ML22175A202
| ML22175A202 | |
| Person / Time | |
|---|---|
| Issue date: | 06/30/2022 |
| From: | Pamela Noto Office of Nuclear Material Safety and Safeguards |
| To: | |
| Malone, Tina | |
| References | |
| NUREG/BR-0058 | |
| Download: ML22175A202 (21) | |
Text
APPENDIX K 1
MONETARY VALUATION OF NONFATAL CANCER RISK FOR USE IN COST-BENEFIT ANALYSIS 2
K-iii NUREG/BR-0058, Rev. 5, App. K, Rev. 0 TABLE OF CONTENTS 1
2 LIST OF FIGURES.................................................................................................................. K-iv 3
LIST OF TABLES.................................................................................................................... K-iv 4
ABBREVIATIONS AND ACRONYMS..................................................................................... K-v 5
K.1 PURPOSE...................................................................................................................... K-1 6
K.2 BACKGROUND............................................................................................................. K-2 7
K.3 VALUE OF A STATISTICAL ILLNESS......................................................................... K-4 8
K.3.1 Selection of Illnesses......................................................................................... K-5 9
K.3.2 Valuation Methodology and Data Sources........................................................ K-6 10 K.3.2.1 Cohort Definition................................................................................ K-7 11 K.3.2.2 QALY Gain Models............................................................................ K-7 12 K.3.2.3 Valuing of Morbidity Risk Reductions............................................... K-10 13 K.3.3 Results............................................................................................................. K-11 14 K.4 REFERENCES............................................................................................................. K-13 15 16
K-iv NUREG/BR-0058, Rev. 5, App. K, Rev. 0 LIST OF FIGURES 1
2 Figure K-1 QALYs Gained From an Averted Illness................................................................ K-5 3
Figure K-2 Breast Cancer Model State Transition Diagram..................................................... K-8 4
Figure K-3 NSCLC Model State Transition Diagram............................................................... K-9 5
Figure K-4 Stage at Diagnosis MappingLung Cancer........................................................ K-10 6
7 LIST OF TABLES 8
9 Table K-1 QALYs Gained from Averted Case of Nonfatal Cancers....................................... K-10 10 Table K-2 Value per QALY.................................................................................................... K-11 11 Table K-3 Value per Nonfatal Cancer Case........................................................................... K-11 12 Table K-4 Morbidity Risk Conversion Factors........................................................................ K-12 13 14
K-v NUREG/BR-0058, Rev. 5, App. K, Rev. 0 ABBREVIATIONS AND ACRONYMS 1
2 ADAMS Agencywide Documents Access and Management System 3
BEIR Biological Effects of Ionizing Radiation 4
BLS Bureau of Labor Statistics 5
EPA U.S. Environmental Protection Agency 6
Gy gray 7
HRQL health-related quality of life 8
ICRP International Commission on Radiological Protection 9
IOM Institute of Medicine 10 NRC U.S. Nuclear Regulatory Commission 11 NSCLC nonsmall cell lung cancer 12 QALY quality-adjusted life year 13 UNSCEAR United Nations Scientific Committee on the Effects of Atomic Radiation 14 VSI value of a statistical illness 15 VSL value of a statistical life 16 WTP willingness to pay 17 18
K-1 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K.1 PURPOSE 1
2 This appendix provides guidance for valuing morbidity risks from radiation exposure for use in 3
cost-benefit analysis at the U.S. Nuclear Regulatory Commission (NRC). Exposure to radiation 4
can increase the chances of developing nonlethal health outcomes resulting in health costs and 5
impacts to quality of life. To account for these impacts in cost-benefit analysis, these changes 6
in morbidity risks are monetized to the extent practicable.
7
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-2 K.2 BACKGROUND 1
2 The dollar per person-rem conversion factor in the 1995 version of NUREG-1530, 3
Reassessment of the NRCs Dollar Per Person-Rem Conversion Factor Policy (NRC, 1995), is 4
based on the recommendations in the International Commission on Radiological Protection 5
(ICRP) Publication 60, 1990 Recommendations of the International Commission on 6
Radiological Protection, issued 1991 (ICRP, 1991). This ICRP publication provided a 7
recommended nominal risk coefficient, which accounted for the probability of occurrence of a 8
harmful health effect and a judgment of the severity of the effect. The ICRP nominal risk 9
coefficient captures the total detriment, which represents both the probability of a harmful health 10 effect and a judgment of its severity. The components of detriment included in the ICRP 11 nominal risk coefficient are the probability of fatal cancer, the weighted probability of nonfatal 12 cancer, the weighted probability of severe hereditary effects, and the length of life lost. The 13 dollar per person-rem conversion factor is calculated as the product of the ICRP nominal risk 14 coefficient and the value of a statistical life (VSL) in its dollar per person-rem conversion factor 15 to provide a monetary value of the health risks resulting from radiation exposure.
