ML22202A025
| ML22202A025 | |
| Person / Time | |
|---|---|
| Site: | 07201015 |
| Issue date: | 07/22/2022 |
| From: | Storage and Transportation Licensing Branch |
| To: | NAC International |
| BWHITE NMSS/DFM/STLB 3014156577 | |
| Shared Package | |
| ML22202A020 | List: |
| References | |
| EPID L-2021-LLA-0150 | |
| Download: ML22202A025 (3) | |
Text
LIST OF EFFECTIVE PAGES Certificate of Compliance No. 1015 B-2 Amendment No. 8 Appendix B B-1........................ Amendment No. 8 B-2........................ Amendment No. 8 B-3........................ Amendment No. 8 B-4....................... Amendment No. 8 B1-1....................... Amendment No. 8 B2-1....................... Amendment No. 8 B2-2....................... Amendment No. 8 B2-3....................... Amendment No. 8 B2-4....................... Amendment No. 8 B2-5....................... Amendment No. 8 B2-6....................... Amendment No. 8 B2-7....................... Amendment No. 8 B2-8....................... Amendment No. 8 B2-9....................... Amendment No. 8 B2-10..................... Amendment No. 8 B2-11..................... Amendment No. 8 B2-12..................... Amendment No. 8 B2-13..................... Amendment No. 8 B2-14..................... Amendment No. 8 B2-15..................... Amendment No. 8 B2-16..................... Amendment No. 8 B2-17..................... Amendment No. 8 B2-18..................... Amendment No. 8 B2-19..................... Amendment No. 8 B2-20..................... Amendment No. 8 B3-1....................... Amendment No. 8 B3-2....................... Amendment No. 8 B3-3....................... Amendment No. 8 B3-4....................... Amendment No. 8 B3-5....................... Amendment No. 8 B3-6....................... Amendment No. 8 B3-7....................... Amendment No. 8 B3-8....................... Amendment No. 8 B3-9....................... Amendment No. 8 B3-10..................... Amendment No. 8 B3-11..................... Amendment No. 8 B3-12..................... Amendment No. 8 B3-13..................... Amendment No. 8
Certificate of Compliance No. 1015 B-4 Amendment No. 8 B 3.0 Design Features.......................................................................................................... B3-1 B 3.1 Site.................................................................................................................. B3-1 B 3.2 Design Features Important for Criticality Control............................................. B3-1 B 3.3 Codes and Standards...................................................................................... B3-2 B 3.4 Site Specific Parameters and Analyses........................................................... B3-7 B 3.5 CANISTER HANDLING FACILITY (CHF)..................................................... B3-11 Table B3-1 List of ASME Code Exceptions for the NAC-UMS SYSTEM......................... B3-3 Table B3-2 Load Combinations and Service Condition Definitions for the CANISTER HANDLING FACILITY (CHF) Structure................................... B3-13
Certificate of Compliance No. 1015 B3-2 Amendment No. 8 B 3.3 Codes and Standards The American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code), 1995 Edition with Addenda through 1995, is the governing Code for the NAC-UMS CANISTER.
The American Concrete Institute Specifications ACI-349 (1985) and ACI-318 (1995) govern the NAC-UMS CONCRETE CASK design and construction, respectively.
The American National Standards Institute ANSI N14.6 (1993) and NUREG-0612 govern the NAC-UMS TRANSFER CASK design, operation, fabrication, testing, inspection and maintenance.
B 3.3.1 Exceptions to Codes, Standards, and Criteria Table B3-1 lists exceptions to the ASME Code for the design of the NAC-UMS SYSTEM.
B 3.3.2 Construction/Fabrication Exceptions to Codes, Standards, and Criteria Proposed alternatives to ASME Code,Section III, 1995 Edition with Addenda, through 1995, including exceptions listed in Specification B3.3.1, may be used when authorized by the Director of the Office of Nuclear Material Safety and Safeguards or designee. The request for such alternatives should demonstrate that:
- 1. The proposed alternatives would provide an acceptable level of quality and safety, or
- 2. Compliance with the specified requirements of ASME Code,Section III, 1995 Edition with Addenda through 1995, would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.
Requests for exceptions shall be submitted in accordance with 10 CFR 72.4.