MEMORANDUM TO:
Greg Oberson, Acting Chief Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:
Donna Williams, Senior Project Manager Advanced Reactor Licensing Branch 1 Division of Advanced Reactors and Non-power Production and Utilization Facilities Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF THE JUNE 8 AND 9, 2022 CLOSED MEETINGS TO DISCUSS SAFETY FEATURES OF THE OKLO DESIGN The U.S. Nuclear Regulatory Commission (NRC) held closed meetings on June 8 and 9, 2022, to discuss with Oklo safety features of their advanced reactor design and key regulatory topics.
The closed meeting notice can be found in ADAMS under Accession No. ML22154A455.
This meeting notice was posted on the NRC public website as a closed meeting because the discussion topics are considered proprietary commercial information that should be withheld from public disclosure. Enclosed are the list of participants (Enclosure 1), a detailed meeting overview (proprietary) (enclosure 2), and the meeting slides (proprietary) (enclosure 3).
Docket No. 99902095
Enclosures:
1.
List of Attendees 2.
Meeting overview (proprietary) 3.
Meeting slides (proprietary)
CONTACT: Donna Williams, NRR/DANU/UAL1 August 1, 2022 Signed by Williams, Donn on 08/01/22
ML22201A557 NRR-106 OFFICE DANU/UARL: PM DANU/UARL: BC DANU/UARL: PM NAME DWilliams GOberson DWilliams DATE 7/21/2022 7/27/2022 8/1/2022 U.S. NUCLEAR REGULATORY COMMISSION June 8 and 9, 2022, CLOSED MEETINGS TO DISCUSS OKLO SAFETY FEATURES MEETING ATTENDEES Name Organization June 8 June 9 Donna Williams U.S. Nuclear Regulatory Commission (NRC)
X X
Alexandra Siwy NRC X
x Reed Anzalone NRC X
x Stephen Philpot NRC X
X David Heeszel NRC X
X Jason Schaperow NRC X
X Cliff Munson NRC X
Matthew Thomas NRC X
X Steve Vitto NRC X
Michelle Hayes NRC X
x William Kennedy NRC X
X Jesse Quichocho NRC X
Bruce Musico NRC X
Hosung Ahn NRC x
Michelle Hart NRC X
x Hanh Phan NRC X
Ken Erwin NRC X
Pete Lee NRC X
Kevin Quinlan NRC X
Charles Teal NRC X
Amanda Marshall NRC X
Peyton Daub NRC X
Donald Palmrose NRC X
Trace Orf Oklo X
X Pat Everett Oklo X
X Ross Moore Oklo X
X Amirit Patel Oklo X
X Alex Renner Oklo X
X Caroline Cochran Oklo X
X Emma Redfoot Oklo X
X Lisa Momkes Oklo X
Tyrell Arment Oklo X