16 17 Since the publication of the 1995 dollar per person-rem guidance, both the ICRP and the 18 U.S. Environmental Protection Agency (EPA) have revised their cancer risk coefficient 19 estimates based on updated information. Specifically, in 2006, the National Academies of 20 Sciences published the Health Risks from Exposure to Low Levels of Ionizing Radiation 21 Biological Effects of Ionizing Radiation (BEIR) VII Phase 2, commonly referred to as the 22 BEIR VII report (National Research Council, 2006). This study was conducted to advise the 23 U.S. Government on the relationship between exposure to ionizing radiation and human health 24 and was supported by several Federal agencies, including the NRC. The models 25 recommended in the BEIR VII report serve as the basis for the estimates of radiogenic cancer 26 risk calculated by the EPA1 and published in EPA 402-R-11-001, Radiogenic Cancer Risk 27 Models and Projections for the U.S. Population, issued 2011 (EPA, 2011).
28 29 The NRC issued Revision 1 to NUREG-1530 in February 2022 (NRC, 2022). In Revision 1, the 30 NRC adopted the EPAs cancer mortality risk coefficient, which is based on the BEIR VII report 31 and is specific to the U.S. population. Only the cancer mortality risk from radiation exposure is 32 monetized in NUREG-1530. This necessitates the establishment of a method to monetize 33 morbidity (nonfatal) risks for use in cost-benefit analysis.
34 35 Valuing morbidity risk reductions presents several unique challenges. Unlike mortality, which 36 has a single endpoint (i.e., death), morbidity effects can vary by the extent of severity, duration, 37 and the perceived dread associated with symptoms and treatment. These differences have 38 resulted in a scarcity of willingness-to-pay (WTP) estimates for morbidity risks. To identify an 39 appropriate method for valuing morbidity risks, the NRC conducted a literature review of Office 40 of Management and Budget guidance and Federal and international agency practices for 41 estimating the economic valuation of nonfatal health risks. SECY-20-0074, Valuing Nonfatal 42 Cancer Risks in Cost-Benefit Analysis, issued August 2020 (NRC, 2020), documents this 43 review.
44 45 1
The EPA estimates the risk from low-level ionizing radiation as part of its responsibilities for regulating environmental exposures and as part of its Federal guidance role in radiation protection (EPA, 2011). The EPA is assigned the responsibility for developing guidance for all Federal agencies in the formulation of radiation protection standards (National Research Council, 1999).
K-3 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 This appendix provides the technical bases for valuing morbidity from averted radiation-induced 1
illnesses for staff use in the preparation of NRC cost-benefit analyses.
2 3
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-4 K.3 VALUE OF A STATISTICAL ILLNESS 1
2 The value of a statistical illness2 (VSI) is used to monetize the benefit of a reduction in the risk 3
of developing nonfatal cancer and is similar to the more commonly used metric for mortality risk 4
values, the VSL. The VSI uses the marginal rate of substitution between small changes in 5
illness risk and wealth to determine the equivalent monetary value of a statistical illness averted, 6
for the sole purpose of describing the likely benefits of a regulatory action. This method is not 7
applicable for estimating an identifiable individual or very large reductions in individual risks or 8
large dose rate scenarios.
9 10 The VSI is estimated using a cost-effectiveness analysis measure known as quality-adjusted life 11 year (QALY). QALYs are used extensively in medical decisionmaking as a measure to compare 12 the nonmonetary benefit provided by various medical interventions and as a general measure of 13 disease burden in health policy (IOM, 2006). The QALY remaining for a hypothetical individual 14 living in a given health state is estimated as the product of two components: a utility3 weight 15 representing quality of life, and the length of time living in that particular state of health.
16 17 Figure K-1 illustrates the QALYs remaining for two health outcomes, one with a disease and 18 one disease free. The health utility weight, often referred to as a health-related quality of life 19 (HRQL) weight, is defined on the y-axis. It is indexed between 0 and 1, where 1 represents full 20 health and 0 represents a state equivalent to death (Jia et al., 2016). The time lived in each 21 state is represented on the x-axis. Thus, the QALYs remaining for each case can be estimated 22 as the area under the health profile represented by the respective curves.
23 2
The VSI approximates societys WTP for small changes in nonfatal cancer risks. Conceptually, it represents an average individuals marginal rate of substitution between wealth and small risk reductions. Importantly, this term does not place a value on the pain and suffering of any specific individual who develops an illness.
