KP-NRC-2208-008 Change to Hermes PSAR Chapter 14 (Non-Proprietary)
PreliminarySafetyAnalysisReport
TechnicalSpecifications
KairosPowerHermesReactor 145 Revision0 Section SectionName LCOorCondition Basis Inletgassystempressureis maintainedwithinanupper boundlimit.
Theobjectiveistolimitthe quantityandpressureof spilledFlibeorcovergasto ensureapostulatedevent doesnotexceedlimits.
Argonpurityinthecovergasis maintainedwithinanupper boundlimit.
Theobjectiveistolimit radionuclidesintheFlibe belowsolubilitylimitswhere solutesoluteinteractionscan beneglected.
Thequantityofmaterialsatrisk inthegasspaceoftheprimary heattransportsystemandthe primaryheatrejectionsystemis maintainedwithinanupper boundlimit.
Theobjectiveistolimitthe quantityofmaterialsatrisk inthecovergastoensurea postulatedeventdoesnot exceedlimits.
3.4 EngineeredSafety Features Decayheatremovalsystem operability Theobjectiveistospecifythe requirementtohavean operabledecayheatremoval systemtoensurethatthe safetylimitswillnotbe exceeded.
Reactorvesselintegrity Theobjectiveistospecifya designoperating temperaturelimittoensure thesafetylimitisnot exceededforpostulated events.
3.5 VentilationSystems N/A N/A 3.6 EmergencyPower N/A N/A 3.7 RadiationMonitoring SystemsandEffluents Radiationmonitoringsystemis designedtobeavailableduring normaloperatingconditionsas wellasduringpostulatedevents.
Radiationinplanteffluentsis measuredagainstapplicable limits.
3.8 Experiments N/A N/A 3.9 FacilitySpecificLCOs N/A N/A