ML22228A266

From kanterella
Jump to navigation Jump to search
GEH BWRX-300 SMR - -A LTR Verification GEH BWRX-300 NEDC-33922, Containment Evaluation Method
ML22228A266
Person / Time
Site: 99900003
Issue date: 08/16/2022
From:
NRC
To:
NRC/NRR/DNRL/NRLB
References
Download: ML22228A266 (6)


Text

From:

Shea, Jim Sent:

Tuesday, August 16, 2022 8:20 PM To:

Diaz-Quiroz, Jesus G. (GE Power Portfolio); Schichlein, Lisa (GE Power Portfolio); GEH-BWRX-300DocsPEm Resource Cc:

Catts, Michelle (GE Power); Wadkins, George (GE Power); Dudek, Michael; Glisan, Jordan; Patton, Rebecca; Lu, Shanlai; Krepel, Scott; Haider, Syed

Subject:

-A LTR Verification GEH BWRX-300 NEDC-33922, Containment Evaluation Method Attachments:

-A Version Verification Letter ML22196A010.pdf; LTR Verification Form NRC 896 GEH BWRX-300 LTR NEDC-33922 ML22196A009.pdf Jesús/Lisa, In a letter dated August 15, 2022 (NRC Verification Letter ADAMS Accession No. ML22196A010, attached), the NRC staff verified that the submitted -A version is acceptable and is approved for referencing in future licensing applications for the BWRX-300 to the extent specified and under the limitations delineated. In addition, the signed NRC LTR Verification Form 896 is attached.

The -A version will be linked on the NRC BWRX-300 public website.

https://www.nrc.gov/reactors/new-reactors/smr/bwrx-300.html James Shea Senior Project Manager phone: (301)415-1388 james.shea@nrc.gov U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Mail Stop O-7D21 Washington, DC, 20555-0001

Hearing Identifier:

GEH_BWRX300_Docs_Public Email Number:

18 Mail Envelope Properties (BLAPR09MB689980AAECB9D0AB0019BFF1946A9)

Subject:

-A LTR Verification GEH BWRX-300 NEDC-33922, Containment Evaluation Method Sent Date:

8/16/2022 8:20:04 PM Received Date:

8/16/2022 8:20:09 PM From:

Shea, Jim Created By:

James.Shea@nrc.gov Recipients:

"Catts, Michelle (GE Power)" <Michelle.Catts@ge.com>

Tracking Status: None "Wadkins, George (GE Power)" <George.Wadkins@ge.com>

Tracking Status: None "Dudek, Michael" <Michael.Dudek@nrc.gov>

Tracking Status: None "Glisan, Jordan" <Jordan.Glisan@nrc.gov>

Tracking Status: None "Patton, Rebecca" <Rebecca.Karas@nrc.gov>

Tracking Status: None "Lu, Shanlai" <Shanlai.Lu@nrc.gov>

Tracking Status: None "Krepel, Scott" <Scott.Krepel@nrc.gov>

Tracking Status: None "Haider, Syed" <Syed.Haider@nrc.gov>

Tracking Status: None "Diaz-Quiroz, Jesus G. (GE Power Portfolio)" <Jesus.Diaz-Quiroz@ge.com>

Tracking Status: None "Schichlein, Lisa (GE Power Portfolio)" <lisa.schichlein@ge.com>

Tracking Status: None "GEH-BWRX-300DocsPEm Resource" <GEH-BWRX-300DocsPEm.Resource@usnrc.onmicrosoft.com>

Tracking Status: None Post Office:

BLAPR09MB6899.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 799 8/16/2022 8:20:09 PM

-A Version Verification Letter ML22196A010.pdf 257433 LTR Verification Form NRC 896 GEH BWRX-300 LTR NEDC-33922 ML22196A009.pdf 1349535 Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

August 15, 2022 Ms. Michelle Catts Senior Vice President, Nuclear Programs GE-Hitachi Nuclear Energy Americas, LLC P.O. Box 780, M/C A-18 Wilmington, NC 28402

SUBJECT:

U.S. NUCLEAR REGULATORY COMMISSION VERIFICATION LETTER AND PROPRIETARY DETERMINATION FOR GE-HITACHI LICENSING TOPICAL REPORT NEDC-33922P-A, Revision 3, BWRX-300 CONTAINMENT EVALUATION METHOD