Instead, it reflects the WTP for small risk reductions from an individuals baseline, such as a 1 in 100,000 reduction in the chance of developing nonfatal cancer.
3 In health economics, utilities may be defined as cardinal values that represent the strength of an individuals preference for specific health outcomes (Tolley, 2009).
K-5 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 1
Figure K-1 QALYs Gained from an Averted Illness 2
Figure K-1 shows that the QALYs gained from an averted case of an illness can be 3
approximated by the difference in areas under the with disease curve and the without 4
disease curve, as illustrated by the shaded portion. This framework is used to estimate the 5
QALYs gained, which is then used to monetize the benefits associated with an averted case of 6
nonfatal cancer.
7 8
K.3.1 Selection of Illnesses 9
10 Cancers pose a significant risk from low-level chronic radiation exposure. The selection of 11 cancer types for valuation is based on the lifetime attributable risk projections for cancer 12 incidence reported in Table 3-15 of EPA 402-R-11-001. According to this EPA report, breast 13 cancer and lung cancer are projected to have the highest gender-averaged lifetime attributable 14 risk in cases per 10,000 person-gray (Gy) among solid cancers from low-dose, low-linear 15 energy transfer, uniform whole body irradiation. These two cancer types also are among the 16 most prevalent in the United States (Siegel, Miller, and Jemal, 2020).
17 18 While studies have demonstrated that radiation can induce hereditary effects in plants and 19 animals, these effects have not been seen in human studies. Given the absence of genetic 20 effects observed in children of atomic bomb survivors, the largest study population of individuals 21 exposed to moderate acute doses, researchers are unable to reliably estimate the risk 22 coefficient for heritable effects. Nonetheless, both the Committee on the Biological Effects of 23 Ionizing Radiation (BEIR) and the United Nations Scientific Committee on the Effects of Atomic 24 Radiation (UNSCEAR) have attempted to deduce human hereditary effect estimates indirectly.
25 According to a 2001 UNSCEAR report, the total hereditary risk coefficient is estimated at 26 approximately one-tenth that of fatal cancer (UNSCEAR, 2001). The BEIR VII report estimates 27 that, at low or chronic doses of low-linear energy transfer radiation, the genetic risks are very 28 small compared to the baseline frequencies of genetic diseases in the population. Further, 29 ICRP Publication 103, The 2007 Recommendations of the International Commission on 30
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-6 Radiological Protection, issued 2007 (ICRP, 2007), provides a lower weighting factor for 1
heritable effects after exposure to radiation due to a lack of observed effects.
2 3
While evidence shows that radiation can induce noncancer health effects (i.e., cataracts and 4
cardiovascular disease), there is no evidence of an increase in the risk of these effects from 5
low-level exposures (EPA, 2011).
6 7
This appendix focuses solely on the risks associated with low-level chronic exposures. It does 8
not consider deterministic health effects from acute high doses.
9 10 K.3.2 Valuation Methodology and Data Sources 11 12 One of the principal challenges of applying the monetized QALY method to cancer illnesses is in 13 developing a representative temporal illness profile that fully captures the potential disease 14 states that an individual might experience. Cancer progression, like cancer initiation, is believed 15 to be largely a stochastic process (Frei et al., 2020) in which metastasis involves some 16 randomness and uncertainty. This means that an individual diagnosed with cancer has some 17 likelihood of progressing through different stages or states that may have very different impacts 18 on quality of life, but it is impossible to know with certainty in which state they will be at any 19 future point in time. This stochastic property of carcinogenesis is well-suited to be modeled as a 20 Markov process (Tan, 2015). In a Markov process, the state of a system in any period of time 21 cannot be determined with certainty, but transition probabilities can describe the manner in 22 which the system may transition from one period to the next (Anderson et al., 2018). A Markov 23 chain is a mathematical model used to describe this process in discrete time steps 24 (Manning et al., 2008). These models are used extensively in cost-effectiveness analysis and 25 medical decisionmaking to simulate large patient cohorts over their lifetimes and therefore 26 estimate long-term health outcomes (Graves et al., 2016).
27 28 In the fields of economics and decision theory, expected utility theory provides a way of 29 quantifying an individuals preferences over future states that have uncertain outcomes called 30 gambles. Under certain expected utility theory axioms4 for rational behavior, a utility function 31 exists such that the utility associated with a gamble is the statistical expectation of an 32 individuals valuations of the outcomes of that gamble. This is calculated by taking the weighted 33 average of all possible outcomes, with the weights being assigned by the likelihood, or 34 probability, that any particular event will occur. An example from Nechyba (2017) assumes that 35 there are two potential future states, a bad state and a good state, where the probability of 36 the bad state occurring is represented by. Given that the assumptions of expected utility 37 theory are satisfied, there exists a utility function of the form:
38 39
= + (1 )
40 41 where:
represents the utility associated with the bad state and 42 represents the utility associated with the good state.
