Text
Licensee Performance Review https://www.nrc.gov/about-nrc/contactus.html Westinghouse Electric Company Columbia Fuel Fabrication Facility (CFFF)
May 18, 2022 6:00 PM (EDT)
Agenda https://www.nrc.gov/about-nrc/contactus.html NRC Our Mission NRC How We Regulate NRC Performance Review Results CFFF Westinghouse Remarks NRC Adjourn Business Portion NRC Question & Answer with Public NRC Adjourn Meeting 2
Our Mission https://www.nrc.gov/about-nrc/contactus.html 3
How We Regulate Inspections Investigations Allegations Incident
Response
Enforcement Performance Assessment https://www.nrc.gov/about-nrc/regulatory.html 4
IMC 2600 - Fuel Cycle Facility Operational Safety and Safeguards Inspection Program Baseline (Core)
Reactive Supplemental 12 Inspection Areas for Category III Facilities https://www.nrc.gov/about-nrc/contactus.html Inspection Program 5
How We Regulate Inspections Investigations Allegations Incident
Response
Enforcement Performance Assessment https://www.nrc.gov/about-nrc/regulatory.html 6
Licensee Performance Review Process https://www.nrc.gov/about-nrc/contactus.html Plant Events Safety Significance Assessment Reactive Inspections Inspection Follow-up Emergent Performance or Generic Safety Issues Assessment Inspection Program Adjustment Inputs NRC Review Results NRC Response Other NRC Actions
- Enforcement Actions
- Previous Performance
- Safety Significance
- Performance Trends
- Cross Cutting Issues
- Corrective Actions No Performance Issues
- Core Insp. Program
- Inform the Public Area Needing Improvement (ANI)
- Insp. Program Changes
- LPR Frequency
- Inform the Public Or LPR = Licensee Performance Review Performance Areas 7
LPR Results https://www.nrc.gov/about-nrc/contactus.html 2-Year Assessment Period January 1, 2020 - December 31, 2021 8
https://www.nrc.gov/about-nrc/contactus.html 2020 &
2021 Inspection Summary 14 Core Inspections 23 Modules 3
Event Follow-ups 0
Violations 16 Inspectors 948 Inspection Hours 9
Notable Issues https://www.nrc.gov/about-nrc/contactus.html SAFETY OPERATIONS None RADIOLOGICAL CONTROLS None SAFEGUARDS None FACILITY SUPPORT None OTHER AREAS None 10
Plant Events No program adjustment warranted or ANI identified No NRC Identified Violations The NRC grouped the events across performance areas No cross-cutting issues No need for additional focus by the licensee or NRC at this time The NRC followed up on four events (three reportable)
No safety-significant issues No security-significant issues 11
https://www.nrc.gov/about-nrc/contactus.html Summary
- Westinghouse conducted activities safely and securely
- No Violations of Regulatory Compliance were identified
- NRC will conduct the core (routine) inspection program in the next performance assessment cycle (January 1, 2022 - December 31, 2023) 13
Westinghouse Remarks https://www.nrc.gov/about-nrc/contactus.html
NRC Response to https://www.nrc.gov/about-nrc/contactus.html
NRC Response to Mission Critical Functions:
Monitoring plant activities remotely/on-site through inspections and oversight Maintaining emergency response capabilities with Regional IRCs and HQ Limiting and risk-informing on-site inspections for region-based inspectors https://www.nrc.gov/about-nrc/contactus.html
Additional Actions:
Expanded use of telework Ongoing Review of Continuity of Operations Plan Coordinating actions with industry to minimize inspection schedule impacts while protecting inspectors and plant staff NRC Response to https://www.nrc.gov/about-nrc/contactus.html
Informal Question and Answer Session between the NRC and the Public https://www.nrc.gov/about-nrc/contactus.html
Closing Remarks https://www.nrc.gov/about-nrc/contactus.html
https://www.nrc.gov/about-nrc/contactus.html Please submit feedback by emailing Thomas.Vukovinsky@nrc.gov or Nicholas.Peterka@nrc.gov
List of Publicly Available Documents https://www.nrc.gov/about-nrc/contactus.html
- 2022 License Performance Review report 2022-005