UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION REPORT Docket No. 71-9373 Model No. HI-STAR 190 Package Certificate of Compliance No. 9373 Revision No. 2
SUMMARY
By letter dated June 1, 2022, (Agencywide Documents Access and Management System ADAMS Accession No: ML22152A257), Holtec International requested renewal of the Certificate of Compliance (CoC) No. 9373 for the Model No. HI-STAR 190 package. The Certificate of Compliance No. 9373, Revision No. 2, was renewed for five years.
EVALUATION By letter dated June 1, 2022, Holtec International requested renewal of CoC No. 9373 for the Model No. HI-STAR 190 package. No changes in the package design, operating procedures, acceptance tests and maintenance program or contents of the package were requested.
The staff reviewed the documents referenced in the Certificate of Compliance and determined that the package application was complete. Holtec International Report No. HI-2146214, Safety Analysis Report on the HI-STAR 190 Package, Revision 3, is an updated, consolidated document, containing all information germane to the CoC; therefore, a consolidated application is not required for this renewal request pursuant to Title 10 of the Code of Federal Regulations (10 CFR) Section 71.38(c).
CONDITIONS Condition No. 13 extends the previous revision of the certificate by approximately one year.
Condition No. 14 has been revised to extend the CoC expiration date to August 31, 2027.
CONCLUSION Based on the statements and representations in the application, as supplemented, and the conditions listed above, the staff concludes that the Model No. HI-STAR 190 package design has been adequately described and evaluated and that the package meets the requirements of 10 CFR Part 71.
Issued with Certificate of Compliance No. 9373, Revision No. 2.