43 44 This function, referred to as a von Neumann-Morgenstern expected utility function, expresses 45 an individuals utility of facing a particular gamble. Applying this framework, the expected 46 health-related utility for an individual who is diagnosed with cancer at a future date can be 47 4
See Machina and Viscusi (2014) for further discussion of expected utility and the set of axioms that underlie this theory.
K-7 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 defined as the average of the HRQL utility associated with the various potential health states 1
weighted by the probability of being in each state during that time period.
2 3
The expected QALYs5 gained by an averted case of cancer is estimated by using a first-order 4
Markov chain to define the health state probability distributions over time. A weighted average 5
HRQL is used to estimate the expected utility associated with each remaining year of life.
6 Cohort-based Markov state transition models based on existing cost-effectiveness analysis 7
model specifications were used to evaluate the long-term impact that a cancer diagnosis has on 8
patient quality of life. Simulated cohorts of individuals newly diagnosed with either nonsmall cell 9
lung cancer (NSCLC) or breast cancer were constructed to model how the cohort transitioned 10 between states over time. The resulting state probability distributions for each year of life 11 following diagnosis were then combined with health utility information from published 12 cost-effectiveness analysis studies and with current VSL estimates to monetize a statistical case 13 of the illness.
14 15 K.3.2.1 Cohort Definition 16 17 For both public and occupational exposures, the NRC expects that the median age of the 18 affected population is similar. According to the 2020 Labor Force Statistics from the Current 19 Population Survey (BLS, 2021), the median age of workers in the electric power generation 20 sector was estimated to be 44.6 years and the median age of the total U.S. workforce was 21 42.5 years. The median age of the U.S. population was estimated to be 38.5 years using the 22 middle assumptions in the U.S. Census Bureaus most recently released demographic analysis 23 (U.S. Census Bureau, 2020). The latency period of 13.6 years was chosen6 and combined with 24 a median age of the U.S. population of 38.5 years, resulting in an approximate age of 50 years 25 for the model cohort. This is much younger than the median age at diagnosis for breast cancer 26 and NSCLC, which are around 62 and 70 years old, respectively. For this reason, both cancer 27 types are used in calculating the value of morbidity.
28 29 K.3.2.2 QALY Gain Models 30 31 Baseline Case 32 33 In estimating the number of QALYs saved by an avoided case of cancer, two approximations 34 are made: (1) the remaining QALYs for an individual without disease and (2) the remaining 35 QALYs for an individual with disease. The remaining QALYs for the case without disease is not 36 equal to the number of life years remaining because survey data show that HRQL tends to 37 decline with age (Hanmer et al., 2016). The scenario with the absence of the disease is 38 referred to as the baseline case.
39 40 5
As described in Section K.3, QALYs remaining for an individual are the product of the health utility weight by the time spent experiencing that health utility. Given that each period of analysis is 1 year, the QALY associated with that year is equal to the HRQL experienced for that year. Thus, the QALYs remaining for an individual is the sum of the expected HRQL for each year of life remaining.
6 The age at diagnosis selected for this cohort is based on a review of the literature on radiation-induced cancer latency. The data from secondary malignancies in radiotherapy patients indicate a minimum latency period for induction of solid tumors of 10 years or more (Hall and Giaccia, 2012; Goske et al., 2014).
According to the ICRP, the minimum and mean latent period for most solid cancers is 10 years and greater than 20 years, respectively (ICRP, 2001). One analysis looked specifically at a low-dose subcohort of the Japanese atomic bomb survivors and found a latency period of 13.60 years for lung cancer (Dropkin, 2007).
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-8 For the baseline case, only two states are defined: alive and dead. Age-dependent conditional 1
probabilities of dying for healthy individuals represent time-dependent transition probabilities 2
and are taken from the Centers for Disease Control and Prevention Life Tables for the most 3
recent year that data are available (Arias, 2019). The age-related health utility weights are 4
taken from Hanmer et al. (2016), which estimated nationally representative age and gender 5
stratified HRQL scores for the U.S. population based on data from the Medical Expenditure 6
Panel Survey (AHRQ, 2018). The expected QALYs remaining for the baseline case were 7
computed as the likelihood of survival for each year of life remaining for a 50-year-old times the 8
gender-averaged HRQL score associated with that year. Summing these values over the 9
remaining life years represents the expected QALYs remaining for a 50-year-old for the baseline 10 case.
