ND-22-0655, ITAAC Closure Notification on Completion of ITAAC 2.5.01.03a (Index Number 511)

From kanterella
(Redirected from ML22224A084)
Jump to navigation Jump to search
ITAAC Closure Notification on Completion of ITAAC 2.5.01.03a (Index Number 511)
ML22224A084
Person / Time
Site: Vogtle Southern Nuclear icon.png
Issue date: 08/12/2022
From: Coleman J
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
ND-22-0655
Download: ML22224A084 (7)


Text

A Southern Nuclear August 12,2022 Docket No.:

52-026 U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Jamie M. Coleman Regulatory Affairs Director Vogtle 3 & 4 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 4 7825 River Road Waynesboro, GA 30830 706-848-6926 tel ND-22-0655 10 CFR 52.99(c)(1)

ITAAC Closure Notification on Completion of ITAAC 2.5.01.03a [Index Number 511]

Ladies and Gentlemen:

In accordance with 10 CFR 52.99(c)(1 ), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) of the completion of Vogtle Electric Generating Plant (VEGP) Unit 4 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.5.01.03a [Index Number 511]. This ITAAC confirms that the signal processing hardware of the Diverse Actuation System uses input modules, output modules, and microprocessor or special purpose logic processor boards that are different than those used in the Protection and Safety Monitoring System. The closure process for this ITAAC is based on the guidance described in Nuclear Energy Institute (NEI) 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.

This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staff confirmation of this determination and publication of the required notice in the Federal Register per 10 CFR 52.99.

If there are any questions, please contact Kelli Roberts at 706-848-6991.

Respectfully submitted,

~CJ£t~V\\

Jamie M. Coleman Regulatory Affairs Director Vogtle 3 & 4

Enclosure:

JMC/T JC/sfr Vogtle Electric Generating Plant (VEGP) Unit 4 Completion of ITAAC 2.5.01.03a [Index Number 511]

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 2 of 3 To:

Southern Nuclear Operating Company/ Georgia Power Company Mr. Peter P. Sena Ill (w/o enclosures)

Mr. D. L. McKinney (w/o enclosures)

Mr. M. D. Meier (w/o enclosures)

Mr. G. Chick Mr. S. Stimac Mr. P. Martino Mr. M. J. Yox Mr. A. S. Parton Ms. K. A. Roberts Mr. C. T. Defnall Mr. C. E. Morrow Mr. J.M. Fisher Mr. R. L. Beilke Mr. S. Leighty Ms. A. C. Chamberlain Mr. J. C. Haswell Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:

Nuclear Regulatory Commission Ms. M. Bailey (w/o enclosures)

Mr. M. King Ms. A. Veil Mr. C. P. Patel Mr. G. J. Khouri Mr. C. J. Even Mr. B. J. Kemker Ms. N. C. Coovert Mr. C. Welch Mr. J. Gaslevic Mr. 0. Lopez-Santiago Mr. G. Armstrong Mr. M. Webb Mr. T. Fredette Mr. C. Santos Mr. B. Davis Mr. J. Vasquez Mr. J. Eargle Mr. E. Davidson Mr. T. Fanelli Mr. S. Rose Ms. K. Mccurry Mr. J. Parent Mr. B. Griman

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 3 of 3 Oglethorpe Power Corporation Mr. R. B. Brinkman Mr. E. Rasmussen Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. S. M. Jackson Dalton Utilities Mr. T. Bundros Westinghouse Electric Company, LLC Dr. L. Oriani (w/o enclosures)

Mr. D. C. Durham (w/o enclosures)

Mr. M. M. Corletti Mr. Z. S. Harper Mr. J. L. Coward Other Mr. S. W. Kline, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.

Dr. W. R. Jacobs, Jr., Ph.D., GOS Associates, Inc.

Mr. S. Roetger, Georgia Public Service Commission Mr. R. L. Trokey, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. S. Blanton, Balch Bingham

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 1 of 4 Southern Nuclear Operating Company ND-20-0756 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.5.01.03a [Index Number 511]

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 2 of 4 IT AAC Statement Design Commitment 3.a) The signal processing hardware of the DAS uses input modules, output modules, and microprocessor or special purpose logic processor boards that are different than those used in the PMS.

Inspections, Tests, Analyses Inspection of the as-built DAS and PMS signal processing hardware will be performed.

Acceptance Criteria The DAS signal processing equipment uses input modules, output modules, and micro-processor or special purpose logic processor boards that are different than those used in the PMS. The difference may be a different design, use of different component types, or different manufacturers.

