ML22096A006 Reactor Pressure Vessel Inservice Inspection Requirements in the U.S.
Michael L. Benson U.S. Nuclear Regulatory Commission International ISI Workshop April 11-14, 2022 Virtual Workshop
- Inservice inspection requirements for U.S. nuclear power plants are set forth in Title 10 of the Code of Federal Regulations 50.55a (10 CFR 50.55a)
- American Society of Mechanical Engineers (ASME) Boiler
& Pressure Vessel Code,Section XI, Division 1 (BPV XI) is incorporated by reference (IBR) in 10 CFR 50.55a
- The rules of BPV XI, therefore, become law subject to conditions in 10 CFR 50.55a(b)(2) upon IBR 4/12/2022 2
Regulations vs. Consensus Standards
- General requirements applicable to all examination activities under BPV XI
- Programmatic in nature
- Interval dates and inspection periods
- Applicable Edition and Addenda of BPV XI
- An ISI interval is a time period during which all the examination requirements of BPV XI must be met (see IWA-2430(a))
Rules of BPV XI, Subsection IWA (2021 Edition)
- Examination requirements for ASME Class 1 components
- Table IWB-2500-1 provides a complete listing of components in scope of BPV XI and defines required method, extent, and frequency of the exam.
- Organized according to Examination Categories
- Each category is organized according to Item Numbers
- Figures in IWB illustrate applicable weld geometries and exam volumes 4/12/2022 4
Rules of BPV XI, Subsection IWB (2021 Edition)
- Examination Category B-A, Pressure Retaining Welds in Reactor Vessel
- Item Nos. B1.10-B1.12: vessel shell welds
- Item Nos. B1.20-B1.22: vessel head welds
- Item No. B1.30: shell-to-flange weld
- Item No. B1.40: head-to-flange weld
- Item No. B1.50-B1.51: repair welds 4/12/2022 5
Rules of BPV XI, Subsection IWB (2021 Edition)
- Examination Category B-D, Full Penetration Welded Nozzles in Vessels
- Item Nos. B3.90: nozzle-to-vessel welds
- Item Nos. B3.100: nozzle inner radius section 4/12/2022 6
Rules of BPV XI, Subsection IWB (2021 Edition)
- Circumferential and longitudinal reactor vessel shell welds
- Method: Volumetric exam
- Frequency: Once during the first ISI interval and each successive interval
- Extent: All welds, essentially 100% of defined volume
- Essentially 100%: IWA-2200(c) - greater than 90% of the defined volume 4/12/2022 7
BPV XI Rules for Items B1.10-B1.12 (2021 Edition)
- Circumferential and meridional reactor vessel head welds
- Method: Volumetric exam
- Frequency: Once during the first ISI interval and each successive interval
- Extent: Accessible length of all welds, essentially 100% of defined volume 4/12/2022 8
BPV XI Rules for Items B1.20-B1.22 (2021 Edition)
- Reactor vessel shell-to-flange weld
- Method: Volumetric exam
- Frequency: Once during the first ISI interval and each successive interval
- Extent: Essentially 100% of the defined volume 4/12/2022 9
BPV XI Rules for Item B1.30 (2021 Edition)
- Reactor vessel head-to-flange weld
- Method: Volumetric and surface exam
- Surface exam only may be used if a pervious volumetric exam did not detect a flaw that exceeds acceptance criteria
- Frequency: Once during the first ISI interval and each successive interval
- Extent: Essentially 100% of the defined volume 4/12/2022 10 BPV XI Rules for Item B1.40 (2021 Edition)
- Repair welds exceeding 10% of the nominal wall thickness
- Method: Volumetric and surface exam
- Surface exam only may be used if a previous volumetric exam did not detect a flaw that exceeds acceptance criteria
- Frequency: Once during the first ISI interval and each successive interval
- Extent: Essentially 100% of the defined volume 4/12/2022 11 BPV XI Rules for Items B1.50-B1.51 (2021 Edition)
- Nozzle-to-vessel welds
- Method: Volumetric
- Frequency: Once during the first ISI interval and each successive interval
- Extent: All nozzles, essentially 100% of the defined volume
- IWB-2500(f) allows 25% sample, as opposed to all nozzles 4/12/2022 12 BPV XI Rules for Item B3.90 (2021 Edition)
- Reactor vessel nozzle inside radius
- Method: Volumetric
- Frequency: Once during the first ISI interval and each successive interval
- Extent: All nozzles, essentially 100% of the defined volume
- IWB-2500(f) allows 25% sample, as opposed to all nozzles
- IWB-2500(g) allows visual exam in lieu of the volumetric exam, under certain conditions 4/12/2022 13 BPV XI Rules for Item B3.100 (2021 Edition)
- (xvi), (xviii), (xix), (xxii), and (xxiv) are miscellaneous conditions related to nondestructive examination
- (xxi)(B) conditions on use of IWB-2500(f) and (g)
- Requires a plant-specific evaluation
- Not permitted for plants with a renewed license
- Not permitted for newer plants licensed under 10 CFR 52 4/12/2022 14 Related Conditions in 10 CFR 50.55a(b)(2)
4/12/2022 16 Summary
- Conditions on ASME BPV XI in 10 CFR 50.55a(b)(2)
- Related items
- RPV-related Code Cases
- Alternatives under 10 CFR 50.55a(z)