11 12 Breast Cancer Markov Model 13 14 The QALYs remaining for an individual diagnosed with breast cancer are estimated using a 15 Markov model based on an evaluation of the cost-effectiveness of different predictive assay 16 strategies on the outcomes of breast cancer patients (Blank et al., 2010). The model sorts 17 patients into five distinct health states, as shown in Figure K-2, including a single absorbing 18 state of death.
19 20 21 Figure K-2 Breast Cancer Model State Transition Diagram 22 Source: Adapted from Blank et al. (2010) 23 24 The health utility estimates for each state are taken from those reported in Blank et al. (2010).
25 26 Lung Cancer Markov Model 27 28 The Lung Cancer Markov model is based in part on the postdiagnosis model described in Hofer 29 et al. (2018), which evaluated the efficacy of lung cancer screening programs in Germany. This 30 model consists of 10 possible health states, including a single absorbing state of death.
31 Figure K-3 shows the model structure and the possible transitions between states. Initially, 32 patients are placed into one of the treatment states (outlined by a dashed line in Figure K-3).
33 Transition probabilities are taken from those reported in Hofer et al. (2018) and converted to 34 1-year transition probabilities from their initial 3-month cycle length using the approach in Ho 35 Death Disease Free Metastasis Local Recurrence Regional Recurrence
K-9 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 and Yi (2004). Because data are not available to develop age-specific transition probabilities, 1
the model assumes that age does not affect the speed of progression between stages. The 2
NRC makes the same assumption and uses time-independent transition probabilities for 3
modeling lung cancer using a Markov model.
4 5
6 Figure K-3 NSCLC Model State Transition Diagram 7
Source: Adapted from Hofer et al. (2018) 8 9
To construct an initial cohort vector representative of U.S.-based NSCLC patients, the stage at 10 diagnosis distribution for newly diagnosed NSCLC patients was obtained from the National 11 Cancer Database7 using 2016 data, the most recent year of diagnosis available. Patients are 12 binned into initial treatment states by mapping the stage at diagnosis from the National Cancer 13 Database to the stages delineated in the postdiagnosis model. The unknown stages are 14 excluded, and the percentages are normalized to provide the initial distribution, as shown in 15 Figure K-4.
16 17 7
The National Cancer Database is a nationwide oncology outcomes database sponsored by the American College of Surgeons and the American Cancer Society. This database contains hospital registry data from over 1,500 facilities representing approximately 70 percent of newly diagnosed cancer cases in the United States (NCDB, 2021).
Initial States Death Surgery Chemo +
Radio Surgery +
Chemo +
Radio Surgery +
Chemo Palliative care After care II After care I
After care III After care IV
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-10 National Cancer Database Lung Cancer Model Stage Stage 0
0.42%
I 32%
I 30.36%
II 9.5%
II 9.26%
IIIa 9.3%
III 18.22%
IIIb 9.3%
IV 39.25%
IV 40.3%
Totala 97.51%
Total 100%
a Unknown diagnosis stages are excluded and the adjusted total is used to normalize the Lung Cancer Model stage 1
percentages.
2 3
Figure K-4 Stage at Diagnosis Mapping - Lung Cancer 4
The stage distributions mapped in Figure K-4 are used in combination with the distribution of 5
treatments by lung cancer stage reported in Hofer et al. (2018) to sort the cohort into the 6
treatment states to form the initial states vector. This model simulates yearly transitions of 7
patients between states for up to 60 years. Each year, the proportion of patients in each state is 8
used to weight the HRQL index for those health states to develop an annual weighted HRQL.
9 10 QALY Gained from Averted Cancers 11 12 The QALYs gained from an averted case of cancer are computed by subtracting the annual 13 weighted HRQL estimates of the with cancer case from that of the baseline model. Table K-1 14 presents the QALYs gained from an averted case of nonfatal breast cancer and lung cancer.
15 16 Table K-1 QALYs Gained from Averted Case of Nonfatal Cancers 17 Nonfatal Cancer QALYs Gained Per Case Breast cancer 0.89 Lung cancer 1.62 18 The expected QALYs gained are because of averted morbidity only and do not reflect any 19 potential life years gained or lost from averted cancer mortality.
20 21 K.3.2.3 Valuing of Morbidity Risk Reductions 22 23 Willingness to pay (WTP) refers to the maximum amount of money an individual would be 24 willing to pay to obtain a benefit or avoid a detriment. As described in SECY-20-0074, WTP is 25 widely accepted as the preferred method for valuing the benefits of government regulation and 26 for valuing changes in health risk. High-quality WTP estimates are not available for many 27 morbidity risks, which require the use of proxy measures. Analysts should first review the 28 literature to determine whether WTP estimates of reasonable quality are available for morbidity 29 risks similar to those that would be addressed in the cost-benefit analysis.8 If such estimates 30 are available, the WTP values should be adjusted for inflation to reflect the time that has 31 8
Possible sources to search for potential WTP studies include bibliographic databases (e.g., American Economic Association EconLit Web site (http://www.aeaweb.org/econlit/index.php) and Environmental Valuation Reference Inventory Web site (https://www.evri.ca/en)).
