KP-NRC-2208-007 Response to PSAR 9.1 RCI (Non-Proprietary)

1of2 KairosPowerHermesTestReactor PreliminarySafetyAnalysisReport ResponsestoRequestsforConfirmatoryInformation

ChemistryControlSystem RCI01 KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthesystemtomaintainthepurityofthereactor coolantwithinspecifieddesignlimits.

InordertodemonstratehowthedesignbasesforthechemistrycontrolsystemsatisfyPDC70,confirm thefollowinginformationforSection9.1.1:

WillinformationintheFSARshowtheselectedlocation(s)forcoolantchemistrysamplingtobeawell mixed,representativesampleofthecoolant?

KairosPowerResponse:

Yes,informationprovidedwiththeapplicationforanoperatinglicensewillshowtheselectedlocation(s) forcoolantchemistrysamplingtobewellmixed,representativesamplesofthecoolant.

InertGasSystem RCI02 KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.

Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:

WilltheIGSbecapableofmeasuringbothairandmoisturecontentofthecovergas?

KairosPowerResponse:

Yes,theIGSwillbecapableofmeasuringboththeairandmoisturecontentofthecovergas.

2of2

RCI03 KPFHRPDC70,"Reactorcoolantpuritycontrol,"requiresthatcoolantpuritylimitsbebasedon considerationofairormoistureingressduetoacovergasleak.

Inordertodemonstratehowthedesignbasesfortheinertgassystem(IGS)satisfyPDC70,confirmthe followinginformationforSection9.1.2:

CantheentiretyoftheIGSbeperiodicallycheckedforleakage?

KairosPowerResponse:

Yes,theentiretyoftheIGScanbeperiodicallycheckedforleakage.

RCI04 InordertoclarifythedesignbasesoftheIGS,confirmthefollowinginformationforSection9.1.2:

IstheIGSneededtocontrolthe'hotcell'temperaturestatedinChapter13,TableA51,"KeyInput ParametersforPebbleHandlingandStorageSystemMalfunctionEvent?"

KairosPowerResponse:

No,theIGSisnotneededtocontrolthehotcelltemperaturereferencedintheanalysisofthePHSS MalfunctionEvent.