Todays Presenters Bruce Watson 2

Karl Sturzebecher Rhex Edwards

17 units in active decommissioning 9 units in SAFSTOR Palisades began planning for decommissioning after notifying the NRC Power Reactors in Decommissioning 3

As of October 2021

Palisades History Mar 24, 1971 -

Operating license issued for Palisades Dec. 1, 2007 -

License Renewed 4

Near-term Developments Palisades shut down on May 20, 2022 Certification of Permanent Cessation of Operations Certification of Permanent Defueled - permanent removal of fuel from reactor Post-Shutdown Decommissioning Activities Report (PSDAR)

Accession No. ML20358A232 5

Post-Shutdown Decommissioning Activities Report (PSDAR) (ML20358A232)

It should contain:

Description of planned decommissioning activities High-level schedule of planned decommissioning activities Site-specific cost estimate for the decommissioning Environmental impacts of decommissioning 6

PSDAR Review Process Normally, the NRC notices receipt of the PSDAR in the Federal Register and requests public comments NRC also schedules a public meeting in the vicinity of the plant to discuss PSDAR &

solicit public comments 7

Permanently Cease Operations by May 2022 Prepare the plant and transfer spent fuel to dry storage by 2025 Safe Storage Period from 2026 to 2035 Complete Radiological Decommissioning by 2041.

Palisades Decommissioning Schedule

& Cost Summary 2022 Decommissioning Trust Fund Balance

$ 552 M in (2020 Dollars)

Estimated cost to complete Radiological Decommissioning

$ 644 M in (2020 Dollars) 8

Palisades PSDAR Comments This public meeting By Mail:

Office of Administration, Mail Stop: TWFN-7-A60M U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 ATTN: Program Management, Announcements and Editing Staff Federal Rulemaking website: http://www.regulations.gov Search for Docket ID NRC-2020-0148 9

Reactor Decommissioning The process of removing a reactor facility safely from the operating mode to a permanent shutdown condition and reducing the residual radioactivity to a level that permits the release of the property for unrestricted use and termination of the license BEFORE AFTER Big Rock Point 10

DECON - Equipment, structures, etc., are removed or decontaminated to a level that permits unrestricted release SAFSTOR - Plant is placed in a safe, stable condition and maintained in this state until it is subsequently decontaminated to levels that permit unrestricted release Decommissioning Options 11

How Long to Decommission?

Under NRC regulations, the process must be completed within 60 years 12

Guiding Principles of Decommissioning Protection of plant &

workers Protection of the public Communications &

outreach with external stakeholders 13

Decommissioning Process - Phases Before Cleanup During Cleanup After Cleanup 14

Ready the plant for decommissioning Move spent nuclear fuel to dry cask storage Submit & update PSDAR 15

Removal of structures & components Soil remediation Radioactive waste shipments 16

Site restoration NRC license termination Spent fuel management 17

Oversight Program After Shutdown Oversight and monitoring conducted over the entire period of decommissioning process Oversight program is described in Inspection Manual Chapters (IMC) 2561, 2202 and 2690 18

Oversight Program After Shutdown Decommissioning inspection program includes both core and discretionary inspections Implementation depends on activities being planned or performed.

Post-Operation Transition Phase Actively Decommissioning - Fuel in Spent Fuel Pool Actively Decommissioning - No Fuel in Spent Fuel Pool SAFSTOR - Fuel in Spent Fuel Pool SAFSTOR - No Fuel in Spent Fuel Pool Final Surveys under way 19

How Does Emergency Planning Change?

Emergency preparedness remains All hazards approach utilized vs. formal pre-planned off-site radiological response plans 20

How will plant security change?

Security controls remain in place Some key features include: intrusion detection and response, assessment of alarms, and off-site assistance, when necessary 21

What Happens to the Spent Fuel?

Removed from spent fuel pool Stored on-site in dry cask storage systems Safety and security programs remain until fuel removed from site 22

NRC ISFSI Inspection Program Inspections performed according to guidance in Inspection Manual Chapter 2690 Inspections cover all activities related to ISFSIs from design to operation 23

NRC ISFSI Inspection Program (contd.)

24

Is the Spent Fuel Pool Safe?

Robust structures Designed to withstand severe natural events Regulated design features &

operational practices implemented to maintain fuel in safe condition 25

How Does the NRC Make Decisions on Post-Shutdown Changes?

Public Involvement on Decommissioning Public meeting to discuss the decommissioning process and the plants PSDAR NRC staff typically provide briefings at meetings of state/citizen decommissioning advisory panels An opportunity for a hearing Public meeting on License Termination Plan 27

NRC References 28

Links for NRC References IMC 2561: Decommissioning Power Reactor Inspection Program RG 1.184: Decommissioning of Nuclear Power Reactors NUREG 1628: Staff Responses to FAQs Concerning Decommissioning of Nuclear Power Reactors NRC Backgrounder: Decommissioning of Nuclear Power Plants NRC YouTube Video on Decommissioning 29

Questions Viktoria.Mitlyng@NRC.GOV 630-829-9662 Prema.Chandrathil@NRC.GOV 630-829-9663 30