K-11 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 elapsed since the WTP studies were conducted and for changes in real income using the 1
methods discussed in NUREG-1530, Revision 1. After the WTP estimate is inflated to the 2
common dollar year used in the analysis, the value of the averted nonfatal cancer is equal to:
3 4
=
5 6
If high-quality WTP estimates are not available, the analyst should apply values that combine 7
estimates of the results with estimates of the monetary value per QALY. The monetary value 8
per QALY gained is computed by dividing the current estimate of the VSL by the remaining 9
expected QALYs of an individual of the average age (40 years old) from the underlying VSL 10 studies.
11 12 The resulting expected QALYs remaining for an average individual aged 40 years is 13 33.217 QALYs. The low, best, and high VSL values are divided by the future expected QALYs, 14 33.217 QALYs, to provide a range of dollar per QALY values for monetizing health detriment as 15 shown in Table K-2.
16 17 Table K-2 Value per QALY 18 Estimate VSL a (2014 dollars)
Value per QALY (2014 dollars) b Low
$4,500,000
$140,000 Best
$9,000,000
$270,000 High
$13,000,000
$390,000 a The VSL estimates are from NUREG-1530, Revision 1, Table 3. For analyses that use a different dollar year, the 19 VSL estimates need to be adjusted to reflect inflation and real income growth, as discussed in NUREG-1530, 20 Revision 1.
21 b The value per QALY is calculated by dividing the respective VSL estimates by the expected QALYs gained and 22 rounded to two significant figures.
23 24 K.3.3 Results 25 26 Based on this modeling, the NRC uses the values provided in Table K-3 as the bases to value a 27 nonspecific radiation-induced cancer and uses the low estimate based on the breast cancer 28 model, the average of the estimates for the best estimate, and the high lung cancer model 29 estimate for the high estimate.
30 31 Table K-3 Value per Nonfatal Cancer Case 32 Estimate Value per QALY (2014 dollars)
QALYs Gained Value per Nonfatal Cancer (2014 dollars)
Low
$140,000 0.89
$130,000 Best
$270,000 1.26
$340,000 High
$390,000 1.62
$630,000 33 The NRC acknowledges that there may be unique circumstances for which other dollar 34 conversion factors may warrant consideration, such as for environmental justice. For example, 35
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-12 doses to a population whose age distribution is not representative of the general population 1
could be subject to a different risk coefficient because health risks are directly related to the age 2
distribution of the affected population. The analyst could include alternative valuations in the 3
regulatory analysis to reflect these impacts. To convert the value per nonfatal cancer case to 4
value changes in routine or accident-related exposures requires the use of a nonfatal cancer 5
risk coefficient. As discussed in Section K.2 of this appendix and consistent with the risk 6
coefficient in NUREG-1530, Revision 1, the NRC adopted the nonfatal component of the EPAs 7
cancer mortality risk coefficient in EPA 402-R-11-001 to quantify the change in probability of 8
developing a nonfatal cancer from a change in dose. This value of 5.8x10-4 per person-rem is 9
calculated by subtracting the EPAs mortality cancer risk coefficient of 5.8x10-2 Gy-1 from the 10 cancer incidence risk coefficient of 1.16x10-1 Gy-1 and converting to rem-1 for low-linear energy 11 transfer radiation.
12 13 The morbidity risk conversion factor is the product of the value per nonfatal cancer and the 14 cancer morbidity risk coefficient, which yields the values in Table K-4.
15 16 Table K-4 Morbidity Risk Conversion Factors 17 Estimate Morbidity Risk Conversion Factor (Dollar per Person-Rem) a,b Low 75 Best 200 High 370 a The morbidity risk conversion factor is calculated by multiplying the value per nonfatal cancer estimate by the 18 cancer morbidity risk conversion factor and rounding to two significant figures.
19 b The low and high values represent the range of reasonable estimates and not a confidence interval.
20 21 The dollar per person-rem conversion factors presented in Table K-4 can be added directly to 22 the low, best, and high dollar per person-rem for mortality values presented in Table 3 of 23 NUREG-1530, Revision 1. Summing both the mortality and morbidity dollar per person-rem 24 values provides a total health detriment dollar per person-rem conversion factor as shown in 25 Table K-5 that the analyst can apply directly to the integrated dose averted over the lifetime of 26 the affected facilities, as outlined in Section 5.3.2 of the main body of this NUREG.
