ML22066A992

From kanterella
Jump to navigation Jump to search

Letter to W Fowler Re Revision No. 72 of Certificate of Compliance No 9225 for the Model No NAC-LWT Transportation Package and Enclosure 2 Safety Evaluation Report
ML22066A992
Person / Time
Site: 07109225
Issue date: 03/22/2022
From: Yoira Diaz-Sanabria
Storage and Transportation Licensing Branch
To: Fowler W
NAC International
Nishka Devaser NMSS/DFM/STL 301-415-5196
Shared Package
ML22066A990 List:
References
EPID L-2021-LLA-0206
Download: ML22066A992 (3)


Text

OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Wren Fowler Licensing Manager NAC International 3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092

SUBJECT:

REVISION 72 OF CERTIFICATE OF COMPLIANCE NO. 9225 FOR THE MODEL NO. NAC-LWT PACKAGE

Dear Wren Fowler:

By application dated October 20, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21294A114) NAC International, Inc., requested a revision to the Certificate of Compliance (CoC or the certificate) No. 9225, for the Model No. NAC-LWT package.

The approval constitutes authority to use the package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of Title 49 of the Code of Federal Regulations (49 CFR) 173.471. Those on the attached list have been registered as users of the package under the general license provisions of 10 CFR 71.17 or 49 CFR 173.471.

If you have any questions regarding this certificate, please contact me or Nishka Devaser of my staff at (301) 415-5196.

Sincerely, Yoira K. Diaz-Sanabria, Chief Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9225 EPID No. L-2021-LLA-0206

Enclosures:

1. Certificate of Compliance No. 9225, Rev. No. 72 2.

Safety Evaluation Report 3.

Registered Users (non-public) cc w/encls. 1& 2: R. Boyle, Department of Transportation J. Shuler, U.S. Department of Energy c\\o L. F. Gelder Registered Users Upon Removal of, this letter and Enclosures 1& 2 are decontrolled.

March 17, 2022 Chen, Yen-Ju signing on behalf of Diaz-Sanabria, Yoira on 03/17/22

ML22066A990 (Pkg), ML22066A992 (Ltr & SER-Enc2)

ML22066A991 (encl 1), ML22066A993 (encl 3 non-public)

OFFICE:

NMSS\\DFM NMSS\\DFM NMSS\\DFM NMSS\\DFM NMSS\\DFM NMSS\\DFM NAME:

NDevaser SFigueroa OKhan DDunn TBoyce N.Devaser for YDiazSanabria DATE:

03/08/2022 03/08/2022 03/08/2022 03/08/2022 03/15/2022 03/16/2022 SAFETY EVALUATION REPORT Docket No. 71-9225 Model No. NAC-LWT Certificate of Compliance No. 71-9225 Revision 72 GENERAL EVALUATION By application dated October 20, 2021 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML21294A114) NAC International, Inc., (NAC or the applicant) requested a revision to the Certificate of Compliance (CoC or the certificate) No. 9225, for the Model No. NAC-LWT package. NAC requested an amendment to permit changes to the pressurized water reactor (PWR) Basket to provide additional fabrication flexibility.

Following the U.S. Nuclear Regulatory Commission staff review of the associated safety analysis report (SAR), the staff finds that the changes do not affect the ability of the package to meet the requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 71.

Packaging Drawings The applicant submitted one drawing that shows the PWR Basket assembled using a two-piece band on the NAC-LWT package.

LWT 315-40-10, Rev. 9 (Sheets 1 - 2)

PWR Basket MATERIALS EVALUATION The applicant provided a list of changes to the LWT Cask PWR Basket Safety Analysis Report, Sheets 1 and 2, Revision 9. The changes provided by the applicant included corrections to the drawing that are not associated with design changes to the packaging. The applicant included the option to fabricate Item 10 (Band) from two-piece construction with a complete joint penetration weld, which previously was one piece construction. The applicant included material yield and ultimate strength requirements for the two-piece Item 10. The applicant also made a revision to the liquid penetrant examination acceptance standard to include ASME Section III, Article NG-5350, as an option to the previous acceptance standard of ASME Section VIII, Division 1, Appendix 8.

The staff reviewed the changes to the drawing provided by the applicant. The staff determined that the editorial changes and corrections have no impact on the packaging design, material properties, or safety functions. Therefore, the staff determined that the editorial changes and corrections to the drawing were acceptable. The staff determined that the change to allow Item 10 to be fabricated with a welded two-piece construction was acceptable because the applicant included requirements for material properties of the optional construction that assure the safety function of this component. The staff determined that the inclusion of the optional acceptance standards for the penetrant testing were acceptable because the acceptance standards specified in ASME Section III, Article NG-5350, are conservative compared to the standards specified in ASME Section VIII, Div. 1, Appendix 8.

CONDITIONS The following changes have been made to the certificate:

Condition 3(b) has been revised to reflect the last date that the application was consolidated.

This was mistakenly not revised by staff when the application was consolidated in March 2020.

Condition No. 5(a)(3)(ii), Drawings, was updated to reflect the latest revision (revision 9) of drawing No. LWT 315-40-10, (Sheets 1 - 2), PWR Basket.

Condition No. 20 has been edited to specify the termination date of the previous revision of the certificate (revision 71).

The application date for this amendment was added to the REFERENCES section.

CONCLUSION Based on the statements and representations in the application, as supplemented, and the conditions listed above, the staff concludes that the Model No. NAC-LWT package design has been adequately described and evaluated, and that these changes do not affect the ability of the package to meet the requirements of 10 CFR Part 71.

Issued with Certificate of Compliance No. 9225, Revision No. 72.

ML22066A990; Ltr ML22066A992 OFFICE NMSS/DFM/STLB NMSS/DFM/STLB NMSS/DFM/MSB NMSS/DFM/MSB NAME NDevaser SFigueroa OKhan DDunn DATE Mar 8, 2022 Mar 8, 2022 Mar 8, 2022 Mar 8, 2022 OFFICE NMSS/DFM/MSB NMSS/DFM/STLB NAME TBoyce YDiaz-Sanabria YChen for DATE Mar 15, 2022 Mar 17, 2022