ML22083A210
| ML22083A210 | |
| Person / Time | |
|---|---|
| Site: | North Anna (NPF-7) |
| Issue date: | 03/24/2022 |
| From: | Ed Miller NRC/NRR/DORL/LPL2-1 |
| To: | Erica Combs Dominion Generation |
| References | |
| L-2021-LLR-0088 | |
| Download: ML22083A210 (3) | |
Text
From:
Miller, Ed Sent:
Thursday, March 24, 2022 1:56 PM To:
Erica.N.Combs@dominionenergy.com
Subject:
Draft RAI for N2-I4-LMT-003 Attachments:
Draft RAI for NA2 RR N2-14-LMT-003.docx Erica, Attached is the NRC staffs draft RAI for the subject request. The questions are being transmitted to you to determine 1) If the question clearly conveys the NRC information needs, 2)
Whether the regulatory basis for the question is clear, and 3) If the information has already been provided in existing docketed correspondence. Additionally, review of the draft question will allow you to determine whether you are able to support a 30 day response time. After youve had a chance to review, please let me know if you would like to have a clarification call. Thank you.
Ed Miller (301) 415-2481
Hearing Identifier:
NRR_DRMA Email Number:
1569 Mail Envelope Properties (SA1PR09MB74876E4F025D8F4BD81F1147E9199)
Subject:
Draft RAI for N2-I4-LMT-003 Sent Date:
3/24/2022 1:55:52 PM Received Date:
3/24/2022 1:55:00 PM From:
Miller, Ed Created By:
Ed.Miller@nrc.gov Recipients:
"Erica.N.Combs@dominionenergy.com" <Erica.N.Combs@dominionenergy.com>
Tracking Status: None Post Office:
SA1PR09MB7487.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 630 3/24/2022 1:55:00 PM Draft RAI for NA2 RR N2-14-LMT-003.docx 22855 Options Priority:
Normal Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
DRAFT REQUEST FOR ADDITIONAL INFORMATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELIEF REQUEST N2-14-LMT-003 FOURTH TEN YEAR INSERVICE INSPECTION INTERVAL VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNIT 2 DOCKET NO. 50-339 EPID: L-2021-LLR-0088 By letter dated December 13, 2021, (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21348A711), Virginia Electric and Power Company (the licensee),
submitted Relief Request (RR) N2-14-LMT-003 to the U.S. Nuclear Regulatory Commission (NRC) for the fourth Inservice Inspection (ISI) interval at North Anna Power Station Unit 2. In RR N2-14-LMT-003, the licensee requested relief from the examination coverage requirements of Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components, of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (ASME Code).
The NRC has determined that the following additional information is necessary to complete its review and make a regulatory decision.
- 1. What are the ASME code classes for welds 10, 19, and 8 in Section R2 Elements Subject to Intergranular or Transgranular Stress Corrosion Cracking of the RR N2 LMT-003?