MEMORANDUM TO:

Shana R. Helton, Director Division of Fuel Management Office of Nuclear Material Safety and Safeguards FROM:

John R. Tappert, Director Division of Risk Analysis Office of Nuclear Regulatory Research

SUBJECT:

RESEARCH INFORMATION LETTER 2022-08, HUMAN RELIABILITY ANALYSIS OF SEE-AND-FLEE ACTIONS USING THE INTEGRATED HUMAN EVENT ANALYSIS SYSTEM FOR EVENTS AND CONDITION ASSESSMENT METHOD The Office of Nuclear Regulatory Research (RES) is providing for your information and use Research Information Letter 2022-08, Human Reliability Analysis of See-and-Flee Actions Using the Integrated Human Event Analysis System for Event and Condition Assessment (IDHEAS-ECA) Method. This report presents a human reliability analysis (HRA) of hypothetical see-and-flee events at a fuel cycle facility using the IDHEAS-ECA method and will be published as a Research Information Letter (RIL). The IDHEAS-ECA method was published as NUREG-2256 and is currently available in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML22300A117.

This report demonstrates the use of the IDHEAS-ECA HRA method to estimate the reliability of administrative Items Relied on for Safety (IROFS). Specifically, this study estimated the reliability of see-and-flee IROFS in three different scenarios (contexts) to demonstrate the IDHEAS-ECAs ability to assess the reliability of the same IROFS performed in different conditions. This ability would supplement the guidance of NUREG-1520 Standard Review Plan for Fuel Cycle Facilities License Applications (ADAMS Accession No. ML15176A258) in specifying the probability index numbers with sound technical basis. IDHEAS-ECA can be added to the Office of Nuclear Material Safety and Safeguards (NMSS) tool set to assess administrative IROFS reliability and supplement the guidance in NUREG-1520. This report also demonstrates that IDHEAS-ECA can identify dominant reliability drivers. The information in this report will be useful for licensees to effectively use limited resources to improve reliability, and for the NRC staff to evaluate the impacts of the reliability.

CONTACT: John Grasso, RES/DRA/HFRB 301-415-3502 January 6, 2023 Araguas, Christian signing on behalf of Tappert, John on 01/06/23

S. Helton RES proposes developing training materials on using IDHEAS-ECA, with a focus on NMSS applications, and providing training to the interested NMSS staff and licensees. If you support the RES proposal, please having your staff contact Mr. John Grasso to establish a User Need Request for RES to develop and deliver the training materials and training.

RES worked closely with NMSS to ensure that the cognizant staff members from each organization were satisfied with the quality and completeness of the work products prior to transmittal of the final reports. We expect that this close working relationship will continue.

RES has established an online quality survey to collect feedback from user offices on the usefulness of RES products and services. This survey can be found online at this hyperlink.

RES would appreciate the responsible manager or supervisor completing this shortabout 5 minutessurvey within the next 10 working days to present your offices views of the delivered RES product.

Enclosure:

RIL 2022-08; Human Reliability Analysis of See-and-Flee Actions Using the Integrated Human Event Analysis System for Events and Condition Assessment Method

ML22216A166; Memo ML22216A188 OFFICE OCHCO/ADHRTD

/NRANB NMSS/DFM/CTCFB NMSS/REFS NAME JGrasso JPiotter JTappert CAraguas for DATE Aug 8, 2022 Dec 19, 2022 Jan 6, 2023