From:
Bavol, Bruce Sent:
Monday, March 21, 2022 3:48 PM To:
RAI@nuscalepower.com Cc:
NuScale-SDA-720RAIsPEm Resource; Myers, Gregory; Norris, Rebecca; Tesfaye, Getachew; Cranston, Greg; Patton, Rebecca; tgriffith@nuscalepower.com; Dudek, Michael
Subject:
Final Request for Information eRAI 9899 (Non-Proprietary)
Attachments:
Final Request for Information eRAI 9899 (Non-Proprietary).pdf Good Morning, Attached please find NRC staffs request for additional information (RAI 9899) concerning the review of Licensing Topical Report TR-107522-P Rev 0, Applicability Range Extension of NSP4 Critical Heat Flux Correlation," (Agencywide Documents Access and Management System
[ADAMS] Accession Nos. ML21309A755 [proprietary] and ML21309A754 [nonproprietary]).
Please submit your technically correct and complete response by the agreed upon date to the NRC Document Control Desk.
If you have any questions, please feel free to contact me at 301-415-6715.
Thank you, Bruce M. Bavol Project Manager Office of Nuclear Reactor Regulation DNRL/NRLB Docket No.: 99902078
Hearing Identifier:
NuScale_SDA720_RAI_Public Email Number:
5 Mail Envelope Properties (SA1PR09MB7949FF5B510B61B10E7E9CAAEE169)
Subject:
Final Request for Information eRAI 9899 (Non-Proprietary)
Sent Date:
3/21/2022 3:47:30 PM Received Date:
3/21/2022 3:47:32 PM From:
Bavol, Bruce Created By:
Bruce.Bavol@nrc.gov Recipients:
"NuScale-SDA-720RAIsPEm Resource"
<NuScale-SDA-720RAIsPEm.Resource@usnrc.onmicrosoft.com>
Tracking Status: None "Myers, Gregory" <gmyers@nuscalepower.com>
Tracking Status: None "Norris, Rebecca" <RNorris@nuscalepower.com>
Tracking Status: None "Tesfaye, Getachew" <Getachew.Tesfaye@nrc.gov>
Tracking Status: None "Cranston, Greg" <Gregory.Cranston@nrc.gov>
Tracking Status: None "Patton, Rebecca" <Rebecca.Karas@nrc.gov>
Tracking Status: None "tgriffith@nuscalepower.com" <tgriffith@nuscalepower.com>
Tracking Status: None "Dudek, Michael" <Michael.Dudek@nrc.gov>
Tracking Status: None "RAI@nuscalepower.com" <RAI@nuscalepower.com>
Tracking Status: None Post Office:
SA1PR09MB7949.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 758 3/21/2022 3:47:32 PM Final Request for Information eRAI 9899 (Non-Proprietary).pdf 25704 Options Priority:
Normal Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
1 Request for Additional Information Issue Date: 03/14/2022 Application
Title:
Pre-Application Activities for NuScale SDA Application Operating Company: NuScale Docket No. 99902078 Review Section: NTR - NuScale Topical Report for SDA Application Section: TR-107522 Applicability Range Extension of NSP4 CHF Correlation RAI 9899 - QUESTIONS NTR-01 Regulatory Basis:
Title 10 of the Code of Federal Regulations (10 CFR) Part 52, Section 47 and Section 79 require a final safety analysis report (FSAR) to analyze the design and performance of the structures, systems, and components (SSCs). Safety evaluations, performed to support the FSAR, include accident analyses to demonstrate that specified acceptable fuel design limits (SAFDLs) are not exceeded during normal operation, including the effects of anticipated operational occurrences (AOOs).
GDC 10, Reactor design, which requires that the reactor core and associated coolant, control, and protection systems be designed with appropriate margin to assure that SAFDLs are not exceeded during any condition of normal operation, including the effects of AOOs.
Issue:
In Supplement 1 to TR-0116-21012-P-A, Revision 1, NuScale provided NSP4 predictions for ((. Request: (( }} in the same format as "Appendix A to Topical Report Entitled "Applicability Range Extension of NSP4 Critical Heat Flux Correlation: Supplement 1 to TR-0116-21012-P-A, Revision 1," TR-107522-P, Revision 0. NTR-02 Regulatory Basis: Title 10 of the Code of Federal Regulations (10 CFR) Part 52, Section 47 and Section 79 require a final safety analysis report (FSAR) to analyze the design and performance of the structures, systems, and components (SSCs). Safety evaluations, performed to support the FSAR, include accident analyses to demonstrate that specified acceptable fuel design limits (SAFDLs) are not exceeded during normal operation, including the effects of anticipated operational occurrences (AOOs). GDC 10, Reactor design, which requires that the reactor core and associated coolant, control, and protection systems be designed with appropriate margin to assure that SAFDLs are not exceeded during any condition of normal operation, including the effects of AOOs. Issue:
2 In their February 18, 2022, submittal of supplement information, "CHF Topical Supplement, February 3, 2022, Clarification Call Summary", NuScale ((
}}.
Request: ((
}}.}}