Research Update:
Completion of Phase 1 Probabilistic Flood Hazard Assessment (PFHA) Research Office of Nuclear Regulatory Research PFHA Research Objectives Provide the technical basis for guidance for probabilistic assessment of external flooding hazards Support risk-informed licensing and oversight activities involving assessment of flooding hazards and potential consequences Develop resources, tools, and selected guidance
- See final slide for credits
Phase 1 (Technical Basis) Elements Phase 1 research focused on topics related to the technical basis for statistical and probabilistic modeling of selected flooding processes of interest at nuclear power plants and other commercial nuclear facilities:
- Climate and precipitation
- Mechanistic, statistical, and probabilistic modeling of
+ Riverine coastal flooding processes
+ Coastal flooding processes
- Combined flooding mechanisms
- Modeling frameworks
- Reliability of flood protection features and procedures The Phase 1 research leveraged contract technical support from other Federal agencies and private contractors, as well as subcontracts and grants to academic researchers, such as the following:
Climate
- First Annual Report: CONUS (PNNL-24868) https://www.osti.gov/biblio/1259942
- Second Annual Report: Southeast US (PNNL-26226 Rev 1) https://www.osti.gov/biblio/1593340
- Third Annual Report: Midwest US (PNNL-27452 Rev1) https://www.osti.gov/biblio/1524249
- Fourth Annual Report: Northeast US (PNNL-29079) https://www.osti.gov/biblio/1605280 The NRC and PNNL staff prepared four annual reports that summarize recent scientific findings about global and regional climate change, focusing on climatic elements that are relevant to NRC staff concerns on a regional level (i.e., increasing air and water temperatures, decreasing water availability, increasing frequency and intensity of storms and flooding, and sea-level rise).
- See final slide for credit
Precipitation Mure-Ravaud, et al. 2019a. Numerical reconstruction of the intense precipitation and moisture transport fields for six tropical cyclones affecting the eastern United States. https://www.sciencedirect.com/science/article/pii/S0048969719306734 Mure-Ravaud, et al. 2019b. Physically based storm transposition of four Atlantic tropical cyclones.
https://www.sciencedirect.com/science/article/pii/S0048969719306291 Kao, et al. 2020. Variability of precipitation areal reduction factors in the conterminous United States.
https://www.sciencedirect.com/science/article/pii/S2589915520300158 NUREG/CR-7247. Research to Develop Guidance on Extreme Precipitation Frequency Estimates in Orographic Regions (in publication).
NUREG/CR-7271. Application of Point Precipitation Frequency Estimates to Watersheds. https://www.nrc.gov/reading-rm/doc-collections/nuregs/contract/cr7271/index.html NUREG/CR-7278. Numerical Simulation of Local Intense Precipitation Processes (in publication).
NUREG/CR-7290. Convection-Permitting Modeling for Intense Precipitation Processes (in publication).
The NRC worked with other Federal agencies, national laboratories, and university researchers to investigate statistical and numerical simulation approaches for modeling extreme precipitation.
- See final slide for photo credit
Riverine Flooding USGS Scientific Investigations Report (SIR)-2017-5038. Application of At-Site Peak-Streamflow Frequency Analyses for Very Low Annual Exceedance Probabilities.
https://pubs.er.usgs.gov/publication/sir20175038 USGS SIR-2020-5065. Flood-Frequency Estimation for Very Low Annual Exceedance Probabilities Using Historical, Paleoflood, and Regional Information with Consideration of Nonstationarity. https://doi.org/10.3133/sir20205065 NRC Research Information Letter (RIL) 2022-04. Technical Basis for Extending Flood Frequency Curves Beyond Current Consensus Limits (in publication).
USGS SIR 2014-5207. Assessing inundation hazards to nuclear powerplant sites using geologically extended histories of riverine floods, tsunamis, and storm surges.
https://pubs.er.usgs.gov/publication/sir20145207 USGS SIR-2017-5052. Prehistoric floods on the Tennessee RiverAssessing the use of stratigraphic records of past floods for improved flood-frequency analysis.
https://doi.org/10.3133/sir20175052 USGS SIR-2020-5138. Improving Flood-Frequency Analysis with a 4,000-Year Record of Flooding on the Tennessee River near Chattanooga, Tennessee.
https://pubs.er.usgs.gov/publication/sir20205138 USGS Techniques and Methods Report 4-B6. Historical and Paleoflood Analyses for Probabilistic Flood-Hazard AssessmentsApproaches and Review Guidelines.
https://doi.org/10.3133/tm4B6 The NRC staffs research focused on statistical modeling methods and application of paleoflood hydrology approaches for estimating extreme riverine floods.
Coastal Flooding
- Engineer Research and Development Center (ERDC)-Coastal and Hydraulics Laboratory (CHL) SR-19-1. Quantification of Uncertainty in Probabilistic Storm Surge Models: Literature Review. https://erdc-library.erdc.dren.mil/xmlui/handle/11681/32295
- ERDC-CHL TR-19-4. Storm Recurrence Rate Models for Tropical Cyclones: Report 1 of a series on the Quantification of Uncertainties in Probabilistic Storm Surge Models. https://erdc-library.erdc.dren.mil/xmlui/handle/11681/32824
- ERDC-CHL Technical Report. Data, Models, and Methods for Defining Joint Probability of Storm Parameters and Generating Synthetic Storm Simulation Sets (in publication).
- ERDC-CHL Technical Report. Probabilistic Modeling of Numerical Surge Estimation Errors (in publication).
The NRC staff worked with the USACE to perform a detailed investigation of uncertainty in probabilistic modeling of storm surge due to hurricanes, tropical storms, and extratropical storms.
- See final slide for photo/figure credits
Flood Protection/Mitigation
- ORNL/TM-2019/1069. Current State-of-Practice in Dam Safety Risk Assessment. https://doi.org/10.2172/1592163
- NUREG/CR-7256. Effects of Environmental Conditions on Manual Actions for Flood Protection and Mitigation.
https://www.nrc.gov/reading-rm/doc-collections/nuregs/contract/cr7256/
- NUREG-2240. Flood Penetration Seal Testing Protocol Research (in publication).
- NUREG/CR-7279. Research to Develop Flood Barrier Testing Strategies for Nuclear Power Plants (in publication).
The NRC staff worked with national laboratories and private industry consultants to review the state-of-practice in dam safety risk assessment.
The NRC staff also investigated the feasibility of, and strategies for, testing of nuclear power plant flood barriers, and the effects of environmental conditions on flood response at nuclear power plants.
Combined Flooding Mechanisms
- ORNL/TM-2020/1447. Multi-Mechanism Flood Hazard Assessment: Critical Review of Current Practice and Approaches. https://doi.org/10.2172/1637939
- ORNL/TM-2021/2231. Multi-Mechanism Flood Hazard Assessment: Example Use Case Studies.
https://doi.org/10.2172/1826019
- NUREG/CR-7296. Multi-Mechanism Flood Hazard Assessment: Critical Review of Current Practice and Approaches and Example Use Case Studies (in publication).
The NRC staff worked with ORNL and UMD to review the state-of-practice in multimechanism flood hazard assessment (i.e., joint probability of flooding events due to coincident or correlated flooding processes). Case studies investigated application of copula-based and Bayesian-motivated approaches.
- Figure from ORNL/TM-22/1447
Modeling Frameworks ERDC/CHL TR-19-14. Probabilistic Flood Hazard Assessment Framework Development: Extreme Rainfall Analysis. https://erdc-library.erdc.dren.mil/jspui/handle/11681/33883 ERDC/CHL TR-20-7. Analysis of Snow Water Equivalent Annual Maxima in the Upper Connecticut River Basin Using a Max-Stable Spatial Process Model. https://erdc-library.erdc.dren.mil/jspui/handle/11681/36415 USACE/HEC Technical Report. Probabilistic Flood Hazard Assessment Framework: Riverine Flooding HEC-WAT Case Study (in publication).
NUREG/CR-7292. Structured Hazard Assessment Committee Process for Flooding (SHAC-F) for Local Intense Precipitation, Riverine, and Coastal Flooding (in publication).
NRC RIL 2022-03. A Simulation-Based Dynamic Analysis Approach for Modeling Plant Response to Flooding Events (in publication).
The NRC worked with
- USACE to investigate statistical and numerical simulations frameworks for flood hazard assessment
- PNNL to adapt the Senior Seismic Hazard Analysis Committee process for addressing uncertainty in flooding assessments
- INL to focus on a dynamic probabilistic risk assessment approach for flooding risk assessment
PFHA Research Workshops
- The NRC has organized and hosted seven Annual PFHA Research Workshops (2015-2022).
- Presenters have included NRC staff and contractors, as well as participants from Federal agencies, industry, and other domestic and international organizations.
- Presentations provide information on current activities, recent results, and perspectives on future research directions in flood hazard assessment, flood protection/mitigation, and flood risk assessment.
- The workshops have also included discussion of nonseismic external hazards such as extreme temperatures and high winds.
The NRC publishes PFHA workshop proceedings as NRC Research Information Letters (RILs):
1st-4th Annual Workshops: RIL 2020-01 5th Annual Workshop: RIL 2021-01 6th Annual Workshop: RIL 2022-02 7th Annual Workshop: In preparation Participation Typically 100-300 Participants NRC External NRC Participation External Participation Regions NMSS RES NRR Other International Academic Government Industry
Whats Next?
Phase 2Pilot Studies Three pilot studies are being conducted to demonstrate probabilistic flood hazard curve development for common flooding scenarios:
Local Intense Precipitation Flooding PFHA Pilot Studycompletion expected in second quarter 2022 Riverine Flooding PFHA Pilot Studystudy completed in January 2022 (report in publication)
Coastal Flooding PFHA Pilot Studycompletion expected in second quarter 2022 Phase 3Develop and Publish Regulatory Guidance Scope and format for regulatory guidance on PFHA methods is currently under discussion with internal stakeholders.
Publication of draft guidance for public comment is expected in fiscal year 2023.
Contact Information Joseph Kanney Joseph.Kanney@nrc.gov Elena Yegorova Elena.Yegorova@nrc.gov Thomas Aird Thomas.Aird@nrc.gov Photo/Figure Credits Photos/figures used are in the public domain with the following exceptions: