Text
KP-NRC-2208- 007
Enclosure 1 Response to PSAR 9.1 RCI (Non-Proprietary)
KairosPowerHermesTestReactor PreliminarySafetyAnalysisReport ResponsestoRequestsforConfirmatoryInformation
ChemistryControlSystem
RCI01
KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthesystemtomaintainthepurityofthereactor coolantwithinspecifieddesignlimits.
InordertodemonstratehowthedesignbasesforthechemistrycontrolsystemsatisfyPDC70,confirm thefollowinginformationforSection9.1.1:
WillinformationintheFSARshowtheselectedlocation(s)forcoolantchemistrysamplingtobeawell mixed,representativesampleofthecoolant?
KairosPowerResponse:
Yes,informationprovidedwiththeapplicationforanoperatinglicensewillshowtheselectedlocation(s) forcoolantchemistrysamplingtobewellmixed,representativesamplesofthecoolant.
InertGasSystem
RCI02
KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.
Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:
WilltheIGSbecapableofmeasuringbothairandmoisturecontentofthecovergas?
KairosPowerResponse:
Yes,theIGSwillbecapableofmeasuringboththeairandmoisturecontentofthecovergas.
1of2 RCI03
KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.
Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:
CantheentiretyoftheIGSbeperiodicallycheckedforleakage?
KairosPowerResponse:
Yes,theentiretyoftheIGScanbeperiodicallycheckedforleakage.
RCI04
InordertoclarifythedesignbasesoftheIGS,confirmthefollowinginformationforSection9.1.2:
IstheIGSneededtocontrolthe'hotcell'temperaturestatedinChapter13,TableA51,"KeyInput ParametersforPebbleHandlingandStorageSystemMalfunctionEvent?"
KairosPowerResponse:
No,theIGSisnotneededtocontrolthehotcelltemperaturereferencedintheanalysisofthePHSS MalfunctionEvent.
2of2