Text
Department of Energy Washington, DC 20585 June 6, 2022 Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch U.S. Nuclear Regulatory Commission Office of Nuclear Material Safety and Safeguards Two White Flint North - Mail Stop 4 B34 11555 Rockville Pike Rockville, MD 20852-2738
Dear Yoira K. Diaz-Sanabria,
The U.S. Department of Energy (DOE) requests an amendment of U.S. Nuclear Regulatory Commission Certificate of Compliance (CoC) Number 9330, Revision 15 for the Model ATR FFSC package (NRC Docket 71-9330) to authorize an increase of the payload weight limits for the ATR LEU and MURR LEU fuel element configurations from 50 to 59 lb., increase the maximum package weight from 290 to 299 lb. for all configurations, and to increase the maximum fissile mass for the COBRA LEU fuel element configuration from 435.8 to 450.0 g (U-235). The need date for this amendment is December 31, 2022.
The U.S. High Performance Research Reactor (USHPRR) project, under the National Nuclear Security Administrations Convert Program, is working to convert the five remaining USHPRRs from highly enriched uranium (HEU) to low enriched uranium (LEU). In support of this effort, there is a need to ship prototypic, full size LEU-based fuel elements and associated Design Demonstration Elements (DDE) in the ATR FFSC package.
On November 10, 2021, your office issued Revision 15 of CoC No. 9330 to authorize new Fuel Handling Enclosure (FHE) designs for Advanced Test Reactor (ATR) LEU fuel elements and Missouri University Research Reactor (MURR) LEU fuel elements that are different from the ones used for the corresponding HEU fuel elements. DOE has demonstrated in Safety Analysis Report (SAR), Revision 17, by finite element analysis, that the same FHE designs used for HEU fuel elements meet, in both cases, all applicable requirements, making the new FHEs approved in CoC Revision 15 unnecessary.
The application in support of this request, SAR Revision 17, and its supporting documents are enclosed.
Docket 71-9330, June 2, 2022 If you have any questions or need more details, please call at 301-903-5513 or james.shuler@em.doe.gov.
Dr. James M. Shuler Manager, DOE Packaging Certification Program U.S. Department of Energy Office of Packaging and Transportation EM-4.24, 270CC - Rm 3113 Washington, DC 20585
Enclosures:
- 1. Safety Analysis Report, Advanced Test Reactor Fresh Fuel Shipping Container (ATR FFSC),
Revision 17, May 2022, Docket 71-9330
- 2. Selected Sequential Drop Analyses for the ATR FFSC with Heavier LEU Fuel Elements, INL/RPT-22-67296, ECAR-5644, Revision 2, May 2022
- 3. Table of Changes for ATR FFSC SAR Revision 17, ATR FFSC LEU SAR Amendment Revision 17, Docket 71-9330 CC: ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Mr. Pierre M. Saverot, Project Manager Daryn Moorman, NE-ID Eric Woolstenhulme, INL Phil Noss, Orano JAMES SHULER Digitally signed by JAMES SHULER Date: 2022.06.06 14:01:40 -04'00'