|
---|
Category:Agreement States-Regulations Review
MONTHYEARML23135A1582023-05-11011 May 2023 5-11-2023 Receipt of Colorado Proposed Regulations Pertaining to Radiation Control, 6 CCR 1007-1, Part 4 (Standards for Protection Against Radiation) ML22306A1372022-11-0101 November 2022 MD Regulations Supplement 32 ML22298A0072022-10-24024 October 2022 Receipt of North Carolina Proposed Regulations to 2013-1, 2015-2, 2018-2, 2018-3, 2019-1, 2019-2, 2020-1, 2020-3, 2021-1, and 2021-2 ML22244A0042022-08-30030 August 2022 Rats 2019-1 NRC Comparison ML22245A0112022-08-30030 August 2022 NRC Matrix of Revisions ML22243A2132022-08-30030 August 2022 New Mexico Regulations Title 20 Chapter 3 Part 3 (Amended) ML22243A2182022-08-30030 August 2022 New Mexico Regulations Title 20 Chapter 3 Part 5 (Amended) ML22243A2382022-08-30030 August 2022 New Mexico Regulations Title 20 Chapter 3 Part 7 (Amended) ML22243A2402022-08-30030 August 2022 New Mexico Regulations Title 20 Chapter 3 Part 12 (Amended) ML22243A2412022-08-30030 August 2022 New Mexico Regulations Title 20 Chapter 3 Part 15 (Amended) ML22244A0032022-08-30030 August 2022 Rats 2018-3 NRC Comparison ML22244A0062022-08-30030 August 2022 Rats 2019-2 NRC Comparison ML20072L6682022-08-24024 August 2022 Kansas Regulation 28-35-181q ML22208A2542022-07-19019 July 2022 or Cross Reference 2018-3 ML22208A2582022-07-19019 July 2022 or Cross Reference 2020-1 ML22208A2612022-07-19019 July 2022 or Cross Reference 2020-2 ML22193A1742022-07-12012 July 2022 07-12-2022 Letter to R Blackwell Re Louisiana Proposed Regulations to Rats IDS 2018-3, 2019-1, 2019-2, and 2020-1 ML22161A9902022-06-0707 June 2022 TCEQ Cross Reference 2020-3 ML22159A3222022-06-0707 June 2022 CA Cross Reference 2021-2 ML22157A4462022-06-0303 June 2022 New Jersey Regulations Subchapter 59 ML22157A4472022-06-0303 June 2022 New Jersey Regulations Proposed Subchapter 59 ML22157A4182022-06-0202 June 2022 Co Cross Reference 2021-1, Miscellaneous Corrections ML22151A2332022-05-31031 May 2022 Ohio Regulations 3701 1-52-20 ML22151A2312022-05-31031 May 2022 Ohio Regulations 3701 1-49-20 ML22151A2272022-05-31031 May 2022 Ohio Regulations 3701 1-48-23 ML22151A2112022-05-31031 May 2022 Ohio Regulations 3701 1-48-19 ML22136A2252022-05-11011 May 2022 MD Regulations 26.12.01.01 ML22136A0202022-05-10010 May 2022 Wisconsin Subchapter IV 157 35 to 48 Draft ML22136A1762022-05-10010 May 2022 Wisconsin Subchapter Xv 157 9700 to 9718 Draft ML22136A1672022-05-10010 May 2022 Wisconsin Subchapter VII 157 73 Draft ML22136A1532022-05-10010 May 2022 Wisconsin Subchapter VI 157 59 to 72 Draft ML22136A1512022-05-10010 May 2022 Wisconsin Subchapter V 157 51 to 56 Draft ML22136A0382022-05-10010 May 2022 Wisconsin Subchapter III 157 20 to 33 Draft ML22133A2152022-05-10010 May 2022 Wisconsin Subchapter II 157 09-15 Draft ML22133A2092022-05-10010 May 2022 Wisconsin Cross Reference ML22131A2712022-05-0909 May 2022 Georgia Regulations Markup 2021 ML22097A1022022-03-30030 March 2022 Maryland Cross Reference 2020-3 ML22097A1002022-03-30030 March 2022 Maryland Cross Reference 2020-2 ML22097A0972022-03-30030 March 2022 Maryland Cross Reference 2020-1 ML22097A0952022-03-30030 March 2022 Maryland Cross Reference 2019-1 ML22097A0912022-03-30030 March 2022 Maryland Cross Reference 2018-3 ML22097A0782022-03-30030 March 2022 Maryland Responses to NRC Letters 2018-1/2018-2 ML22097A0762022-03-30030 March 2022 Maryland Regulations Supplement 32 Draft ML22067A1962022-03-0808 March 2022 Washington Regulations Ch 246-232 ML22066A3742022-03-0404 March 2022 CRCPD Part T Rationale ML22066A3102022-03-0404 March 2022 CRCPD Part T ML22060A2122022-02-28028 February 2022 Maryland Regulations 26.12.01.01 ML22060A2032022-02-28028 February 2022 Maryland Final Regulations Supplement 31 ML22026A3652022-01-26026 January 2022 CRCPD Part D Draft ML22026A3612022-01-26026 January 2022 CRCPD Part a Draft 2023-05-11
[Table view]Some use of "" in your query was not closed by a matching "". |
Text
Ohio Administrative Code Rule 3701:1-49-20 Personnel monitoring.
Effective: May 23, 2022 (A) The licensee may not permit an individual to act as a logging supervisor or logging assistant unless that person wears a personnel dosimeter at all times during the handling of licensed radioactive materials. Each personnel dosimeter must be assigned and worn by only one individual.
Film badges must be replaced at least monthly and other personnel dosimeters that require replacement must be replaced at least quarterly. All personnel dosimeters must be evaluated at least quarterly or promptly after replacement, whichever is more frequent.
(B) The licensee shall provide bioassay services to individuals using licensed materials in subsurface tracer studies if required by the license.
(C) The licensee shall retain records of personnel dosimeters required by paragraph (A) of this rule and bioassay results for inspection until the director authorizes disposition of the records.
Page 1