27 28 Table K-5 Valuation of Radiation Exposure 29 Estimate Valuation of Radiation Exposure (Dollar per Person-Rem) (2014 Dollars)
Morbidity Valuation a (A)
Mortality Valuation b (B)
Total Valuation c (A + B)
Low
$75
$2,600
$2,700 Best
$200
$5,200
$5,400 High
$370
$7,800
$8,200 a Values from Table K-4 in this appendix.
30 b Values from Table 3 of NUREG-1530, Revision 1.
31
K-13 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K.4 REFERENCES 1
2 Agency for Healthcare Research and Quality (AHRQ), Medical Expenditure Panel Survey, 2018.
3 Agency for Healthcare Research and Quality, Rockville, MD. Content last reviewed 4
August 2018. Available at https://www.ahrq.gov/data/meps.html.
5 6
American Economic Association EconLit Web site http://www.aeaweb.org/econlit/index.php, 7
2022.
8 9
Anderson, D., et al., An Introduction to Management Science: Qualitative Approaches to 10 Decision Making, 15th Ed, Cengage Learning, Inc., Boston, MA, 2018.
11 12 Arias E., J.Q. Xu, United States Life Tables, 2017. National Vital Statistics Reports; Vol. 68 13 No. 7, National Center for Health Statistics, Hyattsville, MD, 2019. Available at 14 https://www.cdc.gov/nchs/data/nvsr/nvsr68/nvsr68_07-508.pdf.
15 16 Blank, P.R., et al., Human epidermal growth factor receptor 2 expression in early breast cancer 17 patients: a Swiss cost-effectiveness analysis of different predictive assay strategies, Breast 18 Cancer Res. Treat. 124, pages 497-507, 2010. Available at https://doi.org/10.1007/s10549-19 010-0862-7.
20 21 Dropkin, G., Low dose radiation and cancer in A-bomb survivors: latency and non-linear dose-22 response in the 1950-90 mortality cohort, Environmental Health 6, 1, 2007. Available at 23 https://doi.org/10.1186/1476-069X-6-1.
24 25 Environmental Valuation Reference Inventory Web site https://www.evri.ca/en, 2022.
26 27 Frei, C., T. Hillen, and A. Rhodes, A stochastic model for cancer metastasis: branching 28 stochastic process with settlement, Mathematical Medicine and Biology: A Journal of the IMA, 29 Volume 37, Issue 2, pages 153-182, June 2020. Available at 30 https://doi.org/10.1093/imammb/dqz009.
31 32 Goske, M.J., et al., Curbing Potential Radiation-Induced Cancer Risks in Oncologic Imaging:
33 Perspectives From the Image Gently and Image Wisely Campaigns, Oncology Journal, 28(3),
34 2014. Available at https://www.cancernetwork.com/view/curbing-potential-radiation-induced-35 cancer-risks-oncologic-imaging-perspectives-image-gently-and-.
36 37 Graves, N., et al., A cost-effectiveness modelling study of strategies to reduce risk of infection 38 following primary hip replacement based on a systematic review, Health Technology 39 Assessment, No. 20.54, Chapter 4, Cost-effectiveness methods, National Institute for Health 40 and Care Research, Southampton, UK, July 2016. Available at 41 https://www.ncbi.nlm.nih.gov/books/NBK374339/.
42 43 Hall, E., and A. Giaccia, Radiobiology for the Radiologist, Wolters Kluwer: Lippincott Williams &
44 Wilkins, Philadelphia, PA, 2012.
45 46
NUREG/BR-0058, Rev. 5, App. K, Rev. 0 K-14 Hanmer, J., et al., Health Condition Impacts in a Nationally Representative Cross-Sectional 1
Survey Vary Substantially by Preference-Based Health Index, Medical decision making: an 2
international journal of the Society for Medical Decision Making, 36(2), 264-274, 2016.
3 Available at https://doi.org/10.1177/0272989X15599546.
4 5
Ho, T., and S. Lee, The Oxford Guide to Financial Modeling, Oxford University Press, Oxford, 6
England, 2004.
7 8
Hofer, F., H.-U. Kauczor, and T. Stargardt, Cost-Utility Analysis of a Potential Lung Cancer 9
Screening Program for a High-Risk Population in Germany: A Modelling Approach, Lung 10 Cancer 124: 189-198, 2018. Available at https://pubmed.ncbi.nlm.nih.gov/30268459/.
