MEMORANDUM TO:
William B. Kennedy, Acting Chief Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation FROM:
Lucieann Vechioli, Project Manager Advanced Reactor Licensing Branch Division of Advanced Reactors and Non-Power Production and Utilization Facilities Office of Nuclear Reactor Regulation
SUBJECT:
SUMMARY
OF THE MARCH 17, 2022, PUBLIC MEETING BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION STAFF AND X ENERGY LLC REGARDING THE XE-100 PRINCIPAL DESIGN CRITERIA On March 17, 2022, the U.S. Nuclear Regulatory Commission (NRC) staff held a virtual partially open to the public meeting with representatives from X Energy LLC (X-energy) regarding the Xe-100 reactor design principal design criteria. The meeting notice can be located at Agencywide Documents Access and Management System (ADAMS) Accession No. ML22069A135 and the presentation slides for the open session of the meeting at ML22076A063. The Enclosure provides the list of meeting attendees.
The Xe-100 design approach for the principal design criteria (PDC) is been developed using insights from the Regulatory Guidance (RG) 1.232, Guidance for developing principal design criteria for non-light water reactors, NEI 18-04, Risk-Informed Performance-Based Technology Inclusive Guidance for Non-Light Water Reactors, and NEI 21-07, Technology Inclusive Guidance for Non-Light Water Reactor Safety Analysis Report: For Applicants Utilizing NEI 18-04 Methodology. The purpose of the meeting was for X-energy to present on their approach and to receive feedback from the NRC staff and address it prior submitting the information as a topical report for review and approval.
CONTACT: Lucieann Vechioli, NRR/DANU 301-415-6035 June 6, 2022 Signed by Vechioli, Luciean on 06/06/22
W. Kennedy The discussion included X-energys identified cases in which the modular high-temperature gas-cooled reactor design criteria (MHTGR-DC) from RG 1.232 do not align with the Xe-100 design approach. X-energy representatives stated that justification for the safety case of those instances will be provided as needed.
The NRC staff asked questions and provided insight to X-energy representatives during the discussion. The NRC staff mentioned that it is currently developing a draft document for NEI 21-07 that will be out for public comments in the upcoming months. The NRC staff asked about X-energys approach of having public meetings for every principal design criteria.
X-energy responded that it will request meetings on the chapters that it decides early feedback from the NRC staff would be practical.
Concluding thoughts from the NRC staff included that X-energys approach seems reasonable and that when developing RG 1.232, the NRC staff envisioned a similar approach to the one proposed by X-energy.
X-energy intends to continue to engage with the NRC staff on this and several other topics as part of the pre-application activities for the Xe-100 design. X-energy plans to submit a principal design criteria white paper for the NRC review and subsequently a topical report in the near future.
Project No. 99902071
Enclosure:
List of Attendees
ML22151A263 NRR-052 OFFICE NRR/DANU/UAL1/PM NRR/DANU/UAL1/LA NRR/DANU/UAL1/BC (A)
NRR/DANU/UAL1/PM NAME LVechioli DGreene WKennedy LVechioli DATE 6/2/2022 6/6/2022 6/6/2022 6/6/2022
Enclosure List of Attendees Public Meeting between the U.S. Nuclear Regulatory Commission staff and X Energy LLC Thursday, March 17, 2022 Name Organization Ian Jung U.S. Nuclear Regulatory Commission (NRC)
William Kennedy NRC Michelle Hayes NRC Michael Orenak NRC Lucieann Vechioli NRC Boyce Travis NRC Steven Lynch NRC Eric Oesterle NRC Joseph Sebrosky NRC Travis Chapman X Energy LLC (X-energy)
Steve Vaughn X-energy Ray Wang X-energy Ingrid Nordby X-energy Jon Facemire X-energy Tom Braudt X-energy Brian Froese X-energy Matt Hertel X-energy Shawn Hanvy X-energy Patrick Robinson X-energy Paul Loza X-energy Maggie Staiger X-energy Yvonne Mirowski X-energy Charlotte Geiger X-energy Kevin Pigg X-energy David Alberstein X-energy Eddie Grant X-energy Neil Haggerty X-energy Brian Hallee X-energy Don Gregoire Energy Northwest