KP-NRC-2208-006 Changes to PSAR Table 4.2-5 (Non-Proprietary)

Preliminary Safety Analysis Report Reactor Description Kairos Power Hermes Reactor Revision 0 4-18 Table 4.2-5: Fuel Qualification Envelope Parameter Existing TRISO Particle Qualification Envelope Peak Fuel SiC Temperature - Normal Operation (°C) 1360 Peak Fuel SiC Temperature - Transient (°C) 1600 Burnup (%FIMA) 19.613.2 Peak Particle Power (mW) 155 Peak Fluence (x1025n/m2, E>0.1MeV) 4.73.8