From:

Cuadrado de Jesus, Samuel Sent:

Friday, June 24, 2022 9:53 AM To:

Drew Peebles Cc:

Beasley, Benjamin; Darrell Gardner; Nicole Schlichting; Delaney Simmons

Subject:

Kairos Hermes CP General Audit Question 5.1-13

Drew, Please see below a new question regarding Section 5.1 of the Hermes PSAR.

Audit Question 5.1-13 Section 5.1.1.1 of the Hermes PSAR references topical report KP-TR-005 for a description of the reactor coolant. Limitations and Conditions of that topical report require an applicant to perform work to ensure coolant properties are in the applicants QA program which Kairos is pursuing (see the regulatory audit summary at ADAMS Accession No. ML21364A106). Provide and discuss the status of the thermophysical property data confirmation for the Flibe coolant.

Let me know when is a good time to discuss this question sometime next week. Maybe we can add this to our general audit meeting on question 5.1-4 next Tuesday at 11 am (EST), on our end we could start the meeting at 10:50am let me know if that works.

Regards, Samuel Cuadrado de Jesús Project Manager Advanced Reactor Licensing Branch (UARL)

Division of Advanced Reactors and Non-Power Production and Utilization Facilities (DANU)

U.S. Nuclear Regulatory Commission Phone: 301-415-2946 Samuel.CuadradoDeJesus@nrc.gov

Hearing Identifier:

KairosPower_CPDocs_Public Email Number:

25 Mail Envelope Properties (SA1PR09MB7392C0AF694923A1F31BB8B888B49)

Subject:

Kairos Hermes CP General Audit Question 5.1-13 Sent Date:

6/24/2022 9:52:55 AM Received Date:

6/24/2022 9:52:00 AM From:

Cuadrado de Jesus, Samuel Created By:

Samuel.CuadradoDeJesus@nrc.gov Recipients:

"Beasley, Benjamin" <Benjamin.Beasley@nrc.gov>

Tracking Status: None "Darrell Gardner" <gardner@kairospower.com>

Tracking Status: None "Nicole Schlichting" <schlichting@kairospower.com>

Tracking Status: None "Delaney Simmons" <simmons@kairospower.com>

Tracking Status: None "Drew Peebles" <peebles@kairospower.com>

Tracking Status: None Post Office:

SA1PR09MB7392.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1165 6/24/2022 9:52:00 AM Options Priority:

Normal Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date: