CONVERSATION RECORD NRC FORM 699 (03-2013)
U.S. NUCLEAR REGULATORY COMMISSION NRC FORM 699 (03-2013)
DATE OF SIGNATURE TYPE OF CONVERSATION NAME OF PERSON(S) CONTACTED OR IN CONTACT WITH YOU DATE OF CONTACT ORGANIZATION E-MAIL TELEPHONE INCOMING OUTGOING SUBJECT
SUMMARY
ACTION REQUIRED (IF ANY)
NAME OF PERSON DOCUMENTING CONVERSATION SIGNATURE Page 1 Continue on Page 2 E-MAIL ADDRESS Continue on Page 3 TELEPHONE NUMBER DOCKET NUMBER(S)
LICENSE NUMBER(S)
CONTROL NUMBER(S) of 02/22/2022 TN Americas LLC (TN)
Clarification Call regarding draft TN supplemental response to request for additional information (RAI) 10-1 for Certificate of Compliance (CoC) No. 1042 Amd. #3.
Participants:
TN: Glenn Mathues, Don Shaw, David Olson, Raheel Haroon, Hoi Yee Tom NRC: Christian Jacobs, Darrell Dunn, Omar Khan, Earl Love TN to provide revised responses and/or revised Safety Analysis Report (SAR) sections related to RAI 10-1 by February 25, 2022.
Glenn Mathues glenn.mathues@orano.group (410) 910-6538 72-1042 CoC 1042 EOS Amendment #3 2
02/23/2022
SUMMARY
- (Continued from page 1)
NRC FORM 699 (03-2013)
CONVERSATION RECORD (continued)
NRC FORM 699 (03-2013)
U.S. NUCLEAR REGULATORY COMMISSION Page 2 of A clarification call was held on February 22, 2022, with TN staff.
TN provided draft supplemental responses to RAI 10-1 (See attached enclosures: public and non-public proprietary versions).
NRC questioned whether the calibration block is representative to detect flaws mentioned in the RAI response?
TN responded that they have chosen and picked surfaces that are the most difficult/challenging to detect flaws.
NRC requested that TN provide an explanation in their response indicating the actual surface that TN is interested in, and how TN is going to conduct the measurement.
TN will provide an example (reflector #7 or #8 or #9) from the top or bottom notch, and an example (reflector #1 or #2 ) of one of the side drilled holes.
Any correspondence or transmittal of supplemental information should include the following:
CAC: 001028 Docket: 72-1042 EPID: L-2021-LLA-0055 2
ACTION REQUIRED (Continued from page 1)
NRC FORM 699 (03-2013)