechemistrycontrolsystemsatisfyPDC70,confirm thefollowinginformationforSection9.1.1:

WillinformationintheFSARshowtheselectedlocation(s)forcoolantchemistrysamplingtobeawell mixed,representativesampleofthecoolant?

KairosPowerResponse:

Yes,informationprovidedwiththeapplicationforanoperatinglicensewillshowtheselectedlocation(s) forcoolantchemistrysamplingtobewellmixed,representativesamplesofthecoolant.

InertGasSystem

RCI02

KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.

Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:

WilltheIGSbecapableofmeasuringbothairandmoisturecontentofthecovergas?

KairosPowerResponse:

Yes,theIGSwillbecapableofmeasuringboththeairandmoisturecontentofthecovergas.

1of2 RCI03

KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.

Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:

CantheentiretyoftheIGSbeperiodicallycheckedforleakage?

KairosPowerResponse:

Yes,theentiretyoftheIGScanbeperiodicallycheckedforleakage.

RCI04

InordertoclarifythedesignbasesoftheIGS,confirmthefollowinginformationforSection9.1.2:

IstheIGSneededtocontrolthe'hotcell'temperaturestatedinChapter13,TableA51,"KeyInput ParametersforPebbleHandlingandStorageSystemMalfunctionEvent?"

KairosPowerResponse:

No,theIGSisnotneededtocontrolthehotcelltemperaturereferencedintheanalysisofthePHSS MalfunctionEvent.