Letter Sequence Draft Approval |
|---|
|
|
MONTHYEARML21133A4922021-05-21021 May 2021 NRC 897 Topical Report Withholding Determination Form Westinghouse Topical Report WCAP-18546-P/NP Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other ML21133A4932021-05-21021 May 2021 NRC 898 Completeness Determination Form Westinghouse Topical Report WCAP-18546-P/NP Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other ML21133A4942021-05-25025 May 2021 Email Completeness Form and Proprietary Information Withholding Determination Form Westinghouse Topical Report WCAP-18546-P/NP Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other PMNS20210806, Closed post-submittal Virtual Meeting with Westinghouse Electric Company to Discuss Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel2021-06-11011 June 2021 Closed post-submittal Virtual Meeting with Westinghouse Electric Company to Discuss Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Request ML21190A1522021-07-13013 July 2021 Summary of Closed Post Submittal Meeting for the Westinghouse Electric Company Topical Report WCAP-18546-P/NP, Westinghouse Axiomr Cladding for Use in Pressurized Water Reactor Fuel Project stage: Meeting ML21271A1122021-10-0707 October 2021 Cover Letter with Enclosure October 18-21, 2021, Regulatory Audit Plan for the Westinghouse Electric Company Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other ML21351A2852021-12-21021 December 2021 Email Requests for Additional Information for the Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: RAI ML22096A2482022-04-11011 April 2022 NRC 897 Withholding Determination Form for Westinghouse Supplement to WCAP-18546-P/WCAP-18546-NP, Westinghouse Axiomr Cladding for Use in Pressurized Water Reactor Fuel, to Extend Applicability to Include Westinghouse Advanced Doped Pellet Project stage: Other ML22096A2292022-04-11011 April 2022 NRC 897 Withholding Determination Form for Submittal of Responses to Requests for Additional Information on Westinghouse Topical Report 18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: RAI ML22096A2342022-04-13013 April 2022 Email for Proprietary Information Withholding Determination Forms RAI Responses and Supplement for WCAP-18546-P/NP Westinghouse Axiomr Cladding for Use in Pressurized Water Reactor Fuel and RAI Responses Project stage: RAI ML22194A8752022-09-0202 September 2022 Transmittal Email for the U.S. NRC Draft Safety Evaluation for Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Draft Approval ML22297A2602022-10-21021 October 2022 Comments and Proprietary Markings on the Draft Safety Evaluation for Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel (Proprietary) Project stage: Request ML22320A6852022-12-16016 December 2022 Non-Proprietary Enclosure 1 - U.S. NRC Final Safety Evaluation for Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Approval ML22306A2722022-12-16016 December 2022 Cover Letter for the U.S. NRC Final Safety Evaluation for Westinghouse Topical Report WCAP-18546-P/NP, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Approval ML23111A0902023-04-28028 April 2023 U.S. Nuclear Regulatory Commission Form 897 Topical Report Withholding Determination for Westinghouse Electric Company Topical Report WCAP-18546-P/NP-A, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other ML23111A0962023-04-28028 April 2023 U.S. Nuclear Regulatory Commission Form 896 - a Topical Report Verification for Westinghouse Electric Company Topical Report WCAP-18546-P/NP-A, Westinghouse Axiom Cladding for Use in Pressurized Water Reactor Fuel Project stage: Other 2021-07-13
[Table View] |
Text
From:
Lenning, Ekaterina To:
Zozula, Camille T.
Cc:
Harper, Zachary S; James, Lois; Chang, Richard; Krepel, Scott; Parks, Benjamin
Subject:
U.S. Nuclear Regulatory Commission Draft Safety Evaluation for Westinghouse Electric Company Topical Report WCAP-18546-P/NP, "Westinghouse AXIOM Cladding for Use in Pressurized Water Reactor Fuel" Date:
Friday, September 02, 2022 11:28:00 AM Ms. Camille Zozula Manager, Infrastructure & Facilities Licensing Westinghouse Electric Company
Ms. Zozula,
By letter dated March 31, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21090A110), Westinghouse Electric Company (Westinghouse) submitted to the U.S. Nuclear Regulatory Commission (NRC) a request for review and approval of Topical Report (TR) WCAP-18546-P/NP, Westinghouse AXIOM Cladding for Use in Pressurized Water Reactor Fuel (Proprietary/Non-Proprietary). Based on its review of the information submitted in the TR, the NRC staff finds the TR acceptable for referencing subject to the limitations specified in the TR, and in the NRC safety evaluation (SE).
A copy of the draft SE has been placed in the box.com folder.Zachary Harper, Westinghouse, has been given access to the folder. The draft SE is being provided for a proprietary information review.
Pursuant to Section 2.390 of Title 10 of the Code of Federal Regulations (10 CFR), we have determined that the draft SE may contain proprietary information.If you believe that any information in the draft SE is proprietary, please identify such information line-by-line and define the basis pursuant to the criteria of 10 CFR 2.390.Please use bold brackets and yellow highlight to identify any [proprietary information].
Your response must be via a letter from an authorized individual.Please provide your response within 20 working days. The final SE will be issued after making any necessary changes.
Note that at this stage of the process, the NRC staff has completed its review of the submitted information and will not entertain technical arguments.The staff conclusions and conditions will not change unless new information is provided on the docket that was not available during our review.If Westinghouse would like to discuss the draft SE in detail, we can do that in a noticed meeting.
The draft SE has been placed in ADAMS.The draft SE was made an Official Agency Record and declared as nonpublic because it may contain proprietary information.This email will be placed into ADAMS, made an Official Agency Record and declared public.
If you have any questions, please feel free to contact me at 301-415-3151 or by email at Ekaterina.Lenning@nrc.gov.
Ekaterina Lenning, Project Manager Licensing Projects Branch
Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission
Docket No.: 99902038
ML22194A872 (Package)
ML22194A875 (Email)
ML22194A952 (Proprietary Draft SE)
OFFICE NRR/DORL/LLPB/
PM NRR/DORL/
LLPB/LA NRR/DSS/SFNB/
BC OGC/NLO NRR/DORL/LLPB/
BC (A)
NAME ELenning DHarrison SKrepel MWoods RChang (LJames for)
DATE 07/14/2022 7/19/2022 7/20/2022 9/01/2022 9/02/2022