Dear Ms. Catts:

By letter dated June 17, 2022, GE-Hitachi Nuclear Energy Americas, LLC (GEH), submitted the approved version of Licensing Topical Report (LTR) NEDC-33922P-A, Revision 3, BWRX-300 Containment Evaluation Method (-A) (Agencywide Documents Access and Management System (ADAMS) Accession No. ML22168A012), to the U.S. Nuclear Regulatory Commission (NRC) staff for final verification in support of a future licensing application for the GEH small modular reactor under Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Domestic Licensing of Production and Utilization Facilities, or Part 52, Licenses, Certifications, and Approvals for Nuclear Power Plants.

GEH submitted the -A version of the subject LTR in accordance with the NRC request to publish an approved version, as detailed in the staff final safety evaluation transmittal letter dated April 27, 2022 (ML22110A008).

In Enclosure 3, of the June 17, 2022, submittal, GEH included an affidavit (ML22168A015) with a request that the proprietary information contained in NEDC-33922P-A, Revision 3 (ML22168A013 proprietary version and NEDO-33922-A, Revision 3, ML22168A014 public version), be withheld from public disclosure pursuant to 10 CFR Part 2, Section 2.390. The staff evaluated the request for withholding information marked as proprietary pursuant to10 CFR Section 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended and found it appropriate as marked in all the GEH submittals associated with this LTR.

Therefore, the -A version of the submitted LTR marked as proprietary, will be withheld from public disclosure under 10 CFR 2.390(b)(5) and Section 103(b) of the Atomic Energy Act of 1954, as amended.

The NRC staff has verified that the submitted -A version is acceptable and is approved for referencing in future licensing applications for the BWRX-300 to the extent specified and under the limitations delineated.

If the NRCs criteria or regulations change so that its conclusion in this letter (that the LTR is acceptable) is invalidated, GEH and/or an applicant referencing the LTR will be expected to revise and resubmit its respective documentation or submit justification for the continued applicability of the LTR without revision of the respective documentation.

If you have any questions or comments concerning this matter, I can be reached via e-mail at James.Shea@nrc.gov.

Sincerely,

/RA/

James J. Shea, Senior Project Manager New Reactor Licensing Branch Division of New and Renewed Licenses Office of Nuclear Reactor Regulation Docket No.: 99900003 cc: GEH BWRX-300 NEDC-33922P ListServ

PKG: ML22196A007 LTR: ML22196A010

  • via email NRR-106 OFFICE DNRL/NRLB:PM DNRL/NRLB:LA DNRL/NRLB: BC NAME JShea*

SGreen*

MDudeck*

DATE 07/14/2022 07/18/2022 08/15/2022

NRC FORM 896 (01-2021)

-A Topical Report Verification U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 896 (01-2021)

Page 1 of 1 Topical Report Information Report Number:

NEDC-33922P-A, Revision 3,

Title:

BWRX-300 Containment Evaluation Method ADAMS Accession Number:

ML22168A011 Package EPID:

L-2020-TOP-0055 Docket Number:

99900003 Review Information Office/Division/

Branch:

NRR/DSS/SNSB(Lead Branch); NRR/DSS/

SNRB; NRR/DSS/SCPB Project Manager:

James Shea Reviewers:

Syed Haider, Shanlai Lu Lead, et al Staff Verification Determination ADAMS Accession Numbers for this Review Package: ML22196A007 E-mail: ML22196A008 This Form: ML22196A009

The NRC staff has determined that the topical report is acceptable to the extent delineated in the NRC staff's safety evaluation dated:

03/09/2022 ADAMS Accession No.: ML22004A079 Based on its review of the changes documented in the topical report, the NRC staff has determined that the -

A report is not acceptable for referencing in licensing actions.

Basis for Denial:

Approvals Technical Branch Chief Projects Branch Chief Diana Woodyatt Digitally signed by Diana Woodyatt Date: 2022.08.03 09:48:04 -04'00' Michael I. Dudek Digitally signed by Michael I. Dudek Date: 2022.08.03 10:35:38 -04'00'