ITAAC Determination Basis Inspections were performed to confirm that the as-built signal processing hardware of the Diverse Actuation System (DAS) uses input modules, output modules, and microprocessor or special purpose logic processor boards that are different from those used in the Protection and Safety Monitoring System (PMS). The results of the inspections verified that the DAS utilizes both a different design and different component types of signal processing hardware than that used in the PMS.

Inspection of the DAS and PMS design specifications and topical reports verified that DAS and PMS utilize both a different design and different component types of signal processing hardware. The design of the DAS, documented in the DAS Design Specification (Reference 1 ),

utilizes an Advanced Logic System (ALS) hardware configuration with input, output, core logic, and communications boards. The ALS is a logic-based platform that does not utilize a microprocessor or software for operation, but instead relies on simple hardware architecture.

The logic is implemented using field-programmable gate array technology. The ALS design is further described in the ALS Topical Report (Reference 2). This is different from the design of the PMS, documented in the PMS Design Specification (Reference 3), which utilizes the Common Qualified (Q) platform with the AC160 controller with multiprocessing capability for signal processing. The Common Q platform is a computer system consisting of a set of commercial-grade hardware and software components dedicated and qualified for use in nuclear power plants. This design is further described in the Common Q Platform Topical Report (Reference 4).

Inspections of the as-built DAS and PMS cabinets (References 5 and 6) were performed at Westinghouse prior to shipment to the plant site in accordance with NEI 08-01 Section 9.5 (Reference 7) because it is impractical to inspect the signal processing hardware within the cabinets after the cabinets are installed on site. The inspections used the system cabinet configuration drawings (References 8 and 9) and confirmed that the as-built configuration of the DAS equipment uses different component types of signal processing hardware than that of the PMS. The as-built drawings for the cabinet configuration for the DAS and PMS document that the as-built cabinets conform to the design, thereby utilizing different design and component types of signal processing hardware.

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 3 of 4 Upon arrival at the plant site, receipt inspections of the DAS and PMS cabinets were performed and documented in Material Receiving Reports (References 1 o and 11) and confirmed each cabinet was received and arrived in an acceptable condition with no open items or corrective actions required. The cabinets were subsequently installed in their final as-built location and installation inspections (Reference 12) confirmed the cabinets contained no evidence to indicate that the signal processing hardware was adversely impacted during installation.

Together, References 1 through 12 confirm that the DAS signal processing equipment used input modules, output modules, and micro-processor or special purpose logic processor boards that are different than those used in the PMS.

References 1 through 12 are available for NRG inspection as part of the Unit 3 ITAAC 2.5.01.03a Completion Package (Reference 13).

ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a review of all IT AAC findings pertaining to the subject ITAAC and associated corrective actions. This review found there are no relevant IT AAC findings associated with the ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 2.5.01.03a (Reference 13) and is available for NRC review.

IT AAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.5.01.03a was performed for VEGP Unit 3 and that the prescribed acceptance criteria are met.

Systems, structures, and components verified as part of this IT AAC are being maintained in their as-designed, ITAAC compliant condition in accordance with approved plant programs and procedures.

References (available for NRC inspection)

1. SV3-DAS-J4-001, "AP1000 Diverse Actuation System System Design Specification",

Revision 3

2. 6002-00301-NP, "Advanced Logic System Topical Report", Revision 4
3. SV3-PMS-J4-020, "AP1000 System Design Specification for the Protection and Safety Monitoring System", Revision 11
4. WCAP-16097-NP-A, "Common Qualified Platform Topical Report, Revision 3
5. SV3-DAS-VQQ-001, "Quality Release & Certificate of Conformance", Revision 1
6. SV3-PMS-VQQ-001, "Quality Release & Certificate of Conformance", Revision 0
7. NEI 08-01, "Industry Guideline for the ITAAC Closure Process Under 10 CFR Part 52",

Revision 5 - Corrected

8. SV3-DAS-J8Y-001, "Vogtle Unit 3 AP1000 Diverse Actuation System Cabinet Configuration Drawing Package", Revision 3
9. SV3-PMS-J8Y-001, "Vogtle Unit 3 AP1000 Protection and Safety Monitoring System Cabinet Configuration Drawing Package", Revision 6
10. J132175-MRR-15-01219, "Unit 3 DAS Material Receiving Report", Revision 0
11. J132175-MRR-16-02318, "Unit 3 PMS Material Receiving Report", Revision 0

U.S. Nuclear Regulatory Commission ND-20-0756 Enclosure Page 4 of 4

12. SV3-DAS-ITR-800511, "Unit 3 Inspection Results of Diverse Actuation System (DAS) Signal Processing Diversity: ITAAC 2.5.01.03a NRG Index Number: 511", Revision 0
13. 2.5.01.03a-U3-CP-Rev 0, ITAAC Completion Package"