Text
ED20220034 Atlanta Corporate Headquarters 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092 Phone 770-447-1144 www.nacintl.com March 18, 2022 U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Attn:
Document Control Desk
Subject:
Submission of Responses to the Nuclear Regulatory Commissions (NRC) Request for Additional Information for the Request to Renew the NRC Certificate of Compliance No.
1025 for the NAC-MPC Cask System, Docket No. 72-1025 CAC/EPID Nos. 001028/L-2020-RNW-0031
References:
- 1.
ED20190141, Submission of a Request to Renew the U.S. Nuclear Regulatory Commission Certificate of Compliance No. 1025 for the NAC-MPC Cask System, December 18, 2019
- 2.
Request for Additional Information for the Technical Review of the Application for Renewal of the Certificate of Compliance No. 1025 (CAC/EPID NOS. 001028/L-2019-RNW-0029), March 23, 2021
- 3.
Submission of Responses to the Nuclear Regulatory Commissions (NRC)
Request for Additional Information for the Request to Renew the NRC Certificate of Compliance No. 1025 for the NAC-MPC Cask System, August 10, 2021
- 4.
Request for Additional Information for the Technical Review of the Application for Renewal of the Certificate of Compliance No. 1015 (CAC/EPID Nos. 001028/L-2020-RNW-0031), December 21, 2021 NAC International Inc. (NAC) hereby submits responses to the NRC Request for Additional Information (RAI) issued on December 21, 2021 (Reference 4). The NRC RAI (Reference 4) contained several questions that were common to both the NAC-UMS and NAC-MPC (Multi-Purpose Canister System) renewal applications. The responses to the NAC-UMS RAIs were submitted on March 3, 2022. This submittal package contains a copy of the non-proprietary responses to those NRC RAIs specific to the NAC-MPC System and can be found in Attachment 1 of this letter. There were no responses that were deemed proprietary in nature. Those Enclosures affected by the changes are being submitted in their entirety. Revision bars mark the text changes on the pages with changes.
Consistent with NAC administrative practice, this proposed FSAR revision is numbered to uniquely identify the applicable changed pages. Enclosure 3 contains a summary of the changes to the SAR revision. The headers of the FSAR pages with changes indicate the revision and the submittal month and year. Revision bars mark the FSAR text changes on the pages.
ED20220034 U.S. Nuclear Regulatory Commission March 18, 2022 Page 2 of 2 In accordance with NACs administrative practices, upon final acceptance of this application, the 19A, 21A, and 22A changed pages will be reformatted and incorporated into the next revision of the NAC-MPC FSAR.
If you have any comments or questions, please contact me on my direct line at 678-328-1236.
Sincerely, Wren Fowler Director, Licensing Engineering
Attachment:
Enclosures:
- 1. Application for Renewal of the NAC-MPC System CoC (22A)
- 2. Appendix A - Aging Management Programs (22A)
Wren Fowler Digitally signed by Wren Fowler Date: 2022.03.18 10:26:57 -04'00'