11 12 Institute of Medicine (IOM), Valuing Health for Regulatory Cost-Effectiveness Analysis, The 13 National Academies Press, Washington, DC, 2006. Available at https://doi.org/10.17226/11534.
14 15 International Commission on Radiological Protection (ICRP), 1990 Recommendations of the 16 International Commission on Radiological Protection, ICRP Publication 60, Annals of the 17 ICRP 21 (1-3), 1991.
18 19 ICRP, Radiation and your patientA Guide for Medical Practitioners, ICRP Supporting 20 Guidance 2, Annals of the ICRP 31 (4), 2001.
21 22 ICRP, The 2007 Recommendations of the International Commission on Radiological 23 Protection, ICRP Publication 103, Annals of the ICRP 37 (2-4), 2007.
24 25 Jia, H., M. Zack, and W. Thompson, Population-Based Estimates of Decreases in 26 Quality-Adjusted Life Expectancy Associated with Unhealthy Body Mass Index, Public Health 27 Reports 131 (1): 177-184, 2016. Available at https://pubmed.ncbi.nlm.nih.gov/26843684/.
28 29 Machina, M., and W. Viscusi, Handbook of the Economics of Risk and Uncertainty, Elsevier 30 Science, Amsterdam, Netherlands, 2014.
31 32 Manning, C., P. Raghavan, and H. Schütze, Introduction to Information Retrieval, Cambridge 33 University Press, England, 2008.
34 35 National Research Council, Evaluation of Guidelines for Exposures to Technologically 36 Enhanced Naturally Occurring Radioactive Materials, National Academies Press, 37 Washington, DC, 1999.
38 39 National Research Council, Health Risks from Exposure to Low Levels of Ionizing Radiation:
40 BEIR VII Phase 2, The National Academies Press, Washington, DC, 2006. Available at 41 https://nap.nationalacademies.org/catalog/11340/health-risks-from-exposure-to-low-levels-of-42 ionizing-radiation.
43 44
K-15 NUREG/BR-0058, Rev. 5, App. K, Rev. 0 Nechyba, T., Microeconomics: An Intuitive Approach, 2nd ed., Cengage Learning, Inc., Boston, 1
MA, 2017.
2 3
Siegel, R., K. Miller, and A. Jemal, Cancer Statistics, 2020, CA Cancer J Clin 70 (1): 7-30, 4
2020. Available at https://pubmed.ncbi.nlm.nih.gov/31912902/.
5 6
Tan, W., Stochastic Models with Applications to Genetics, Cancers, AIDS and Other 7
Biomedical Systems, 2nd ed., Series on concrete and applicable mathematics, Volume 19, 8
World Scientific Publishing Co., Singapore, 2015.
9 10 Tolley, K., What Are Health Utilities? What Is... ? Series, Hayward Medical Publishing, 11 London, UK, 2009. Available at https://tolleyhealtheconomics.com/wp-12 content/uploads/2014/09/What-are-health-utilities-Final.pdf.
13 14 United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR),
15 Hereditary Effects of Radiation: United Nations Scientific Committee on the Effects of Atomic 16 Radiation, UNSCEAR 2001 Report to the General Assembly, with Scientific Annex, New York, 17 NY, 2001.
18 19 U.S. Bureau of Labor Statistics (BLS), Labor Force Statistics from the Current Population 20 Survey: Household Data Annual Averages, 2021. Accessed March 9, 2021. Available at 21 https://www.bls.gov/cps/demographics.htm.
22 23 U.S. Census Bureau, Census Bureau Releases 2020 Demographic Analysis Estimates, 2020.
24 Accessed March 9, 2021. Available at https://www.census.gov/newsroom/press-25 releases/2020/2020-demographic-analysis-estimates.html.
26 27 U.S. Environmental Protection Agency (EPA), EPA Radiogenic Cancer Risk Models and 28 Projections for the U.S. Population, EPA 402-R-11-001, Washington, DC, 2011.
29 30 U.S. Nuclear Regulatory Commission (NRC), Reassessment of NRCs Dollar Per Person-Rem 31 Conversion Factor Policy, NUREG-1530, Washington, DC, December 1995. Agencywide 32 Documents Access and Management System (ADAMS) Accession No. ML063470485.
33 34 NRC, Valuing Nonfatal Cancer Risks in Cost-Benefit Analysis, SECY-20-0074, Washington, 35 DC, August 13, 2020. ADAMS Package Accession No. ML20058C219.
36 37 NRC, Reassessment of NRCs Dollar Per Person-Rem Conversion Factor Policy: Final 38 Report, NUREG-1530, Revision 1, Washington, DC, February 2022. ADAMS Accession 39 No. ML22053A025.
40