ML22091A084

From kanterella
Jump to navigation Jump to search

NRR E-mail Capture - Braidwood and Byron - Withdrawal of Draft RAI Regarding Proposed Alternative for Various Pressurizer Welds (EPID L-2021-LLR-0035 and 0036)
ML22091A084
Person / Time
Site: Byron, Braidwood  Constellation icon.png
Issue date: 02/24/2022
From: Joel Wiebe
NRC/NRR/DORL/LPL3
To: Tom Loomis
Exelon Generation Co
References
L-2021-LLR-0035, L-2021-LLR-0036
Download: ML22091A084 (2)


Text

From: Wiebe, Joel Sent: Thursday, February 24, 2022 8:46 AM To: Loomis, Thomas R:(Exelon Nuclear)

Cc: Ballard, Brent; Mayer, Annie; Sreenivas, V; Salgado, Nancy

Subject:

Braidwood and Byron - Withdrawal of Draft RAI Regarding Proposed Alternative for Various Pressurizer Welds (EPID L-2021-LLR-0035 and 0036)

Hi Tom,

By email dated February 8, 2022, the U.S. Nuclear Regulatory Commission (NRC) sent a draft request for additional information (RAI) to Constellation Energy Group, LLC (CEG, the licensee) in response to your application dated May 12, 2021 (Agencywide Documents Access and Management System (ADAMS)

Accession No. ML21133A297). The licensee requested approval of proposed alternatives pursuant to Title 10 of the Code of Federal Regulations (10 CFR) 50.55a(z)(1) to the requirements of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code) for Braidwood Station Units 1 and 2 (Braidwood) and Bryon Station Units 1 and 2 (Byron).

The purpose of this email is to inform the licensee that the NRC has withdrawn this draft RAI for Braidwood and Byron.

The NRC staff is holding a public meeting (ADAMS Accession No. ML22053A171) via webinar on March 4, 2022 at 1:00pm to communicate staff perspectives on risk -informed modification of the Inservice Inspection Program to industry and the public. A revised draft RAI for this proposed alternative may be sent to the licensee following the public meeting.

Docket Nos. 50-454, 50-455, 50-456, and 50-457

Thank you, Joel

Hearing Identifier: NRR_DRMA Email Number: 1582

Mail Envelope Properties (MN2PR09MB4971B802725FB14CC1B2CF108B3D9)

Subject:

Braidwood and Byron - Withdrawal of Draft RAI Regarding Proposed Alternative for Various Pressurizer Welds (EPID L-2021-LLR-0035 and 0036)

Sent Date: 2/24/2022 8:45:48 AM Received Date: 2/24/2022 8:45:00 AM From: Wiebe, Joel

Created By: Joel.Wiebe@nrc.gov

Recipients:

"Ballard, Brent" <Brent.Ballard@nrc.gov>

Tracking Status: None "Mayer, Annie" <Andrea.Mayer@nrc.gov>

Tracking Status: None "Sreenivas, V" <V.Sreenivas@nrc.gov>

Tracking Status: None "Salgado, Nancy" <Nancy.Salgado@nrc.gov>

Tracking Status: None "Loomis, Thomas R:(Exelon Nuclear)" <thomas.loomis@constellation.com>

Tracking Status: None

Post Office: MN2PR09MB4971.namprd09.prod.outlook.com

Files Size Date & Time MESSAGE 1225 2/24/2022 8:45:00 AM

Options Priority: Normal Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date: